For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6-275 — Amendments

Code of Ordinances, City of Plano, Texas (Supp. No. 153: codified through Ordinance No. 2025-10-2, adopted October 13, 2025) · Plano City Code § 6-275

Corpus is an independent public-information project, not the official City of Plano website. Stable reference: corpuslaw.us/code/42dbf6d0-457d-494d-a65a-01e49b65e275

Sec. 6-275. - Amendments.

The following amendments to the National Electrical Code adopted herein are hereby approved and adopted: Art. 110.2; change to read as follows: Art. 110.2 Approval. The conductors and equipment required or permitted by this Code shall be acceptable only if approved. Approval of equipment may be evident by listing and labeling of equipment by a Nationally Recognized Testing Lab (NRTL) with a certification mark of that laboratory or a qualified third party inspection agency or a field evaluation by a Field Evaluation Body accredited by either the International Code Council International Accreditation Service AC354 or ANSI National Accreditation Board programs and approved by the AHJ. Exception: Unlisted equipment that is relocated to another location within a jurisdiction or is field modified is subject to the approval by the AHJ. This approval may be by a field evaluation by a NRTL or qualified third-party inspection agency or a field evaluation by a Field Evaluation Body accredited by either the ICC IAS AC354 or ANAB programs and approved by the AHJ. Informational Note No. 1: See 90.7, Examination of Equipment for Safety, and 110.3, Examination, Identification, Installation, and Use of Equipment. See definitions of Approved, Identified, Labeled, and Listed. Informational Note No. 2: Manufacturer's self-certification of equipment may not necessarily comply with US product safety standards as certified by a Nationally Recognized Testing Lab (NRTL). Informational Note No. 3: National Fire Protection Association (NFPA) 790 and 791 provide an example of an approved method for qualifying a third-party inspection agency. Art. 110.12 (B); change to read as follows: (B) Integrity of Electrical Equipment and Connections. Internal parts of electrical equipment, including busbars, wiring terminals, insulators, and other surfaces, shall not be damaged or contaminated by foreign materials such as paint, plaster, cleaners, abrasives, corrosive residues or influences, fire, products of combustion, or water. There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment such as parts that are broken; bent; cut; or deteriorated by corrosion, chemical action, or overheating. Except where prohibited elsewhere in this Code, equipment shall be specifically evaluated by its manufacturer or a qualified testing laboratory prior to being returned to service. Art. 210.8 (A); change to read as follows: (A) Dwelling Units. All 125-volt through 250-volt receptacles installed in the following locations and supplied by single-phase branch circuits rated 150 volts or less to ground shall have ground-fault circuit-interrupter protection for personnel. (1) Bathrooms (2) Garages and also accessory buildings that have a floor located at or below grade-level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use (3) Outdoors (4) Crawl spaces - at or below grade-level (5) Basements (6) Kitchens (7) Areas with sinks and permanent provisions for food preparation, beverage preparation, or cooking (8) Sinks - where receptacles are installed within 1.8 m (6 ft) from the top inside edge of the bowl of the sink (9) Boathouses (10) Bathtubs or shower stalls - where receptacles are installed within 1.8 m (6 ft) of the outside edge of the bathtub or shower stall (11) Laundry areas (12) Indoor damp and wet locations Exception No. 1: Receptacles that are not readily accessible and are supplied by a branch circuit dedicated to electric snow-melting, deicing, or pipeline and vessel heating equipment shall be permitted to be installed in accordance with 426.28 or 427.22, as applicable. Exception No. 2: A receptacle supplying only a permanently installed premises security system shall be permitted to omit ground-fault circuit-interrupter protection. Exception No. 3: Listed weight-supporting ceiling receptacles (WSCR) utilized in combination with compatible weight-supporting attachment fittings (WSAF) installed for the purpose of supporting a ceiling luminaire or ceiling-suspended fan shall be permitted to omit ground-fault circuit-interrupter protection. If a general-purpose convenience receptacle is integral to the ceiling luminaire or ceiling-suspended fan, GFCI protection shall be provided. Exception No. 4: Factory-installed receptacles that are not readily accessible and are mounted internally to exhaust fan assemblies shall not require GFCI protection unless required by the installation instruction or listing. Informational Note: See 760.41(B) and 760.121(B) for power supply requirements for fire alarm systems. Art. 210.52 (C)(1); change to read as follows: (1) Wall Spaces. Receptacle outlets shall be installed so that no point along the wall line is more than 600 mm (24 in.) measured horizontally from a receptacle outlet in that space. The location of the receptacles shall be in accordance with 210.52(C)(3). Exception: Receptacle outlets shall not be required directly behind a range, counter mounted cooking unit, or sink