§ 6-710 — Deletions, additions, amendments
Code of Ordinances, City of Plano, Texas (Supp. No. 153: codified through Ordinance No. 2025-10-2, adopted October 13, 2025) · Plano City Code § 6-710
Corpus is an independent public-information project, not the official City of Plano website. Stable reference: corpuslaw.us/code/f4c42cff-4290-4295-8477-b00620340c13
Section 6-710. - Deletions, additions, amendments.
The following deletions, additions, and amendments to the International Residential Code adopted herein are hereby approved and adopted: Sec. R101.1; change the section to read as follows: Sec. R101.1 Title. These regulations shall be known as the Residential Code for One- and Two-family Dwellings of the City of Plano, Texas hereinafter referred to as "this code." Sec. R102.4; change the section to read as follows: Sec. R102.4 Referenced codes and standards. The codes, when specifically adopted, and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections R102.4.1 and R102.4.2. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference made to NFPA 70 or the Electrical Code shall mean the Electrical Code as adopted. Secs. R103 and R103.1; change the section to read as follows [Sections R103.2 and R103.3 to remain unchanged]: SECTION R103 — BUILDING INSPECTIONS DEPARTMENT. Sec. R103.1 Creation of enforcement agency. The Building Inspections Department is hereby created and the official in charge thereof shall be known as the building official. Sec. R104.2.3.1 Flood hazard areas; this section is deleted in its entirety. Sec. R104.3.1 Determination of substantially improved or substantially damaged existing buildings in flood hazard areas; this section is deleted in its entirety. Sec. R104.7; change the section to read as follows: Sec. R104.7 Official records. The building official shall keep official records as required in Sections R104.7.1 through R104.7.5. Such official records shall be retained for as long as the building or structure to which such records relate remains in existence, unless otherwise provided by other regulations. Sec. R105.2; change the Building category of Section R105.2 "Work exempt from permit" to read as follows (all other provisions and text of Section 105.2 to remain unchanged): Building: 1. One-story detached accessory structures, provided that the floor area does not exceed 120 square feet. 2. [Deleted.] 3. Retaining walls that are not over 4 feet (1219 mm) in height measured from the bottom of the footing to the top of the wall, unless supporting a surcharge. 4. Water tanks supported directly upon grade if the capacity does not exceed 5,000 gallons (18 927 L) and the ratio of height to diameter or width does not exceed 2 to 1. 5. [Deleted.] 6. Painting, papering, tiling, carpeting, cabinets, counter tops and similar finish work. 7. Prefabricated swimming pools that are less than 24 inches (610 mm) deep. 8. Swings and other playground equipment. 9. Window awnings supported by an exterior wall that do not project more than 54 inches (1372 mm) from the exterior wall and do not require additional support. 10. Decks not exceeding 200 square feet (18.58 m 2 ) in area, that are not more than 30 inches (762 mm) above grade at any point, are not attached to a dwelling or townhouse and do not serve the exit door required by Section R311.4. Sec. R105.3; change the section to read as follows: Sec. R105.3 Application for permit. A. To obtain a permit, the applicant shall first file an application therefor in writing on a form furnished by the department of building safety for that purpose. Such application shall: 1. Identify and describe the work to be covered by the permit for which application is made. 2. Describe the land on which the proposed work is to be done by legal description, street address or similar description that will readily identify and definitely locate the proposed building or work. 3. Indicate the use and occupancy for which the proposed work is intended. 4. Be accompanied by construction documents and other information as required in Section R106.1. 5. [Deleted.] 6. Be signed by the applicant or the applicant's authorized agent. 7. Give such other data and information as required by the building official. B. To obtain a permit, the applicant shall be registered as a contractor. Such registration requirements are as follows: 1. Contractors shall register by making application on forms provided by the building official. 2. Electrical, irrigation, mechanical, and plumbing contractors shall provide proof of required State of Texas licenses and insurance. 