§ 6-254 — Deletions, additions, amendments
Code of Ordinances, City of Plano, Texas (Supp. No. 153: codified through Ordinance No. 2025-10-2, adopted October 13, 2025) · Plano City Code § 6-254
Corpus is an independent public-information project, not the official City of Plano website. Stable reference: corpuslaw.us/code/1f61d00d-b3bf-4b68-92bf-11421915456a
Sec. 6-254. - Deletions, additions, amendments.
The following deletions, additions, and amendments to the 2024 International Mechanical Code adopted in this division are hereby approved and adopted: Sec. 102.8.2; change to read as follows: Sec. 102.8.2 Provisions in referenced codes and standards. Where the extent of the reference to a referenced code or standard includes subject matter that is within the scope of this code, the provisions of this code, as applicable, shall take precedence over the provisions in the referenced code or standard. Any reference to NFPA 70 shall mean the National Electrical Code as adopted. Sec. 103.1; change to read as follows: Sec. 103.1 Creation of agency. The City of Plano Building Inspections Department is hereby created and the official in charge thereof shall be known as the code official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code. Sec. 112; delete the entire section and change to read as follows: SECTION 112 BUILDING STANDARDS COMMISSION. Sec. 112.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the code official relative to the application and interpretation of this code, there shall be and is hereby created a Building Standards Commission ("board"). The board shall be appointed by the Plano City Council and shall hold office at its pleasure. The board shall adopt rules of procedure for conducting its business and shall render all decisions in writing to the appellant with a duplicate copy to the code official. Sec. 114.2 Limitations of authority. An application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply, or an equivalent or better form of construction is proposed. The board shall not have the authority to waive requirements of this code or interpret the administration of this code. Sec. 114.3 Qualifications. The board shall consist of members who are qualified by experience and training and are not employees of the City of Plano. Sec. 114.4 Administration. The code official shall take immediate action in accordance with the decision of the board. Sec. 202; change to add a definition of Effective Dispersal Volume Charge as follows: Effective Dispersal Volume Charge (EDVC). The maximum refrigerant charge permitted for an effective dispersal volume. Section 202; change to add a definition of Refrigerant Detection System as follows: Refrigerant Detection System. The product safety standard addresses both refrigerant detection systems and leak detection systems. In the product safety standard, a leak detection system means "a sensing system which responds to refrigerant leaking from a refrigerating system." A leak detection system may include gas sensing, ultrasonic, or other such methods that meet the standards UL 60335-2-40/CSA C22.2 No. 60335-2-40 or UL 60335-2-89/CSA C22.2 No. 60335-2-89. [ASHRAE 15-2022: 3.1] Section 202; change to add a definition of Refrigerant Detector as follows: Refrigerant Detector. Refrigerant detector means a "Refrigerant sensor". A refrigerant sensor or detector means a sensing element combined with electronic circuitry that provides a digital output or an analog signal output that corresponds to the sensed refrigerant gas concentration. [ASHRAE 15-2022: 3.1] Section 306.3; change to read as follows: Sec. 306.3 Appliances in Attics. Attics containing appliances shall be provided with an opening and unobstructed passageway large enough to allow removal of the largest appliance. The passageway shall be not less than 30 inches (762 mm) high and 22 inches (559 mm) wide and not more than 20 feet (6096 mm) in length measured along the centerline of the passageway from the opening to the appliance. The passageway shall have continuous solid flooring not less than 24 inches (610 mm) wide. A level service space not less than 30 inches (762 mm) deep and 30 inches (762 mm) wide shall be present at the front or service side of the appliance. The clear access opening dimensions shall be a minimum of 20 inches by 30 inches (508 mm by 762 mm), and large enough to allow removal of the largest appliance. At a minimum, for access to the attic space, provide one of the following: 1. A permanent stair. 2. A pull-down stair with a minimum 300 lb. (136 kg) capacity. 3. An access door from an upper floor level. Exceptions: 1. The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening with the approval of the code official. 