For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 1.30 — LI limited industrial district

Code of Ordinances of the City of Pharr, Texas (Codified through Ordinance No. O-2025-35, adopted September 15, 2025. (Supp. No. 44)) · Pharr Code of Ordinances § 1.30

Corpus is an independent public-information project, not the official City of Pharr website. Stable reference: corpuslaw.us/code/7db59abe-8d3e-4eac-84c4-b3a3bc269e14

Sec. 1.30. - LI limited industrial district.

A. Purpose: 1. Industrial development represents a substantial part of the economic base at Pharr, and more is desired. The rapidly changing variety of industry found in Pharr and the development of modern technology make it appropriate and desirable to provide for standards of industrial performance rather than to attempt to categorize by name. The purpose of this district is to create a limited industrial zone that provides for the modern type of industrial uses or industrial park. With the exception of hazardous materials manufacture, this zone allows the same uses as the HI, heavy industrial district. Limitations are placed on the uses in this district to significantly restrict the outside activities and storage of materials, noise, vibration, smoke, pollution, fire and explosive hazard, glare and any other potentially blighting influences. These limitations create a zone that could be considered the "highest and cleanest" industrial zone. 2. This zone is intended for industrial parks and larger, cleaner types of industries. The manufacturing uses should be conducted within a totally enclosed building. Any activities conducted outside should be screened and buffered, and no external effects such as excessive noise or odor should extend beyond the property lines. The sites for such uses are typically a minimum of two acres and average five to ten acres, with a significant amount of land dedicated to landscaping. 3. Because this is a limited industrial zone with substantial screening and buffering requirements, limited industrial uses are suitable for high-visibility locations such as along the freeway, or within a reasonable distance of residential areas. Residential uses should be discouraged from locating within the industrial district to protect the industries from residential complaints. 4. Areas should not be zoned to this usage unless they are located on or close to arterials capable of carrying commercial and truck traffic. They should be located close to major truck routes. Internal streets in such developments should be sized and strengthened to accommodate truck traffic. Each industry should work with the city to make sure the water pressure and capacity is adequate to provide fire protection for that particular industry before such industry is developed. Industries should also be required to prove that the water, wastewater, and drainage capacity is adequate before they are allowed to develop. B. Permitted uses: 1. Any of the following uses when the manufacturing, compounding, or processing of previously prepared materials are conducted wholly within a completely enclosed building. That portion of the land used for open storage facilities for materials or equipment used in the manufacturing, compounding or processing or for truck loading and unloading shall be totally obscured by a wall on those sides abutting a residentially zoned district, or an OP, NC, or C-2 district. a. The manufacturing, compounding, processing, packaging or treatment of such products as bakery goods, candy, cosmetics, pharmaceutical, toiletries, food products, hardware and cutlery; b. The manufacturing, compounding, assembling or treatment of articles or merchandise from the following previously prepared materials: bone, canvas, cellophane, cloth, cork, feathers, felt, fiber, fur, glass, hair, horn, leather, paper, plastics, precious or semiprecious metals or stones, sheetmetal (excluding saw and planning mills) and yarns; c. The manufacture of pottery and figurines or other similar ceramic products using only previously pulverized clay, and kilns fired only by electricity or gas; d. Manufacture of musical instruments, toys, novelties, and metal or rubber stamps, or other small molded rubber products; e. Manufacture or assembly of electrical appliances, electronic instruments and devices, radios, and phonographs; f. Laboratories—Experimental, film or testing; g. Manufacture and repair of electric or neon signs, sheetmetal products, including heating and ventilating equipment, cornices, eaves and the like; h. Tool, dye, gauge and machine shops; i. All public utilities, including buildings, necessary structures, storage yards and other related uses; j. Any retail business, personal services, professional services, or business services; k. Office buildings and accessory uses; l. Restaurants and drive-in businesses; m. Gasoline service stations, or retail outlets, where gasoline products are sold; n. Automotive and other repair services, excluding wrecking yards; o. Warehousing and storage; p. Any wholesale trades conducted in an enclosed building; q. Agricultural uses unplatted land in accordance with all other ordinances; r. Other uses of a similar and no more objectionable character to those principal uses permitted subject to any and all provisions of ordinance relating to the use of property within the City of Pharr. 