§ 14-20-9: Building interface - commercial.

(a) Minimum glazing at the ground level. (1) Facades along planned street plaza or open space (public or private) shall be glazed with no less than 50% of the ground story measured between the ground and 12 feet above the ground. (2) Facades along all other frontages shall be glazed with no less than 30% of the ground story measured between the ground and 12 feet above the ground. (b) Glass transparency. All glass shall be transparent with a maximum 15% reflectivity. Any window tinting and graphics that create a permanent opaque or translucent condition are prohibited, except for allowed signage. (c) Setback landscape/hardscape. Landscaping shall be required in accordance with the adopted Landscape Ordinance 2016-19 and the setback area shall be available for dining and furnishing. (d) Shading of private and public frontage. In addition to shade provided by streets trees where they are provided, shading of the private and public frontage can be achieved through the combination of an awning frontage. [image]

( Ordinance 2019-08 adopted 2/26/19 )