3. A contractor's registration may be suspended for the following causes: a. The contractor fails to finalize permits by obtaining the required, approved inspections. b. The contractor allows use or occupancy of a structure for which a permit was obtained without first obtaining the required authorization. c. Expiration, suspension or revocation of required license, bond, or insurance. Exception: Homeowners may obtain permits to do work at their residence without being registered. Section R105.3.1; change the section to read as follows: Sec. R105.3.1 Action on application. The building official shall examine or cause to be examined applications for permits and amendments thereto within a reasonable time after filing. If the application or the construction documents do not conform to the requirements of pertinent laws, the building official shall reject such application in writing stating the reasons thereof. If the building official is satisfied that the proposed work conforms to the requirements of this code and laws and ordinances applicable thereto, the building official shall issue a permit therefor as soon as practicable. A demolition permit may be withheld for any building or structure within the Plano Historic Building and Site Survey, as designated in the Preservation Plan, for a period not exceeding thirty (30) days pending review by the Heritage Commission. Section R105.10; change Section R105 by adding a new Section R105.10 to read as follows: Sec. R105.10 Withdrawn permits. Permits may be withdrawn by the applicant if no work has commenced on the project. Permit fees exceeding $100.00 may be partially refunded. Where applicable, fees will be refunded at 80 percent of their original value, excluding the plan review and fire protection plan review deposits. Permits for which work has commenced may not be withdrawn unless a subsequent permittee has obtained a permit to complete the work, or when work has started unless an inspection has been made and the building official has determined that the existing work has created no violation of any code or ordinance. Expired permits may be withdrawn if determined by the building official that no work has commenced. Withdrawn permits with fees of less than one hundred dollars ($100) are nonrefundable. Sec. R106.1.3; change the section to read as follows: Sec. R106.1.3 Information on braced wall design. For buildings and structures utilizing braced wall design, and where required by the building official, braced wall lines shall be identified on the construction documents and shall be designed by an engineer licensed by the State of Texas. Pertinent information including, but not limited to, bracing methods, location and length of braced wall panels and foundation requirements of braced wall panels at top and bottom shall be provided. Sec. R106.3.1; change the section to read as follows: Sec. R106.3.1 Approval of construction documents. When the building official issues a permit, the construction documents shall be approved, in writing, or by a stamp which states "APPROVED and APPROVED AS NOTED BY THE BUILDING OFFICIAL." One set of construction documents so reviewed shall be retained by the building official. The other set shall be returned to the applicant, shall be kept at the site of work, and shall be open to inspection by the building official or a duly authorized representative. Sec. R107; change Section R107 by adding a new Section R107.2.1 to read as follows: Sec. R107.2.1 Adequate toilet facilities. In partially completed phased subdivisions or projects, more than one permanent or temporary toilet may be required, but not less than one shall be provided and at least one permanent or temporary toilet facility shall be maintained in each subdivision or project for the employees or subcontractors of each builder holding a permit for a building in that subdivision or project. A toilet facility must be provided by each builder as long as the builder holds an active building permit in the subdivision or project. For purposes of this section, permanent toilet facility is defined as a room in an existing building or in the building being constructed with a water closet installed in such a room that conforms to the Plumbing Code and is continuously available to all workers involved in a construction project. Temporary toilet facility is defined as a portable, fully enclosed, chemically sanitized toilet, which is serviced and cleaned at least once each week. A Stop Work Order may be issued for any project not in compliance with this section. Sec. R108; change Section R108 by adding a new Section 108.7 to read as follows: Sec. R108.7 Re-inspection fee. A re-inspection fee may be charged due to one of the following occurrences: 1. The inspection called for is not ready when the inspector arrives. 2. No building address or permit card is clearly posted. 3. Approved plans are not on the job site available to the inspector. 4. The building is locked or work otherwise not available for inspection when called. 5. The job site is red-tagged twice for the same item. 6. Violations exist on the property including failure to maintain erosion control, trash control or tree protection. Sec. R109.1.5; change Section R109.1.5 to add a new Section 109.1.5.2 and Figure R109.1.5.2 to read as follows: Sec. R109.1.5.2 Fences with rolling gates. Where a fence with a rolling gate is constructed, a trash dumpster service access pad shall be installed. The trash dumpster service access pad shall be a ten foot by four foot (10x4) space, setback four (4) feet from the edge of the alley, or shall be two (2) five foot by four foot (5x4) spaces, setback four (4) feet from the edge of the alley. See Figure 109.1.5.2. [image omitted; see the official code] Section R110.1; change the section to read as follows: Sec. R110.1 Use and change of occupancy. A building or structure shall not be used or occupied in whole or in part, and a change of occupancy of a building or structure or portion thereof shall not be made, until the building official has issued an approval thereof as provided herein. Issuance of an approval shall not be construed as approval of a violation of the provisions of this code or any other ordinance of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid. Exceptions: 1. Certificates of occupancy are not required for work exempt from permits under Section R105.2. 