Sec. 21-362. - Grease traps.

(a) New grease traps. (1) A grease trap shall be installed, operated, and maintained in accordance with the manufacturer's recommendations, this article, chapter 9 of this Code of Ordinances, or the City of Plano Plumbing Code, whichever is most restrictive, unless a variance has been approved by the director. (2) A person that performs food preparation activity at a food processing plant and/or food service facility shall install and maintain a grease trap in accordance with this article. (3) An operator of a grease trap shall install and maintain a sample port in compliance with written specifications for installation of the sample port obtained by the operator from the approving authority. (b) Existing grease traps. (1) Existing grease traps shall be operated and maintained in accordance with manufacturer's recommendations, this article, chapter 9 of this Code of Ordinances, or City of Plano Plumbing Code, whichever is most restrictive, unless a variance has been approved by the director. (2) If notified by the approving authority that a grease trap is not functioning properly in violation of federal, state, and/or local standards or regulations, said person shall install and maintain an approved grease trap and sample port. (3) A person that performs food preparation activity at an existing food processing plant and/or food service facility shall be required to install and maintain a grease trap in accordance with this article. (c) Responsibility. (1) A person generating liquid waste shall: a. Install a grease trap as required by this article; b. Maintain the grease trap in good repair and sanitary condition; c. Not install or use any system, process, or pretreatment or alter the design or function of a grease trap, unless approved by the director, including, but not limited to, the use of enzymes, bacteria, or other additives; d. Supervise the proper cleaning and complete removal of the contents of the trap; e. Immediately report spills and accidents involving liquid waste to the approving authority by phone or email; f. Clean up spills immediately; g. Abate unsanitary conditions immediately; h. Dispose of material used for abatement in a timely manner and by means approved by the director; i. Protect the MS4 and the environment from discharges of liquid waste, washwater, and other contaminants caused by spill, overflow, or the remediation of spill or overflow; and j. Not discharge waste of any kind into the MS4. (d) Trap evacuation. (1) Grease traps shall be evacuated and cleaned as required by the following sections to prevent accumulation of sediment or floating material that would impair the efficiency of the grease trap, to ensure the discharge is in compliance with local discharge limits, and to ensure no visible grease is observed in discharge. (2) Grease traps shall be completely evacuated at a minimum of every ninety (90) days, or more frequently if one (1) of the following conditions apply and written notice has been given to the operator by the approving authority: a. Twenty-five (25) percent or more of the wetted height of the grease trap, as measured from the bottom of the device to the invert of the outlet pipe, contains floating materials, sediment, oils, or greases; or b. The discharge exceeds local limits; or c. There is a history of noncompliance; or d. The director determines more frequent service, a single event service, or scheduled service is necessary for the proper operation of the grease trap. (3) Each grease trap shall be fully evacuated unless the trap volume is greater than the tank capacity on the vacuum truck in which case the transporter shall arrange for additional transportation capacity so the trap is fully evacuated within a twenty-four (24) hour period, in accordance with 30 Texas Administrative Code, chapter 312, section 312.143, as amended. (4) If a person ceases operation of a grease trap, the person is required to pump the trap before abandoning the operation. (5) A person that generates liquid waste shall not allow hazardous waste or liquid waste in combination with hazardous waste to be removed from a premises by a liquid waste transporter operating under a city permit. Removal of hazardous waste shall only be performed by an industrial hazardous waste hauler registered with the state. (6) When liquid waste is picked up, a person representing the operator or owner shall verify the accuracy of the trip ticket provided by the transporter. (7) A person that generates liquid waste shall maintain a copy of all trip tickets for a period of no less than three (3) years at the premises of generation. (8) All trip tickets shall be available for review upon request of the director. (e) Variances. (1) Any person may submit to the director a written request for a variance from this article.

(Ord. No. 2018-10-2, § I, 10-8-18, eff. 1-1-19)

Ask a question about Plano law

Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.