Sec. 6-686. - Deletions, additions, amendments.
The following deletions, additions, and amendments to the International Energy Conservation Code adopted herein are hereby approved and adopted: Sec. C104.1; change section C104.1 by adding a new Section C104.1.2 to read as follows: Sec. C104.1.2 Alternative compliance. A building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance with the energy efficiency requirements of this section may, at the option of the code official, be considered in compliance. The United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. Sec. C403.7.4.1; change to read as follows: Sec. C403.7.4.1 Nontransient dwelling units. Nontransient dwelling units shall be provided with outdoor air energy recovery ventilation systems complying with not less than one of the following: 1. The system shall have an enthalpy recovery ratio of not less than 50 percent at cooling design condition and not less than 60 percent at heating design condition. 2. The system shall have a sensible recovery efficiency (SRE) that is not less than 65 percent at 32°F (0°C) and, in Climate Zones 0A, 1A, 2A and 3A, shall have a net moisture transfer (NMT) that is not less than 40 percent at 95°F (35°C). SRE and NMT shall be determined from a listed value or from interpolation of listed values at an airflow not less than the design airflow, based on testing in accordance with CAN/CSA C439. Exceptions: 1. Nontransient dwelling units in Climate Zone 3C. 2. Nontransient dwelling units with not more than 500 square feet (46 m 2 ) of conditioned floor area in Climate Zones 0, 1, 2, 3, 4C and 5C. 3. Enthalpy recovery ratio requirements at heating design condition in Climate Zones 0, 1 and 2. 4. Enthalpy recovery ratio requirements at cooling design condition in Climate Zones 4, 5, 6, 7 and 8. 5. Dwelling units using ventilation systems per the Fan Efficacy Table in R406, shall be considered in compliance. Sec. C405.2.10; delete Section C405.2.10 "Sleeping unit and dwelling unit lighting and switched receptacle controls" in its entirety. Sec. R104; change Section R104.1 by adding a new Section R104.1.2 (N1101.4.1) to read as follows: Sec. R104.1.2 (N1101.4.1) Alternative compliance. A building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance with the energy efficiency requirements of this section may, at the option of the code official, be considered in compliance. The United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. Regardless of the program or the path to compliance, each one- and two-family dwelling shall be tested for air and duct leakage as prescribed in Section R402.4.1.2 (N1102.4.1.2) and R403.3.3 (N1103.3.3), respectively. Sec. R105.2.2; delete Section R105.2.2 "Solar-ready system" in its entirety. Sec. R106.3; delete Section R106.3 "Permit valuation" in its entirety. Sec. R202 (N1101.6); change Section R202 by adding the following definition: DYNAMIC GLAZING. Any fenestration product that has the fully reversible ability to change its performance properties, including U-factor, solar heat gain coefficient (SHGC), or visible transmittance (VT). Sec. R401.2.1; change to read as follows: Sec. R401.2.1 Prescriptive Compliance Option. The Prescriptive Compliance Option requires compliance with Sections R401 through R404. Table R402.1.2; change a portion of Table R402.1.2 "Maximum Assembly U-Factors and Fenestration Requirements" to add an additional category and subnote "f" to read as follows (remainder of Table is unchanged): Climate Zone | 3 Attic roofline U-factor f | 0.035 f. Air-impermeable insultation located at the attic roofline but below the roof deck may be used if mechanical equipment and air distribution system are located entirely within the building thermal envelope. "Air-impermeable shall be defined as having an air permeance not exceeding 0.2 L/s- m 2 at 75 Pa Pressure differential tested according to ASTM E 2178 or ASTM E 283. Table R402.1.3; change a portion of Table R402.1.3 "Insulation Minimum R-Values and Fenestration Requirements by Component" to add an additional category and subnote "i" to