2. Accessory buildings or structures. Sec. R110.2 Certificate issued; delete section in its entirety. Sec. R110.3; change section to read as follows: Sec. R110.3 Temporary occupancy. The building official is authorized to issue a temporary approval before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. The building official shall set a time period during which the temporary approval is valid. Sec. R110.4; change section to read as follows: Sec. R110.4 Revocation. The building official is authorized to suspend or revoke an approval issued under the provisions of this code, in writing, whenever the occupancy approval is issued in error, or on the basis of incorrect information supplied, or where it is determined that the building or structure or portion thereof is in violation of the provisions of this code or other ordinance of the jurisdiction. Sec. R112; change the title of the section to read as follows: SECTION R112 BUILDING STANDARDS COMMISSION. Sec. R114; change Section R114 by adding a new Section R114.5 to read as follows: Sec. R114.5 Construction debris. 1. Whenever work is being done that is authorized by a permit, and construction debris from that work is not confined to a container or to a site on the property approved by the building official or his designee, and such construction debris poses a threat to public health, safety, and comfort so that it constitutes a nuisance, the building official or his designee may order the work stopped and the contractor shall clean up the construction debris within thirty-six (36) hours of receiving notice of the violation. After the expiration of the thirty-six (36) hour period, contractor shall pay the city a re-inspection fee to off-set costs incurred by the city due to the necessary re-inspection before the stop work order is lifted. 2. As used herein, the term "construction debris" shall include all materials utilized in the construction process, including all litter and debris deposited and left remaining upon the premises of a job site by a contractor, subcontractor, and their employees, agents, and assigns. 3. As used herein "costs" shall mean all expense incurred by the city for the cleaning of the job site and the amount of any unpaid municipal court fine. Sec. R202; change the definition of "Townhouse Unit" in Section R202 "Definitions" to read as follows: TOWNHOUSE UNIT. A single-family dwelling unit separated by property lines in a townhouse that extends from foundation to roof and that has a yard or public way on at least two sides. Sec. R202; add definitions of "Floor Area, Gross" and "Recreation Room" to Section R202 "Definitions" to read as follows: FLOOR AREA, GROSS. The floor area within the inside perimeter of the exterior walls of the building under consideration, exclusive of vent shafts and courts, without deduction for corridors, stairways, closets, the thickness of interior walls, columns, or other features. The floor area of a building, or portion thereof, not provided with surrounding exterior walls shall be usable area under the horizontal projection of the roof or floor above. The gross floor area shall not include shafts with no openings or interior courts. RECREATION ROOM. A room in a dwelling unit, which is intended for such uses as viewing television or films, listening to recordings, or participating in video or similar games. The area of this room is not to exceed one-tenth of the floor area of the habitable space of the dwelling unit. Table R301.2 (1); change Table R-301.2 to read as follows: TABLE R-301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA [image omitted; see the official code] Sec. R302.1; change Section R302.1 "Exterior walls" by adding an Exception 6 to read as follows: 6. Open non-combustible carport structures may be constructed when also approved within adopted ordinances. Sec. R302.2.6; change Section R302.2.6 "Structural independence" by deleting Exception 6 (remainder of section and exceptions unchanged). Sec. R302.5.1; change section to read as follows: Sec. R302.5.1 Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and dwelling unit shall be equipped with solid wood doors not less than 1⅜ inches (35 mm) in thickness, solid or honeycomb-core steel doors not less than 1⅜ inches (35 mm) thick, or 20-minute fire-rated doors. Sec. R306 Flood Resistant Construction; delete the section in its entirety. Sec. R308.1; change section to read as follows: Sec. R308.