2. Where the passageway is unobstructed and not less than 6 feet (1829 mm) high and 22 inches (559 mm) wide for its entire length, the passageway shall be not greater than 50 feet (15,250 mm) in length. [Section 306.3.1 Electrical requirements to remain unchanged.] Section 306.5; change the first paragraph of Section 306.5 to read as follows: Sec. 306.5 Equipment and Appliances on Roofs or Elevated Structures. Where equipment requiring access or appliances are located on an elevated structure or the roof of a building such that personnel will have to climb higher than 16 feet (4877 mm) above grade to access such equipment or appliances, an interior or exterior means of access shall be provided. Exterior ladders providing roof access need not extend closer than 12 feet (2438 mm) to the finish grade or floor level below and shall extend to the equipment and appliances' level service space. Such access shall not require climbing over obstructions greater than 30 inches (762 mm) in height or walking on roofs having a slope greater than four units vertical in 12 units horizontal (33-percent slope). Such access shall not require the use of portable ladders. Where access involves climbing over parapet walls, the height shall be measured to the top of the parapet wall. Sec. 306.5.1; change to read as follows: Sec. 306.5.1 Sloped Roofs. Where appliances, equipment, fans or other components that require service are installed on a roof having a slope of three units vertical in 12 units horizontal (25-percent slope) or greater and having an edge more than 30 inches (762 mm) above grade at such edge, a catwalk at least 16 inches in width with substantial cleats spaced not more than 16 inches apart shall be provided from the roof access to a level platform at the appliance. The level platform shall be provided on each side of the appliance or equipment to which access is required for service, repair or maintenance. The platform shall be not less than 30 inches (762 mm) in any dimension and shall be provided with guards. The guards shall extend not less than 42 inches (1067 mm) above the platform, shall be constructed so as to prevent the passage of a 21-inch-diameter (533 mm) sphere and shall comply with the loading requirements for guards specified in the International Building Code. Access shall not require walking on roofs having a slope greater than four units vertical in 12 units horizontal (33-percent slope). Where access involves obstructions greater than 30 inches (762 mm) in height, such obstructions shall be provided with ladders installed in accordance with Section 306.5 or stairways installed in accordance with the requirements specified in the International Building Code in the path or travel to and from appliances, fans or equipment requiring service. Sec. 306; add Section 306.6 to read as follows: Sec. 306.6 Water Heaters above Ground or Floor. When the mezzanine or platform in which a water heater is installed is more than eight (8) feet (2438 mm) above the ground or floor level, it shall be made accessible by a stairway or permanent ladder fastened to the building. Exception: A maximum 10-gallon water heater (or larger with approval) is capable of being accessed through a lay-in ceiling and the water heater installed is not more than ten (10) feet (3048 mm) above the ground or floor level and may be reached with a portable ladder. Sec. 307.2.3 Auxiliary and secondary drain systems; amend item 2 in Section 307.2.3 to read as follows: 2. A separate overflow drain line shall be connected to the drain pan provided with the equipment. Such overflow drain shall discharge to a conspicuous point of disposal to alert occupants in the event of a stoppage of the primary drain. The overflow drain line shall connect to the drain pan at a higher level than the primary drain connection. The conspicuous point shall not create a hazard such as dripping over a walking surface or other areas so as to create a nuisance. Sec. 403.2.1 Recirculation of air; add an item 5 to Section 403.2.1 to read as follows: 5. Toilet rooms within private dwellings that contain only a water closet, lavatory, or combination thereof may be ventilated with an approved mechanical recirculating fan or similar device designed to remove odors from the air. Sec. 501.3 Exhaust discharge; add a fourth exception to Section 501.3 to read as follows: 4. Toilet room exhaust ducts may terminate in a warehouse or shop area when infiltration of outside air is present. Sec. 1104.2 Machinery room; change by adding an Exception 3 to read as follows: 3. Machinery Rooms are not required when in compliance with ASHRAE 15 Section 7.4. Sec. 1104.3.1; add Section 1104.3.1.1 to read as follows: Sec. 1104.3.1.1 Group A2L high-probability systems. High-probability systems using Group A2L refrigerants shall comply with ASHRAE 15 section 7.6. Sec. 1109.2.5 Refrigerant pipe shafts; change the exceptions to read as follows: Exceptions: 1. [Existing text to remain] 2. Piping in a direct refrigeration system where the refrigerant quantity does not exceed the limits of Table 1103.1 for the smallest occupied space through which the piping passes. 3. [Existing text to remain]
(Ord. No. 2016-3-9, § II, 3-14-16; Ord. No. 2018-11-12, § II, 11-26-18, eff. 1-2-19; Ord. No. 2022-1-13, § II, 1-24-22; Ord. No. 2025-6-8, § II, 6-9-25)
Ask a question about Plano law
Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.