§ 13-2-304 — Sample collection
Code of Ordinances, City of Odessa, Texas (Includes legislation through Ord. No. 2026-22 adopted August 11, 2026) · Odessa City Code § 13-2-304
Corpus is an independent public-information project, not the official City of Odessa website. Stable reference: corpuslaw.us/code/9feeca17-2525-43a0-99cf-965feb5809c6
§ 13-2-304: Sample collection.
(a) The director will designate samples collection procedures and the number of samples to be collected over the course of discharge required to satisfy reporting requirements. Data submitted must be obtained through appropriate sampling and analysis performed during the period covered by the report, based on data that is representative of conditions occurring during the reporting period. (b) Except as indicated in subsections (c) and (d) below, the user must collect wastewater samples using 24-hour flow-proportional composite sampling techniques, unless time-proportional composite sampling or grab sampling is authorized by the director. Where time-proportional composites sampling or grab sampling is authorized by the city, the samples must be representative of the discharge. Using protocols (including appropriate preservation) specified by 40 CFR part 136 and appropriate EPA guidance, multiple grab samples collected during a 24-hour period may be composited in the field or at the laboratory prior to the analysis for cyanide, total phenols, and sulfides; for volatile organics and oil and grease, the samples may be composited in the laboratory. Composite samples for other parameters unaffected by the compositing procedures as documented in approved EPA methodologies may be authorized by the city, as appropriate. In addition, grab samples may be required to show compliance with instantaneous discharge limits. (c) Samples for oil and grease, temperature, pH, cyanide, phenols, sulfides, and volatile organic compounds must be obtained using grab collection techniques. (d) For sampling required in support of baseline monitoring and 90-day compliance reports required in sections 13-2-261 and 13-2-263, a minimum of four (4) grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide and volatile organic compounds for facilities for which historical sampling data do not exist; for facilities for which historical sampling data are available, the director may authorize a lower minimum. For the reports required by section 13-2-264, the user is required to collect the number of grab samples necessary to assess and assure compliance with applicable pretreatment standards and requirements. (e) Sample collection information, including but not limited to collection site, sample collector, type of sample, date and time of collection, and sample preservation shall be gathered and submitted along with the analytical data required by this division. Appropriately completed chain of custody forms must be submitted.
( Ordinance 2011-01 , sec. 1, adopted 1/11/11 )
Ask a question about Odessa law
Corpus searches the Odessa sections it holds and shows the ones that match, with their citations. Free, no sign-in.