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property, and from rear alleyways adjacent to the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Sec. R309; delete Sections R309.2 "One- and two-family dwellings automatic sprinkler systems" and R309.2.1 "Design and installation" in their entirety. Sec. R316 Habitable Attics; delete the section in its entirety. Sec. R325.2; amend the exception in Section R325.2 "Bathrooms" to read as follows: Exception: The glazed areas shall not be required where artificial light and a local exhaust system are provided. The minimum local exhaust rates shall be determined in accordance with Section M1505. Exhaust air from the space shall be exhausted directly to the outdoors. Spaces containing only a water closet, or water closet and a lavatory, may be ventilated with an approved mechanical recirculating fan or similar device designed to remove odors from the air. Sec. R327; change by adding new Section R327.3 and new Figure 327.3 to read as follows: Sec. R327.3 Blocking locations. Required at one toilet at grade level with blocking installed at rear wall and one wall adjacent to toilet and at one tub or shower at grade level. Blocking as shown in Figure R327.3. [image omitted; see the official code] Figure R327.3 Sec. R327; change by adding new Section R327.4 and new Figure 327.4 to read as follows: Sec. R327.4 Wall blocking. Blocking may be ½" plywood or 2 × solid wood blocking, or equivalent, flush with wall as shown in Figure R327.4. Figure R327.4 [image omitted; see the official code] Sec. 328; change Section R328 "Swimming Pools, Spas and Hot Tubs" by adding a new Section 328.1.1 to read as follows: Sec. 328.1.1 Adjacency to Structural Foundation. Depth of the swimming pool and spa shall maintain a ratio of 1:1 from the nearest building foundation or footing of a retaining wall. Exception: A sealed engineered design drawing of the proposed new structure shall be submitted for approval. Sec. R401.2, change section to read as follows: Sec. R401.2. Requirements. Foundation construction shall be capable of accommodating all loads in accordance with Section R301 and of transmitting the resulting loads to the supporting soil. Fill soils that support footings and foundations shall be designed, installed and tested in accordance with accepted engineering practice. Every foundation and/or footing, or any size addition to an existing post-tension foundation, regulated by this code shall be designed and sealed by a Texas-registered engineer. Sec. R602.6; change section to read as follows. Sec. R602.6.1; change section to read as follows: Sec. R602.6.1 Drilling and notching of top plate. When piping or ductwork is placed in or partly in an exterior wall or interior load-bearing wall, necessitating cutting, drilling or notching of the top plate by more than 50 percent of its width, a galvanized metal tie not less than 0.054-inch-thick (1.37 mm) (16 Ga) and 5 inches (127 mm) wide shall be fastened across and to the plate at each side of the opening with not less than eight 10d (0.148 inch diameter) having a minimum length of 1½ inches (38 mm) at each side or equivalent. Fasteners will be offset to prevent splitting of the top plate material. The metal tie must extend a minimum of 6 inches past the opening. See figure R602.6.1. Exception: Where the entire side of the wall with the notch or cut is covered by wood structural panel sheathing. Figure R602.6.1; delete the figure and insert the following figure: [image omitted; see the official code] Table R603.7(2); change Table R603.7(2) "Header to King Stud Connection Requirements" by amending the footnotes to read as follows: a. All screw sizes shown are minimum size, not to exceed 2 sizes larger. b. Deleted. c. Deleted. d. Minimum Grade 33 ksi steel shall be used for 33 mil and 43 mil thicknesses. Minimum Grade 50 ksi steel shall be used for 54 and 68 mil thicknesses. Sec. R703; change Section R703 "Exterior Wall Covering" by adding a new Section R703.8.4.1.2 "Veneer Ties for Wall Studs" to read as follows: Sec. R703.8.4.1.2 Veneer Ties for Wall Studs. In stud framed exterior walls, all ties may be anchored to studs as follows: 1. When studs are 16 in (407 mm) o.c., stud ties shall be spaced no further apart than 24 in (737 mm) vertically starting approximately 12 in (381 mm) from the foundation; or 2. When studs are 24 in (610 mm) o.c., stud ties shall be spaced no further apart than 16 in (483 mm) vertically starting approximately 8 in (254 mm) from the foundation. Section R902.1 Roof assemblies; change Section R902.1 by adding a new exception to read as follows: 5. Non-classified roof coverings shall be permitted on one-story detached accessory structures used as tool and storage sheds, playhouses, and similar uses, provided the floor area does not exceed 120 square feet. Sec. R1005.9 Factory-built chimney offsets; delete this section in its entirety. Chapter 11 [RE]; delete the chapter in its entirety and insert the following: CHAPTER 11 [RE]. Refer to the 2024 International Energy and Conservation Code for energy code provisions and recommended amendments. Sec. M1305.1.2; change section to read as follows: Sec. M1305.1.2 Appliances in attics. Attics containing appliances shall be provided with an opening and a clear and unobstructed passageway large enough to allow removal of the largest appliance, but not less than 30 inches (762 mm) high and 22 inches (559 mm) wide and not more than 20 feet (6096 mm) long measured along the centerline of the passageway from the opening to the appliance. The passageway shall have continuous solid flooring in accordance with Chapter 5 not less than 24 inches (610 mm) wide. A level service space not less than 30 inches (762 mm) deep and 30 inches (762 mm) wide shall be present along all sides of the appliance where access is required. The clear access opening dimensions shall be not less than 20 inches by 30 inches (508 mm by 762 mm), and large enough to allow removal of the largest appliance. At a minimum, for access to the attic space, provide one of the following: 1. A permanent stair. 