For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9-189 — Specific standards

Code of Ordinances of the City of Pasadena, Texas (Supp. No. 33, Update 2: codified through Ordinance No. 2026-143, enacted September 1, 2026) · Pasadena City Code § 9-189

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/af764561-cb3b-4a01-a7c9-4922fc9389c0

Sec. 9-189. - Specific standards.

In all areas of the city, except those covered by section 9-190 (coastal high hazard), the following provisions apply: (1) New construction or substantial improvement of any structure shall have the lowest floor, including the basement, garage, mechanical, electrical and HVAC equipment elevated to the following: a. For curb and gutter streets, a minimum of one (1) foot above the centerline of all adjacent streets at the midpoint of the lot, or meet the 500-year flood elevation as determined from the effective FIS using City of Pasadena benchmarks and correcting for latest NAVD leveling, whichever is higher. (Contact city for latest NAVD leveling.) b. Open ditch street one (1) foot above the centerline of the street at the midpoint of the lot, or meet the 500-year flood elevation as determined from the effective FIS, whichever is higher. c. For structures within two hundred (200) feet of the floodway a minimum elevation of two (2) feet above the 500-year flood elevation as determined from the effective FIS, or subsection a. or b. above, whichever is higher. (2) A registered professional engineer, or registered public surveyor shall submit certification to the floodplain administrator on forms provided by him that the standard of section 9-186(a)(1) is satisfied with regard to section 9-189(a). (3) Nonresidential construction. New construction and improvements of any commercial, industrial or other nonresidential structure shall either have the lowest floor (including basement) elevated to meet the 500-year flood elevation as determined from the effective FIS or, together with attendant utility and sanitary facilities, to be designed so that below the 500-year flood elevation the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this subsection. A record of such certification which includes the specific elevation (in relation to mean sea level) to which such structures are floodproofed shall be maintained by the floodplain administrator. (4) Nonresidential Enclosures. New construction and substantial improvements, with fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: a. A minimum of two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding shall be provided on two separate exterior walls. b. The bottom of all openings shall be no higher than one (1) foot above grade. c. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. (5) Manufactured homes. a. Require that all manufactured homes to be placed within zone A, shall be installed using methods and practices which minimize flood damage. For the purpose of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. b. Require that manufactured homes that are placed within zones A1-30, AH, AE and Shaded or Unshaded X on the community's FIRM on sites: (i) outside of a manufactured home park or subdivision, (ii) in a new manufactured home park or subdivision, or (iii) in an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as a result of a flood, be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated to one (1) foot above the 500-year flood elevation as determined from the effective FIS and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. c. Require that manufactured homes be placed on sites in an existing manufactured home park or subdivision with zones A1-30, AH, AE and Shaded or Unshaded X on the community's FIRM that are not subject to the provisions of subsection (4) of this section be elevated so that either: 1. The lowest floor of the manufactured home is one (1) foot above the 500-year flood elevation as determined by the effective FIS; and 2. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than thirty-six (36) inches in height above grade and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. d. Manufactured homes or new manufactured home parks will not be permitted within two hundred (200) feet of a designated floodway. (6) Recreational vehicles. Require that recreational vehicles placed on sites within zones A1, A30, AH, and AE on the community's FIRM either: (i) be on the site for fewer than one hundred eighty (180) consecutive days; (ii) be fully licensed and ready for highway use; or (iii) meet the permit requirements of this chapter, and the elevation and anchoring requirements for "manufactured homes" in paragraph (d) of this section. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions. (7) Critical facilities. There shall be no critical facilities constructed in the 100-year (one (1) percent) flood zone and to the extent possible no critical facilities within the limits of the 500-year flood zone (Shaded X) and any A zone a. An approved letter of map revision is required before a construction permit will be issued for the development if located in the 100-year flood zone. b. If only the building is removed from the 100-year flood zone, an emergency evacuation plan sealed by a registered professional is required. c. Should there be no feasible alternative site other than within the 500-year flood zone (Shaded X), the lowest floor must be elevated to three (3) feet or move above the 500-year flood elevation as determined from the effective FIS, or twenty-four (24) inches above the centerline of all adjacent streets at the midpoint of the lot, whichever is