2. Accessory structures and uses customarily related to the above principal uses authorized in this district, including the residence for a night watchman or caretaker employed on the premises. 3. Amusement parks, circus or carnival grounds, commercial amusements or recreational developments or tents or other temporary structures used for meetings, in accordance with all other applicable ordinances, and located more than 300 feet from the nearest residentially zoned land. C. Conditional uses (require use permits, see article III): 1. A portable building used for a night watchman which is not larger than 200 square feet. 2. Commercial uses that involve outside storage of materials and equipment and/or outside operations and/or with business hours between the hours of 7:00 p.m. to 7:00 a.m. D. Prohibited uses: 1. Any manufacturing use that involves the use and/or storage of substantial amounts of hazardous or flammable materials, such as petroleum products, that in the opinion of the fire marshal is a potential hazard. 2. Any building erected or land used for other than one or more of the preceding specified uses. 3. Any use of property that does not meet the required minimum lot size; front, side and rear yard dimension; and/or lot width; or exceeds the maximum height, building coverage or density per gross acre as required. 4. Any use that exceeds the performance standards listed in article VIII, or whose external effects create excessive noise, vibration, odor, smoke, pollution, or glare extending beyond the property line. Complaints under this section shall be served by the director of planning and complaints filed with the municipal judge if the director of planning determines that there is probable cause to believe a violation of the subsection as alleged exists. E. Area requirements: 1. Minimum site size, two acres. 2. Minimum site frontage on a public street, 100 feet. 3. Minimum site depth, 200 feet. 4. Minimum depth of front setback, 20 feet or equal to one-third the street right-of-way width on which the property fronts, plus one-half the building height over 36 feet with a 50-foot maximum, whichever is greater. 5. Minimum width of side setback: a. With or without fire-retardant wall, 15 feet plus half the building height over 36 feet, but in no case shall more than a 50-foot side setback be required. b. Abutting nonresidentially zoned property, 30 feet plus half the building height over 36 feet, but in no case shall more than a 50-foot side setback be required. 6. Minimum depth of rear setback: a. Abutting nonresidentially zoned property, fire-retardant wall or alley separating, 15 feet plus half the building height over 36 feet, but in no case shall more than a 50-foot rear setback be required. b. Abutting residential property, 30 feet plus half the building height over 36 feet, but in no case shall more than a 50-foot rear setback be required. 7. Minimum distance between detached buildings on the same lot or parcel of land: a. Without fire-retardant wall, 15 feet plus half the building height over 36 feet, but in no case shall more than a 50-foot distance between detached buildings be required. b. With fire-retardant wall, zero feet plus half the building height over 36 feet, but in no case shall more than a 50-foot distance between detached buildings be required. 8. Maximum building coverage as a percentage of lot area, 60 percent. 9. Maximum amount of impervious coverage as a percentage of lot area, 80 percent. 10. Minimum amount of landscape areas as a percentage of lot area, 20 percent. 11. Maximum floor area ratio, 2:1. 12. Maximum height of structures, 36 feet or four feet for each one foot of setback from the closest property line, whichever is greater. 13. Minimum number off-street parking spaces required, see "Off-Street Parking," article IV. 14. Maximum number of entrances and/or exits: a. Arterial streets, one per site per each 200 feet of street frontage. b. Collector streets, one per site per each 100 feet of street frontage. c. Local streets, one per site per each 50 feet of street frontage. 15. Lots with nonresidential uses that have a side or rear contiguous to or separated only by an alley, easement or street, from any residential district must be separated from such district by a buffer as defined. 16. The building code may impose more restrictive area requirements, depending on the size, use and construction of the structures. See article VII for further clarification, exceptions and modification.

(Ord. No. 89-22, § 1, 8-1-89; Ord. No. 89-41, § 2, 10-3-89; Ord. No. O-91-49, § 1, 11-6-91; Ord. No. O-93-22, § 4, 8-17-93)

Ask a question about Pharr law

Corpus searches the Pharr sections it holds and shows the ones that match, with their citations. Free, no sign-in.