2. A pull-down stair with a minimum 300 lb. (136 kg) capacity. 3. An access door from an upper floor level. Exceptions: 1. The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening with the approval of the code official. 2. Where the passageway is unobstructed and not less than 6 feet (1829 mm) high and 22 inches (559 mm) wide for its entire length, the passageway shall be not greater than 50 feet (15,250 mm) in length. [Section M1305.1.2.1 Electrical requirements to remain unchanged.] Section M1411.3; change section to read as follows: Sec. M1411.3 Condensate disposal. Condensate from all cooling coils or evaporators shall be conveyed from the drain pan outlet to a sanitary sewer through a trap, by means of a direct or indirect drain. Such piping shall maintain a minimum horizontal slope in the direction of discharge of not less than ⅛-unit vertical in 12 units horizontal (1-percent slope). Condensate shall not discharge into a street, alley or other area where it would cause a nuisance. Sec. M1411.3.1; change section by revising the text of Items 3 and 4 to read as follows: 3. An auxiliary drain pan without a separate drain line shall be installed under the coils on which condensation will occur. This pan shall be equipped with a water level detection device conforming to UL 508 that will shut off the equipment served prior to overflow of the pan. The pan shall be equipped with a fitting to allow for drainage. The auxiliary drain pan shall be constructed in accordance with Item 1 of this section. A water level detection device may be installed only with prior approval of the building official. 4. A water level detection device conforming to UL 508 shall be installed that will shut off the equipment served in the event that the primary drain is blocked. The device shall be installed in the primary drain line, the overflow drain line or the equipment-supplied drain pan, located at a point higher than the primary drain line connection and below the overflow rim of such pan. A water level detection device may be installed only with prior approval of the building official. Sec. M1401 General; change section by adding a new Section M1401.1.1 "Air conditioning equipment" to read as follows: Sec. M1401.1.1 Air conditioning equipment. All residential dwelling units shall be installed with and air conditioning system with the ability to condition and maintain conditioned air 20 degrees below the ambient outside air temperature in all habitable spaces. Sec. M1411.9; change section to read as follows: Sec. M1411.9 Condensate disposal. Condensate from all cooling coils or evaporators shall be conveyed from the drain pan outlet to an approved place of disposal to a sanitary sewer through a trap, by means of a direct or indirect drain. Such piping shall maintain a minimum horizontal slope in the direction of discharge of not less than ⅛-unit vertical in 12cunits horizontal (1-percent slope). Condensate shall not discharge into a street, alley, or other area where it would cause a nuisance. Sec. M1411.9.1; change Section M1411.9.1 "Auxiliary and secondary drain systems" by amending Items 3 and 4 to read as follows: 3. An auxiliary drain pan without a separate drain line shall be installed under the coils on which condensation will occur. This pan shall be equipped with a water level detection device conforming to UL 508 that will shut off the equipment served prior to overflow of the pan. The pan shall be equipped with a fitting to allow for drainage. The auxiliary drain pan shall be constructed in accordance with Item 1 of this section. A water level detection device may be installed only with prior approval of the building official. 4. A water level detection device conforming to UL 508 shall be installed that will shut off the equipment served in the event that the primary drain is blocked. The device shall be installed in the primary drain line, the overflow drain line or the equipment-supplied drain pan, located at a point higher than the primary drain line connection and below the overflow rim of such pan. A water level detection device may be installed only with prior approval of the building official. Sec. M1411.9.1.1; change section to read as follows: Sec. M1411.9.1.1 Water-level monitoring devices. On down-flow units and other coils that do not have secondary drain or provisions to install a secondary or auxiliary drain pan, a water-level monitoring device shall be installed inside the primary drain pan. This device shall shut off the equipment served in the event that the primary drain becomes restricted. Devices shall not be installed in the drain line. A water level detection device may be installed only with prior approval of the building official. Sec. M1503.6; change section and exception to read as follows (Sections M1503.6.1 and M1503.6.2 remain unchanged): Sec. M1503.6 Makeup air required. Where one or more gas, liquid or solid