§ 22-579 — Backflow prevention methods and devices
Code of Ordinances of the City of Pharr, Texas (Codified through Ordinance No. O-2025-35, adopted September 15, 2025. (Supp. No. 44)) · Pharr Code of Ordinances § 22-579
Corpus is an independent public-information project, not the official City of Pharr website. Stable reference: corpuslaw.us/code/160fff51-beb8-4e21-b1b1-1c360797a45d
Sec. 22-579. - Backflow prevention methods and devices.
(a) Any irrigation system that is connected to the potable water supply must be connected through a backflow prevention method approved by the Texas Commission on Environmental Quality (TCEQ). The backflow prevention device must comply with the International Plumbing Code and be certified by the American Society of Sanitary Engineers; or the Foundation for Cross-Connection Control and Hydraulic Research, University of Southern California; or any other laboratory that has equivalent capabilities for both the laboratory and field evaluation of backflow prevention assemblies. The backflow prevention device must be installed in accordance with the laboratory approval standards or if the approval does not include specific installation information, the manufacturer's current published recommendations. (b) If conditions that present a health hazard exist, one of the following methods must be used to prevent backflow: (1) An air gap may be used if: a. There is an unobstructed physical separation; and b. The distance from the lowest point of the water supply outlet to the flood rim of the fixture or assembly into which the outlet discharges is at least one inch or twice the diameter of the water supply outlet, whichever is greater. (2) Reduced pressure principle backflow prevention assemblies may be used if: a. The device is installed at a minimum of 12 inches above ground in a location that will ensure that the assembly will not be submerged; and b. Drainage is provided for any water that may be discharged through the assembly relief valve. (3) Pressure vacuum breakers may be used if: a. No back-pressure condition will occur; and b. The device is installed at a minimum of 12 inches above any downstream piping and the highest downstream opening. Pop-up sprinklers are measured from the retracted position from the top of the sprinkler. (4) Atmospheric vacuum breakers may be used if: a. No back-pressure will be present; b. There are no shutoff valves downstream from the atmospheric vacuum breaker; c. The device is installed at a minimum of six inches above any downstream piping and the highest downstream opening. Pop-up sprinklers are measured from the retracted position from the top of the sprinkler; d. There is no continuous pressure on the supply side of the atmospheric vacuum breaker for more than 12 hours in any 24-hour period; and e. A separate atmospheric vacuum breaker is installed on the discharge side of each irrigation control valve, between the valve and all the emission devices that the valve controls. (c) Backflow prevention devices used in applications designated as health hazards must be tested upon installation and annually thereafter. (d) If an existing irrigation system without a backflow-prevention assembly requires major maintenance, alteration, repair, or service, the system must be connected to the potable water supply through an approved, properly installed backflow prevention method before any major maintenance, alteration, repair, or service is performed. (e) The irrigator shall ensure the backflow prevention device is tested by a licensed backflow prevention assembly tester prior to being placed in service and the test results provided to the local water purveyor and the irrigation system's owner or owner's representative within ten business days of testing of the backflow prevention device.
(Ord. No. O-2009-24, § 1, 7-21-09)
Ask a question about Pharr law
Corpus searches the Pharr sections it holds and shows the ones that match, with their citations. Free, no sign-in.