in the installation described in Figure 210.52(C)(1). Art. 210.52 (C)(2); change to read as follows: (2) Island and Peninsular Countertops and Work Surfaces. Receptacle outlets, if installed to serve an island or peninsular countertop or work surface, shall be installed in accordance with 210.52(C)(3). If a receptacle outlet is not provided to serve an island or peninsular countertop or work surface, a Chapter 3 wiring method shall be installed and supplied from a small appliance branch circuit to a listed outlet box in the peninsular or island cabinet at an accessible location for future addition of a receptacle outlet to serve the island or peninsular countertop or work surface. Art. 210.63 (B); change to read as follows: (B) Other Electrical Equipment. In other than one- and two-family dwellings, a receptacle outlet shall be located as specified in 210.63(B)(1) and (B)(2). (1) Indoor Service Equipment. The required receptacle outlet shall be located within the same room or area as the service equipment. (2) Indoor Equipment Requiring Dedicated Equipment Spaces. Where equipment, other than service equipment, requires dedicated equipment space as specified in 110.26(E), the required receptacle outlet shall be located within the same room or area as the electrical equipment. Art. 220.6; add a new article to read as follows: Art. 220.6 Load Calculation. A load calculation shall be provided upon request when modifications to the electrical installation occur. Article 230.85 (C); change to read as follows: (C) Replacement. Where service equipment is replaced, all of the requirements of this section shall apply. Exception: Where a pre-existing installation is code compliant with 230.70 and only meter sockets, service entrance conductors, or related raceways and fittings are replaced, the requirements of this section shall not apply. Art. 250.50; change to read as follows: Art. 250.50 Grounding Electrode System. All grounding electrodes as described in 250.52(A)(1) through (A)(7) that are present at each building or structure served shall be bonded together to form the grounding electrode system. Where none of these grounding electrodes exist, one or more of the grounding electrodes specified in 250.52(A)(4) through (A)(8) shall be installed and used. Any building or structure supplied by a service or feeder with a foundation, footing or piers shall have either: (a) a concrete encased electrode, (b) a ground ring, 2/0 AWG grounding electrode conductor connecting two eight (8) foot driven ground rods spaced a minimum of twenty (20) feet apart connected by a 2/0 AWG bonding conductor buried in a trench at least 30 inches deep, or (c) chemical electrode installed. Exception: Concrete-encased electrodes of existing buildings or structures shall not be required to be part of the grounding electrode system where the steel reinforcing bars or rods are not accessible for use without disturbing the concrete. Art. 408.4; change to read as follows: Art. 408.4 Descriptions Required. (A) Circuit Directory or Circuit Description. Every circuit and circuit modification shall be provided with a legible and permanent description that complies with all the following conditions as applicable: (1) Located at each switch or circuit breaker in a switchboard or switchgear. (2) Included in a circuit directory that is located on the face of, inside of, or in an approved location adjacent and permanently affixed to the panel door in the case of a panelboard. (3) Clear, evident, and specific to the purpose or use of each circuit including spare positions with an unused overcurrent device. (4) Described with a degree of detail and clarity that is unlikely to result in confusion between circuits. (5) Not dependent on transient conditions of occupancy. (6) Clear in explaining abbreviations and symbols when used. (B) Source of Supply. All switchboards, switchgear, and panelboards supplied by a feeder(s) in other than one- or two-family dwellings shall be permanently marked in accordance with the following: (1) With the identification and physical location of where the power originates. (2) With a label that is permanently affixed and of sufficient durability to withstand the environment involved. (3) Using a method that is not handwritten. Art. 410.118; change to read as follows: Art. 410.118 Access to Other Boxes. Luminaires recessed in the ceilings, floors, or walls shall not be used to access outlet, pull, or junction boxes or conduit bodies, unless the box or conduit body is an integral part of the listed luminaire. Exception: Removable luminaires with a minimum measurement of 22 in. x 22 in. shall be permitted to be used as access to outlet, pull, junction boxes or conduit bodies. Art. 422.31 (B); change to read as follows: (B) Appliances Rated over 300 Volt-Amperes. For permanently connected appliances rated over 300 volt-amperes, the branch-circuit switch or circuit breaker shall be permitted to serve as the disconnecting means where the switch or circuit breaker is within sight from and is readily accessible to the appliance it serves or is capable of being locked in the open position in accordance with 110.25 and is readily accessible to the appliance it serves. Informational Note No. 1: For appliances employing unit switches, see 422.34. Informational Note No. 2: The following means of access are considered to