fuel-burning appliance that is neither direct-vent nor uses a mechanical draft venting system is located within a dwelling unit's air barrier, each exhaust system capable of exhausting in excess of 400 cubic feet per minute (0.19 m 3 /s) shall be mechanically or passively provided with makeup air at a rate approximate to the difference between exhaust air rate and 400 cubic feet per minute. Such makeup air systems shall be equipped with not fewer than one damper complying with Section M1503.6.2. Exception: Makeup air is not required for exhaust systems installed for the exclusive purpose of space cooling and intended to be operated only when windows or other air inlets are open. Where all appliances in the house are of sealed combustion, power-vent, unvented, or electric, the exhaust hood system shall be permitted to exhaust up to 600 cubic feet per minute (0.28 m 3 /s) without providing makeup air. Exhaust hood systems capable of exhausting in excess of 600 cubic feet per minute (0.28 m 3 /s) shall be provided with a makeup air at a rate approximately to the difference between the exhaust air rate and 600 cubic feet per minute. Sec. M2005.2; change section to read as follows: Sec. M2005.2 Prohibited locations. Fuel-fired water heaters shall not be installed in a room used as a storage closet. Water heaters located in a bedroom or bathroom shall be installed in a sealed enclosure so that combustion air will not be taken from the living space. Access to such enclosure may be from the bedroom or bathroom when through a solid door, weather-stripped in accordance with the exterior door air leakage requirements of the International Energy Conservation Code and equipped with an approved self-closing device. Installation of direct-vent water heaters within an enclosure is not required. Sec. G2408.3 (305.5) Private garages; delete section in its entirety. Sec. G2415.2 (404.2); change section to read as follows: Sec. G2415.2 (404.2) CSST. CSST piping systems shall be installed in accordance with the terms of their approval, the conditions of listing, the manufacturer's instructions and this code. Both ends of each section of medium pressure gas piping shall identify its operating gas pressure with an approved tag. The tags are to be composed of aluminum or stainless steel and the following wording shall be stamped into the tag: "WARNING: ½ to 5 psi gas pressure - Do Not Remove" Sec. G2415.12 (404.12); change section to read as follows: Sec. G2415.12 (404.12) Minimum burial depth. Underground piping systems shall be installed a minimum depth of 18 inches (457 mm) below grade. Secc. G2415.12.1 (404.12.1) Individual outdoor appliances; section deleted in its entirety. Sec. G2417.1 (406.1); change section to read as follows: Sec. G2417.1 (406.1) General. Prior to acceptance and initial operation, all piping installations shall be inspected and pressure tested to determine that the materials, design, fabrication, and installation practices comply with the requirements of this code. The permit holder shall make the applicable tests prescribed in Sections 2417.1.1 through 2417.1.5 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the building official when the piping system is ready for testing. The equipment, material, power and labor necessary for the inspections and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. Sec. G2417.4; change section to read as follows: Sec. G2417.4 (406.4) Test pressure measurement. Test pressure shall be measured with a monometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Sec. G2417.4.1; change section to read as follows: Sec. G2417.4.1 (406.4.1) Test pressure. The test pressure to be used shall be no less than 3 psig (20 kPa gauge), or at the discretion of the code official, the piping and valves may be tested at a pressure of at least six (6) inches (152 mm) of mercury, measured with a manometer or slope gauge. For tests requiring a pressure of 3 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one-half inches (3½"), a set hand, 1/10 pound incrementation and pressure range not to exceed 6 psi for tests requiring a pressure of 3 psig. For tests requiring a pressure of 10 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one-half inches (3½"), a set hand, a minimum of 2/10 pound incrementation and a pressure range not to exceed 20 psi. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa) (1/2 psi) and less than 200 inches of water column pressure (52.2 kPa) (7.5 psi), the test pressure shall not be less than ten (10) pounds per square inch (69.6 kPa). For piping carrying gas at a pressure that exceeds 200 inches of water column (52.2 kPa) (7.5 psi), the test pressure shall be not less than one and one-half times the proposed maximum working pressure. Diaphragm gauges used for testing must display a current calibration and be in good working condition. The appropriate test must be applied to the diaphragm gauge used for testing. Sec. G2417.4.2; change section to read as follows: Sec. G2417.4.2 (406.4.2) Test duration. The test duration shall be held for a length of time satisfactory to the building official, but in no case for less than fifteen (15) minutes. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa), the test duration shall be held for a length of time satisfactory to the building official, but in no case for less than thirty (30) minutes. Sec. G2420.1 (406.1); change section by adding a new Section G2420.1.4 to read as follows: Sec. G2420.1.4 Valves in CSST installations. Shutoff valves installed with corrugated stainless steel (CSST) piping systems shall be supported with an approved termination fitting, or equivalent support, suitable for the size of the valves, of adequate strength and quality, and located at intervals so as to prevent or damp out excessive vibration but in no case greater than 12-inches from the center of the valve. Supports shall be installed so as not to interfere with the free expansion and contraction of the system's piping, fittings, and valves between anchors. All valves and supports shall be designed and installed so they will not be disengaged by movement of the supporting piping. Sec. G2420.5.1 (409.5.1); change section to read as follows: Sec. G2420.5.1 (409.5.1) Located within the same room. The shutoff valve shall be located in the same room as the appliance. The shutoff valve shall be within 6 feet (1829 mm) of the appliance, and shall be installed upstream of the union, connector or quick disconnect device it serves. Such shutoff valves shall be provided with access. Shutoff valves serving movable appliances, such as cooking appliances and clothes dryers, shall be considered to be provided with access where installed behind such appliances. Appliance shutoff valves located in the firebox if a fireplace shall be installed in accordance with the appliance manufacturer's instructions. A secondary shutoff valve must be installed within 3 feet (914 mm) of the firebox if appliance shutoff is located in the firebox. Sec. G2421.1 (410.1); change section to read as follows: Sec. G2421.1 (410.1) Pressure regulators. A line pressure regulator shall be installed where the appliance is designed to operate at a lower pressure than the supply pressure. Line gas pressure regulators shall be listed as complying with ANSI Z21.80. Access shall be provided to pressure regulators. Pressure regulators shall be protected from physical damage. Regulators installed on the exterior of the building shall be approved for outdoor installation. Access to regulators shall comply with the requirements for access to appliances as specified in Section M1305. Exception: A passageway or level service space is not required when the regulator is capable of being serviced and removed through the required attic opening. Sec. G2422.1.2.3 (411.1.3.3) Prohibited locations and penetrations; change section by deleting Exceptions 1 and 4 in their entirety. Sec. G2445.2 (621.2); change section to read as follows: Sec. G2445.2 (621.2) Prohibited use. One or more unvented room heaters shall not be used as the sole source of comfort heating in a dwelling unit. Exception: Existing approved unvented room heaters may continue to be used in dwelling units, in accordance with the code provisions in effect when installed, when approved by the building official unless an unsafe condition is determined to exist as described in Section 108.7 of the International Fuel Gas Code. Sec. G2448.1.1 (624.1.1); change section to read as follows: Sec. G2448.1.1 (624.1.1) Installation requirements. The requirements for water heaters relative to access, sizing, relief valves, drain pans and scald protection shall be in accordance with this code. Sec. P2603.3; change section to read as follows: Sec. P2603.3 Protection against corrosion. Metallic piping, except for cast iron, ductile iron and galvanized steel, shall not be placed in direct contact with steel framing members, concrete or cinder walls and floors or other masonry. Metallic piping shall not be placed in direct contact with corrosive soil. Where sheathing is used to prevent direct contact, the sheathing shall have a thickness of not less than 0.008 inch (8 mil) (0.203 mm) and the sheathing shall be made of approved material. Where sheathing protects piping that penetrates concrete or masonry walls or floors, the sheathing shall be installed in a manner that allows movement of the piping within the sheathing. Sec. P2603.5.1; change section to read as follows: Sec. P2603.5.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be a minimum of 12 inches (304 mm) below finished grade at the point of septic tank connection. Building sewers shall be a minimum of 12 inches (304 mm) below grade. Sec. P2604; change by adding Section P2604.2.1 to read as follows: Sec. P2604.2.1 Plastic sewer and DWV piping installation. Plastic sewer and DWV piping installed underground shall be installed in accordance with the manufacturer's installation instructions. Trench width shall be controlled to not exceed the outside the pipe diameter plus 16 inches or in a trench which has a controlled width equal to the nominal diameter of the piping multiplied by 1.25 plus 12 inches. The piping shall be bedded in 4 inches of granular fill and then backfilled compacting the side fill in 6-inch layers on each side of the piping. The compaction shall be to minimum of 85 percent standard proctor density and extend to a minimum of 6 inches above the top of the pipe. Sec. P2801.5.1; change section to read as follows: Sec. P2801.6.1 Pan size and drain. The pan shall be