§ 6-564 — Backflow prevention methods and devices
Code of Ordinances, City of Plano, Texas (Supp. No. 153: codified through Ordinance No. 2025-10-2, adopted October 13, 2025) · Plano City Code § 6-564
Corpus is an independent public-information project, not the official City of Plano website. Stable reference: corpuslaw.us/code/23896a23-78fb-4466-9489-beee43d8df9a
Sec. 6-564. - Backflow prevention methods and devices.
(a) Any irrigation system that is connected to the potable water supply must be connected through a backflow prevention method approved by the Commission. The backflow prevention assembly must be approved by a laboratory that has equivalent capabilities for both the laboratory and field evaluation of backflow prevention assemblies and the University of Southern California Foundation for Cross-Connection Control and Hydraulic Research. The backflow prevention assembly must be installed in accordance with the laboratory approval standards. (b) If conditions that present a health hazard exist, one (1) of the following methods must be used to prevent backflow: (1) An air gap may be used if: (A) There is an unobstructed physical separation; and (B) The distance from the lowest point of the water supply outlet to the flood rim of the fixture or assembly into which the outlet discharges is at least one (1) inch or twice the diameter of the water supply outlet, whichever is greater. (2) Reduced pressure principle backflow prevention assemblies may be used if: (A) The assembly is installed with the termination point a minimum of twelve (12) inches above finished grade in a location that will ensure that the assembly will not become submerged; and (B) Drainage is provided for any water that may be discharged through the assembly relief valve. (3) Pressure vacuum breakers may be used if: (A) No back-pressure condition will occur; and (B) The device is installed at a minimum of twelve (12) inches above any downstream piping and the highest downstream opening. Pop-up sprinklers are measured from the retracted position from the top of the sprinkler. (4) Atmospheric vacuum breakers may be used if: (A) No back-pressure will be present; (B) There are no shutoff valves downstream from the atmospheric vacuum breaker; (C) The device is installed at a minimum of six (6) inches above any downstream piping and the highest downstream opening. Pop-up sprinklers are measured from the retracted position from the top of the sprinkler; (D) There is no continuous pressure on the supply side of the atmospheric vacuum breaker for more than twelve (12) hours in any 24-hour period; and (E) A separate atmospheric vacuum breaker is installed on the discharge side of each irrigation control valve, between the valve and all the emission devices that the valve controls. (c) Backflow prevention assemblies used in applications designated as health hazards must be tested upon installation and annually thereafter. (d) If there are no conditions that present a health hazard, double check valve backflow prevention assemblies may be used to prevent backflow if the device is tested upon installation and test cocks are used for testing only. (e) If a double check valve is installed below ground: (1) Test cocks must be plugged, except when the double check valve is being tested; (2) Test cock plugs must be threaded, water-tight, and made of non-ferrous material; (3) A y-type strainer is installed on the inlet side of the double check valve; (4) There must be a clearance between any fill material and the bottom of the double check valve to allow space for testing and repair; and (5) There must be space on the side of the double check valve to test and repair the double check valve. (f) If an existing irrigation system without a backflow-prevention assembly requires major maintenance, alteration, repair, or service, the system must be connected to the potable water supply through an approved, properly installed backflow prevention method before any major maintenance, alteration, repair, or service is performed. (g) The irrigator shall ensure the backflow prevention device is tested prior to being placed into service and the test results provided to the local water purveyor and the irrigation system's owner or owner's representative within ten (10) calendar days of testing of the backflow prevention assembly. (h) The city is not responsible for any pressure loss created by the installation of a backflow assembly.
(Ord. No. 2008-12-4, § I, 12-8-08; Ord. No. 2009-2-10, § I, 2-17-09)
Ask a question about Plano law
Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.
