Sec. 16-84. - Return air.

Return air shall be obtained from an approved interior location of the same building. Return air shall be taken from each level of a multi-story house. If an air conditioner or heater serves only one (1) specific area, return air shall be returned from that area to the unit serving it. A return air duct or chase shall have at least: Tonnage | Duct Size | Duct Size Square Inches 1 | 10" | 78.5 1½ | 12" | 113.4 2 | 14" | 153.86 2½ | 16" | 200.96 3 | 18" | 254.34 3½ | 18" | 254.34 4 | 20" | 314.0 5 | 2-16" | 380 Return air grills shall not be smaller than ten (10) square inches of net free area for every thousand BTU's of air conditioning. Return air shall not be obtained from the following locations: (a) Where it will pick-up objectionable odors, fumes, or flammable vapors. (b) A hazardous location. (c) An unsanitary location. (d) An area having a volume less than fifty (50) per cent of the entire volume served by the supply air system, unless there is a permanent communicating opening to areas having a volume equal to the required fifty (50) per cent. Appropriately sized transfer grills or door undercuts may be used to provide the required openings, as long as calculations are provided to the authority having jurisdiction. (e) A mechanical room with gas fired equipment. (f) A room or space containing fuel burning equipment. Exceptions: (1) Fire places, decorative appliances. (2) A listed vented wall furnace. (3) The return air inlet shall not be within ten (10) feet of any appliance fire box, draft diverter, or gas burning appliance in the same room or space. (g) A closet, bathroom, toilet room, or kitchen. (h) Within four (4) feet of an air supply register. (i) A corridor, exit passageway, or exit enclosure required by the building code to be of fire, or smoke resistive construction, unless sprinkled. (j) A dwelling unit, guest room, or patient room other than the room in which the air originates.

(Ord. No. 17-009, § 1(Exh. A), 1-17-17)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.