constitute readily accessible for this code change when conforming to the additional access requirements of the I Codes: (1) A permanent stair. (2) A pull-down stair with a minimum 300 lb. (136 kg) capacity. (3) An access door from an upper floor level. Article 500.8 (A); change to read as follows: Art. 500.8 Equipment. Explosion-proof or dust-ignition-proof equipment shall not be permitted for use at temperatures lower than -25°C (-13°F) unless they are identified for low-temperature service. Articles 500 through 504 require equipment construction and installation that ensure safe performance under conditions of proper use and maintenance. Informational Note No. 1: It is important that inspection authorities and users exercise more than ordinary care with regard to installation and maintenance. Informational Note No. 2: Since there is no consistent relationship between explosion properties and ignition temperature, the two are independent requirements. Informational Note No. 3: Low ambient conditions require special consideration. Explosion proof or dust-ignition proof equipment may not be suitable for use at temperatures lower than -25°C (-13°F) unless they are identified for low-temperature service. However, at low ambient temperatures, flammable concentrations of vapors may not exist in a location classified as Class I, Division 1 at normal ambient temperature. (A) Suitability. Suitability of identified equipment shall be determined by one of the following: (1) Equipment listing or labeling; (2) Evidence of equipment evaluation from a qualified testing laboratory or inspection agency concerned with product evaluation; or (3) By special Permission Only. Evidence acceptable to the authority having jurisdiction such as a manufacturer's self-evaluation accompanied by an owner's engineering judgment. An engineering judgement must be signed and sealed under supervision of a qualified State of Texas licensed professional engineer engaged primarily in the design of maintenance of electrical installations as referenced by TBPELS 137.59(a)(b) as acceptable by the AHJ. Informational Note: Additional documentation for equipment may include certificates demonstrating compliance with applicable equipment standards, indicating special conditions of use, and other pertinent information. [Remainder of Article 500.8 is unchanged.] Informational Note No. 2 of Article 505.7; change to read as follows: Informational Note No. 2: Electrical equipment that is dependent on the protection technique permitted by 500.8(A) might not be suitable for use at temperatures lower than -20°C (-4°F) unless they are identified for use at lower temperatures. Low ambient conditions require special consideration. At low ambient temperatures, flammable concentrations of vapors might not exist in a location classified Class I, Zones 0, 1, or 2 at normal ambient temperature. Art. 505.7 (A); change to read as follows: (A) Implementation of Zone Classification System. Classification of areas, engineering and design, selection of equipment and wiring methods, installation, and inspection shall be performed under the supervision of a qualified State of Texas licensed professional engineer engaged primarily in the design or maintenance of electrical installations as referenced by TBPELS 137.59(a)(b) as acceptable by the AHJ. Art. 690.9 (D); change to read as follows: (D) Transformers. Overcurrent protection for power transformers shall be installed in accordance with 705.30(F). Art. 695.6 (A)(1); delete the exception and change to read as follows: (1) Services and On-Site Power Production Facilities. Service conductors and conductors supplied by on-site power production facilities shall be physically routed outside a building(s) and shall be installed as service-entrance conductors in accordance with 230.6, 230.9, and Parts III and IV of Article 230. Where supply conductors cannot be physically routed outside of buildings, the conductors shall be permitted to be routed through the building(s) where installed in accordance with 230.6(1) or (2). Art. 705.8 System Installation; change to read as follows: Art. 705.8 System Installation. Installation of one or more electrical power production sources operating in parallel with a primary source(s) of electricity shall be performed only by qualified persons. During the installation there shall be on site one of the following: (1) A person holding a Master Electrician License issued by the Texas Department of Licensing and Regulation. (2) A person holding a Journeyman Electrician License issued by the Texas Department of Licensing and Regulation. Art. 705.80 Power Source Capacity; change to read as follows: Art. 705.80 Power Source Capacity. For interconnected power production sources that operate in island mode, capacity shall be calculated using the sum of all power source output maximum currents for the connected power production source. Solar photovoltaic (PV) and wind systems shall not be included in the sum capacity. Art. 710.15 (A); delete the paragraph and information note in its entirety and change to read as follow: Art. 710.15(A). Reserved.

(Ord. No. 2014-11-15, § II, 11-24-14; Ord. No. 2018-11-13, § II, 11-26-18, eff. 1-2-19; Ord. No. 2022-1-14, § II, 1-24-22; Ord. No. 2025-6-13, § II, 6-9-25)

Ask a question about Plano law

Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.