For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13-3-32 — Backflow prevention assembly installation and standards

Code of Ordinances, City of Odessa, Texas (Includes legislation through Ord. No. 2026-22 adopted August 11, 2026) · Odessa City Code § 13-3-32

Corpus is an independent public-information project, not the official City of Odessa website. Stable reference: corpuslaw.us/code/00f3b612-05b4-400c-80cc-12260439bff9

§ 13-3-32: Backflow prevention assembly installation and standards.

(a) Generally. (1) New installations. (A) New, replacement, or reconditioned backflow prevention assemblies shall be installed in accordance with the currently adopted plumbing code, as amended. (B) Prior to installation, the person must obtain a plumbing permit. (C) Prior to issuance of a certificate of occupancy, a completed test and maintenance report must be submitted to the utility for any connection requiring a testable backflow prevention assembly. Documentation of an approved air gap can be substituted where applicable. (2) High health hazard installations. (A) Only approved backflow prevention assemblies installed at the meter can be used at high health hazard applications unless a variance is obtained from the director. Variances will be based on conditions such as type of hazard(s), complexity of facility plumbing, potential for future plumbing connections, and others as deemed appropriate. (B) The director may require a secondary assembly if deemed necessary to protect the public water supply from the failure of or allow maintenance of the primary backflow prevention assembly. (3) Other installations. (A) An approved backflow prevention assembly shall be installed to protect the potable water system from contamination or pollution when such system is connected to any automatic fire protection system, standpipe system, or privately owned fire hydrants. (B) Installation of a reduced pressure backflow prevention assembly shall be required on any meter connected to the public potable water system for water appropriation from fire hydrants unless an approved air gap is authorized. Only meters and backflow prevention assemblies approved by the director can be used to obtain water from a fire hydrant. (4) Wholesale customers. Any customer purchasing water for the purpose of resale or distribution shall: (A) Install an air gap separation or a reduced pressure backflow assembly at the service connection; or (B) Implement a plumbing inspection and cross-connection control program approved by the director which is not less restrictive than that of the city and provide annual program records to the director for review and audit. (5) Government customers. Any premises owned, operated, or occupied by a state, federal, county, city, or foreign government or agency refusing to comply with the provisions of this article shall install a reduced/pressure backflow prevention assembly at each service connection. (6) Water hauling vehicles. Water hauling vehicles obtaining water from a connection to the public potable water system maintained by the city shall have an approved air gap separation or a reduced pressure backflow prevention assembly installed permanently on the vehicle, or, if connected by a fire hydrant meter, installed on the fire hydrant meter. This assembly shall be registered with the utility and certified for operation annually. (b) Compliance by existing customers. (1) The premises owner, customer or designated representative of any facility which is determined to have an unprotected or improperly installed high health hazard connection(s) must comply with subsection (a) of this section within sixty (60) days upon notification by the director unless the director determines that circumstances exist which require installation within a shorter time frame. Documentation of the installation and testing shall be submitted as defined in sections 13-3-33 and 13-3-36. (2) The premises owner, customer, or designated representative of any facility which is determined to have an unprotected non-health hazard connection must install an approved assembly immediately downstream of the city’s meter on a schedule determined by the director. Documentation of the installation and testing shall be submitted as defined in sections 13-3-33 and 13-3-36. (3) The premises owner, customer or designated representative shall have all testable backflow prevention assemblies which are currently installed certified for operation by a certified backflow prevention assembly tester on an annual basis. If the assembly has not been certified for operation within the last year, the assembly must be tested and, if required, repaired, and the documentation submitted to the director within sixty (60) days upon notification by the director or on a schedule approved by the director.

( Ordinance 99-61 , sec. 1, adopted 11/23/99 ; 1957 Code, sec. 21-38 )

Ask a question about Odessa law

Corpus searches the Odessa sections it holds and shows the ones that match, with their citations. Free, no sign-in.