Sec. 6-443. - Recirculation system.
(a) A recirculation system, consisting of pumps, piping, filters, and other accessory equipment shall be provided which will clarify the pool volume of water with a turnover rate not exceeding twelve (12) hours. (b) All piping shall be designed to reduce friction losses to a minimum and to carry the required quantity of water at a maximum velocity not to exceed ten (10) feet per second. Piping shall be of non-toxic material, resistant to corrosion, and able to withstand operating pressures. (c) The recirculation system shall include a strainer to prevent hair, lint, and etc. from reaching the pump and filters. Strainers shall be corrosion-resistant with openings not more than three-sixteenths ( 3/16 ) of an inch in size, providing a free flow area at least four (4) times the area of pump suction line and shall be readily accessible for frequent cleaning. (d) If vacuum cleaning is provided, it shall be an integral part of the recirculation system with sufficient connections located in the walls of the pool or surface skimmer. (e) Pumps and motors shall be of adequate capacity to provide the required number of turnovers of pool water as specified in subsection (a) of this section, and whenever possible shall be so located as to eliminate the need for priming. If the pump or suction piping is located above the overflow level of the pool, the pump shall be self-priming. The pump or pumps shall be capable of providing flow adequate for the backwashing of filters. (f) Heaters: Gas fired swimming pool heaters and swimming pool boilers must comply with all applicable American Standard Approval Requirements, including A.G.A. Oil burning equipment which must be approved by U.L. or other nationally recognized testing agency. All such equipment shall carry the corresponding seal for approval by the appropriate agencies.
(Ord. No. 2006-9-26, § II, 9-25-06)
Ask a question about Plano law
Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.