greater. d. Access routes elevated to or above the level of the base flood shall be provided to all critical facilities to the extent possible. Where it is not possible, an emergency evacuation plan sealed by a registered professional is required. (8) Floodplain storage capacity. Fill placed within the 100-year (one (1) percent) or 500-year (0.2 percent) (Shaded X) flood zones shall be mitigated on a 1:1 basis on the developing site such that no flood storage capacity is lost. (9) Mandatory disclosure. Property located within the 100-year (one (1) percent) flood zone must be disclosed as "flood prone" for any property sale. (10) Floodways located within areas of special flood hazard established in section 9-178 are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles and erosion potential, the following provisions shall apply: a. Encroachments are prohibited, including fill, grading, paving, new construction or expansion, substantial improvements and any other development or improvements. (11) Upon application of all building permits, there shall be submitted the approved floodplain development permit with approved plans, a site plan showing to scale, the size and location of all proposed construction and all existing structures of the site, distances from all lot lines, building lines, building setbacks, and all easements and/or rights-of-way, and show the elevation of the lowest floor and the centerline of the street at the centerline of the lot. In order to obtain a permit, it will also be a requirement to prepare and submit for approval a drainage plan which: (1) provides such means as are appropriate and necessary to prevent impoundment or diversion of the natural flow of surface water of the adjoining property, (2) provides that all of the storm water from the adjoining property which may have previously flowed across the subject property resulting from a five-year storm event will drain into the city storm water drainage system, (3) must maintain positive drainage on residential lots as originally designed and approved by director from rear to the front with drainage along the property lines into the storm system, all landscaping and fill for foundation shall accommodate the original drainage design, (4) commercial property including residential property used in any form as commercial or converted to commercial use shall internally collect all drainage from entire site including all roof drains and down spouts into a storm sewer system and connect this system to the city storm sewer system with reinforced concrete pipe, no sheet flow across property lines shall be allowed. Internal collection shall be provided along the property lines. Implementation of the drainage plan is required before a certificate of occupancy can be issued. Underground drainage systems crossing commercial property lines may be allowed if located in a dedicated easement and approved by the floodplain administrator. (12) The construction or improvements permitted under sections 9-188, 9-189, 9-190 and 9-191 shall be designed and constructed so as to provide positive drainage away from the structure(s) placed upon the site, and, in addition, provisions shall be made to contain and discharge storm water from the site so as not to interfere with or harm adjoining properties or disrupt or impound the natural flow of surface waters from adjoining properties. (13) Prior to request for top of form inspection, a building under construction elevation certificate signed and sealed by a State of Texas registered land surveyor or engineer shall be submitted to the floodplain manager. Elevation certificates shall include item (11) above and the established centerline elevations of all adjacent streets, base flood elevation, top of the form elevation and a topography of the entire site, and show the elevation of the lowest floor to be constructed in accordance with the provisions of section 9-189(1) hereof. All elevation certificates shall include in the comments section, the benchmark used with description of the location and centerline elevations of all adjacent streets. (14) Standards for areas of shallow flooding (AO/AH zones). Located within the areas of special flood hazard established in section 9-178, are areas designated as shallow flooding. These areas have special flood hazards associated with flood depths of one (1) to three (3) feet where a clearly defined channel does not exist, where the path of flooding is unpredictable, and where velocity flow may be evident. Such flooding is characterized by ponding or sheet flow; therefore, the following provisions apply: a. All new construction and substantial improvements of residential structures must have the lowest floor (including basement and garage) elevated above to at least three (3) feet above the depth number specified in feet on the community's FIRM (at least six (6) feet if no depth number is specified) or together with attendant utility and sanitary facilities be designed so that below the base specified flood depth in an AO zone, or below the base flood elevation in an AH zone, level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads of effects of buoyancy. b. A registered professional engineer or architect shall submit a certification to the Floodplain Administrator that the standards of this section, as proposed in section 9-186 are satisfied. c. Require within zones AH or AO adequate drainage paths around structures on slopes, to guide flood waters around and away from proposed structures.

(Ord. No. 20-186, § 1(Exh. 1), 1-5-21)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.