read as follows (remainder of Table is unchanged): Climate Zone | 3 Attic roofline R-value i | 30+0 ci i. Air-impermeable insulation of R-30&0 or greater located at the attic roofline but below the roof deck may be used if mechanical equipment and air distribution system are located entirely within the building thermal envelope. "Air-impermeable" shall be defined as having an air permeance not exceeding 0.02 L/s-m 2 at 75 Pa pressure differential tested according to ASTM E 2178 or ASTM E 283. Sec. R402.2.10 (N1102.2.10); change to read as follows: Sec. R402.2.10 (N1102.2.10) Slab-on-grade floors. Slab-on-grade floors with a floor surface within 24 inches (610 mm) above or below grade shall be insulated in accordance with Section R402.2.10.1 or R402.2.10.2. Exception: Slab-edge insulation is not required in jurisdictions designated by the code official as having a moderate to heavy or very heavy termite infestation probability. Sec. R402.5.5 (N1102.5.5); change to read as follows: Sec. R402.5.5 (N1102.5.5) Air-sealed electrical and communication outlet boxes. Air-sealed electrical and communication outlet boxes that penetrated the air barrier of the building thermal envelope shall be caulked, taped, gasketed or otherwise sealed to the air barrier element being penetrated. Air-sealed boxes shall be buried in or surrounded by insulation. Air-sealed boxes shall be tested and marked in accordance with NEMA OS 4. Air-sealed boxes shall be installed in accordance with the manufacturer's instructions. Exception: Boxes may be air-sealed in the field using caulk, tape, gasket or other approved method to prevent air leakage through the box in lieu of NEMA OS 4 boxes. Boxes air-sealed in the field shall be sealed to the air barrier element being penetrated and installed in accordance with manufacturer's instructions. Sec. R404.2; delete Section R404.2 "Interior lighting controls" in its entirety. Table R405.4.2(1) (N1105.4.2(1)); change Table R405.4.2(1) "Specifications for the Standard Reference and Proposed Designs" by amending the Foundations building component and adding a subnote "n" to read as follows (remainder of Table is unchanged): BUILDING COMPONENT | STANDARD REFERENCE DESIGN | PROPOSED DESIGN Foundations | Type: same as proposed. | As proposed Foundation wall or slab extension above grade: 1 foot (30 cm). Foundation wall or slab extension below grade: same as proposed Foundation wall or slab perimeter length: same as proposed. Soil characteristics: same as proposed. | As proposed Foundation wall U-factor and slab-on-grade F-factor: as specified in Table R402.1.2. n | As proposed For SI: 1 square foot = 0.93 m 2 , 1 British thermal unit = 1055 J, 1 pound per square foot = 4.88 kg/m 2 , 1 gallon (US) = 3.785 L, °C = (°F-32)/1.8, 1 degree = 0.79 rad. n. In accordance with Section R402.2.10, a maximum F-factor of 0.73 shall apply for the reference design in jurisdictions designated by the code official as having a moderate to heavy or very heavy termite infestation probability. Table R406.5 (N1106.5); change a portion of Table R406.5 "Maximum Energy Rating Index" to read as follows (remainder of Table is unchanged): TABLE R406.51 MAXIMUM ENERGY RATING INDEX CLIMATE ZONE | ENERGY RATING INDEX Not including OPP | ENERGY RATING INDEX with OPP 3 | 59 1 This table is effective from September 1, 2022 until August 31, 2025. TABLE R406.52 MAXIMUM ENERGY RATING INDEX CLIMATE ZONE | ENERGY RATING INDEX Not including OPP | ENERGY RATING INDEX with OPP 3 | 57 2 The table is effective from September 1, 2025 to August 31, 2028. TABLE R406.5 (N1106.5) 3 MAXIMUM ENERGY RATING INDEX CLIMATE ZONE | ENERGY RATING INDEX Not including OPP | ENERGY RATING INDEX WITH OPP 3 | 55 3 This table is effective on or after September 1, 2028. Section R408; Section R408 "Additional Efficiency Requirements" is deleted in its entirety.
(Ord. No. 2016-3-7, § II, 3-14-16; Ord. No. 2018-11-14, § II, 11-26-18, eff. 1-2-19; Ord. No. 2022-1-15, § II, 1-24-22; Ord. No. 2025-6-10, § II, 6-9-25)
Ask a question about Plano law
Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.