not less than 1½ inches (38 mm) in depth and shall be of sufficient size and shape to receive all dripping or condensate from the tank or water heater. The pan shall be drained by an indirect waste pipe having a diameter of not less than ¾ inch (19 mm). Piping for safety pan drains shall be of those materials listed in Table P2906.5. Multiple pan drains may terminate to a single discharge piping system when approved by the administrative authority and permitted by the manufactures installation instructions and installed with those instructions. Where a pan drain was not previously installed, a pan drain shall not be required for a replacement water heater installation. Sec. P2804.6.1; change section to read as follows: Sec. P2804.6.1 Requirements for discharge piping. The discharge piping serving a pressure relief valve, temperature relief valve or combination thereof shall: 1. Not be directly connected to the drainage system. 2. Discharge through an air gap. 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap. 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment. Exception: Multiple relief devices may be installed to a single T & P discharge piping system when approved by the administrative authority and permitted by the manufactures installation instructions and installed with those instructions. 5. Discharge to an approved location or to the outdoors. 6. Discharge in a manner that does not cause personal injury or structural damage. 7. Discharge to a termination point that is readily observable by the building occupants. 8. Not be trapped. 9. Be installed to flow by gravity. 10. Terminate not more than 6 inches (152 mm) and not less than two times the discharge pipe diameter above the floor or waste receptor flood level rim. 11. Not have a threaded connection at the end of the piping. 12. Not have valves or tee fittings. 13. Be constructed of those materials indicated in Section P2906.5 or materials tested, rated and approved for such use in accordance with ASME A112.4.1. 14. Be one nominal size larger than the size of the relief-valve outlet, where the relief valve discharge piping is installed with insert fittings. The outlet end of such tubing shall be fastened in place. Sec. P2902.5.3; change section to read as follows: Sec. P2902.5.3 Lawn irrigation systems. The potable water supply to lawn irrigation systems shall be protected against backflow by an atmospheric-type vacuum breaker, a pressure type vacuum breaker, a double-check assembly or a reduced pressure principle backflow preventer. A valve shall not be installed downstream from an atmospheric vacuum breaker. Where chemicals are introduced into the system, the potable water supply shall be protected against backflow by a reduced pressure principle backflow preventer. Sec. P3003.9.2; delete exceptions and change sections to read as follows: Sec. P3003.9.2 Solvent cementing. Joint surfaces shall be clean and free from moisture. A purple primer that conforms to ASTM F 656 shall be applied. Solvent cement not purple in color and conforming to ASTM D 2564, CSA B137.3, CSA B181.2 or CSA B182.1 shall be applied to all joint surfaces. The joint shall be made while the cement is wet and shall be in accordance with ASTM D 2855. Solvent cement joints shall be permitted above or below ground. Sec. P3111 Combination waste and vent systems; delete the section in its entirety. Sec. P3112.2 Vent Collection; delete existing section and replace with the following: Sec. P3112.2 Installation. Traps for island sinks and similar equipment shall be roughed in above the floor and may be vented by extending the vent as high as possible, but not less than the drainboard height and then returning it downward and connecting it to the horizontal sink drain immediately downstream from the vertical fixture drain. The return vent shall be connected to the horizontal drain through a wye-branch fitting and shall, in addition, be provided with a foot vent taken off the vertical fixture vent by means of a wye-branch immediately below the floor and extending to the nearest partition and then through the roof to the open air or may be connected to other vents at a point not less than six (6) inches (152 mm) above the flood level rim of the fixtures served. Drainage fittings shall be used on all parts of the vent below the floor level and a minimum slope of one-quarter (¼) inch per foot (20.9 mm/m) back to the drain shall be maintained. The return bend used under the drain-board shall be a one (1) piece fitting or an assembly of a forty-five (45) degree (0.79 radius), a ninety (90) degree (1.6 radius) and a forty-five (45) degree (0.79 radius) elbow in the order named. Pipe sizing shall be as elsewhere required in this Code. The island sink drain, upstream of the return vent, shall serve no other fixtures. An accessible cleanout shall be installed in the vertical portion of the foot vent. Appendix BB Tiny Houses; change the code by adding Appendix BB "Tiny Houses" as mandatory provisions.
(Ord. No. 2016-3-12, § II, 3-14-16; Ord. No. 2018-11-16, § II, 11-26-18, eff. 1-2-19; Ord. No. 2022-1-17, §§ I, II, 1-24-22; Ord. No. 2022-11-4, §§ I, II, 11-14-22; Ord. No. 2025-6-15, § II, 6-9-25)
Ask a question about Plano law
Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.