§ 6-719 — Deletions, additions, amendments
Code of Ordinances, City of Plano, Texas (Supp. No. 153: codified through Ordinance No. 2025-10-2, adopted October 13, 2025) · Plano City Code § 6-719
Corpus is an independent public-information project, not the official City of Plano website. Stable reference: corpuslaw.us/code/1f50bd59-ec85-4abe-a431-f7130ef721b8
Sec. 6-719. - Deletions, additions, amendments.
The following deletions, additions, and amendments to the International Existing Building Code adopted in this division are hereby approved and adopted: Sec. 102.4; change to read as follows: Sec. 102.4 Referenced codes and standards. The codes, when specifically adopted, and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections 102.4.1 and 102.4.2. [Remainder of section unchanged.] Sec. 202; change definition of "Existing Structure" to read as follows: Existing Structure. A building, structure, or space, with an approved final inspection issued under a code edition which is at least 2 published code editions preceding the currently adopted building code; a building, structure, or space that is currently undergoing a change of occupancy or use. Sec. 302.2; amend to read as follows: Sec. 302.2 Additional codes. Alterations, repairs, additions and changes of occupancy to, or relocation of, existing buildings and structures shall comply with the provisions for alterations, repairs, additions and changes of occupancy or relocation, respectively, in this code and the International Energy Conservation Code, International Fire Code, International Fuel Gas Code, International Mechanical Code, International Plumbing Code, International Property Maintenance Code, International Residential Code and NFPA 70 and any other codes or other ordinances adopted by the City. Where provisions of the other codes conflict with provisions of this code, the provisions of this code shall take precedence. Sec. 306.1; change to read as follows: Sec. 306.1 Scope. The provisions of Sections 306.1 through 306.7.16 apply to maintenance and repair, change of occupancy, additions and alterations to existing buildings, including those identified as historic buildings. Exception: Components of projects regulated by and registered with Architectural Barriers Division of Texas Department of Licensing and Regulation shall be deemed to be in compliance with the requirements of this chapter. Sec. 309.2.1 Automated sprinkler systems; delete this section. Sec. 401.3 Flood hazard areas; delete this section. Sec. 405.2.6 Flood hazard areas; delete this section. Sec. 502.2 Flood hazard areas; delete this section. Sec. 503.2 Flood hazard areas; delete this section. Sec. 503.18; change to read as follows: Sec. 503.18 Enhanced classroom acoustics. In Group E occupancies, where the work area exceeds 50 percent of the building area, enhanced classroom acoustics shall be provided in all classrooms with a volume of 20,000 cubic feet (565 m 3 ) or less. Enhanced classroom acoustics shall comply with the reverberation time in Section 808 of ICC A117.1. Exception: Compliance with the Texas Accessibility Standards is not considered equivalent compliance for the purpose of enforcement of this code section. Sec. 504.1.2 change to read as follows: Sec. 504.1.2 Existing fire escapes. Existing fire escapes shall continue to be accepted as a component in the means of egress in existing buildings only. Existing fire escapes shall be permitted to be repaired or replaced. Sec. 504.1.3 New fire escapes; delete this section. Sec. 507.3 Flood hazard areas; delete this section. Sec. 701.3 Flood hazard areas; delete this section. Sec. 702.7; change to read as follows: Sec. 702.7 Materials and methods. All new work shall comply with the materials and methods requirements in the International Building Code, International Energy Conservation Code, International Mechanical Code, National Electrical Code, and International Plumbing Code, as applicable, that specify material standards, detail of installation and connection, joints, penetrations and continuity of any element, component, or system in the building. Sec. 802.5.1; change to read as follows: Sec. 802.5.1 Minimum requirement. Every portion of open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are more than 30 inches (762 mm) above the floor or grade below and are not provided with guards, or those in which the existing guards are judged to be in danger of collapsing, shall be provided with guards. Section 803.1; change to read as follows: 803.1 Scope. The requirements of this section shall be limited to work areas in which Level 2 alterations are being performed, and where specified they shall apply throughout the floor on which the work areas are located or otherwise beyond the work area. For the purpose of fire sprinkler protection and fire alarm requirements included in this section, the work area shall be extended to include at least the entire tenant space or spaces bounded by walls capable of resisting the passage of smoke containing the subject work area, and if the work area includes a corridor, hallway, or other exit access, then such corridor, hallway, or other exit access shall be protected in its entirety on that particular floor level. Sec. 803.2.6; change to read as follows: Sec. 803.2.6 Supervision. Fire sprinkler systems required by this section shall be supervised by one of the following methods: 1. Approved central station system in accordance with NFPA 72. 2. Approved proprietary system in accordance with NFPA 72. 3. Approved remote station system of the jurisdiction in accordance with NFPA 72. 4. Where approved by the code official, approved local alarm service that will cause the sounding of an alarm in accordance with NFPA 72. Exception: Supervision is not required where the Fire Code does not require such for new construction. Sec. 803.3; change section to read as follows (Exceptions also deleted): Sec. 803.3 Standpipes. Refer to Section 1103.6 of the Fire Code for retroactive standpipe requirements. Section 804.2; change to read as follows: Sec. 804.2 General. The means of egress shall comply with the requirements of this section. Exception: Means of egress complying with the requirements of the building code under which the building was constructed shall be considered to be compliant means of egress if, in the opinion of the code official, they do not constitute a distinct hazard to life. Section 804.5.1.2; change to read as follows: Sec. 804.5.1.2 Fire escapes required. For other than Group I-2, where more than one exit is required, an existing fire escape complying with section 805.3.1.2.1 shall be accepted as providing one of the required means of egress. Section 804.5.1.2.1; change to read as follows: Sec. 804.5.1.2.1 Fire escape access and details. Fire escapes shall comply with all of the following requirements: 1. Occupants shall have unobstructed access to the fire escape without having to pass through a room subject to locking. 2. Access to a new fire escape shall be through a door, except that windows shall be permitted to provide access from single dwelling units or sleeping units in Group R-1, R-2 and I-1 occupancies or to provide access from spaces having a maximum occupant load of 10 in other occupancy classifications. 2.1. The window shall have a minimum net clear opening of 5.7 square feet (0.53 m 2 ) or 5 square feet (0.46 m 2 ) where located at grade. 2.2. The minimum net clear opening height shall be 24 inches (610 mm) and net clear opening width shall be 20 inches (508 mm). 2.3. The bottom of the clear opening shall not be greater than 44 inches (1118 mm) above the floor. 2.4. The operation of the window shall comply with the operational constraints of the International Building Code. 3. [Item deleted.] 4. Openings within 10 feet (3048 mm) of fire escape stairways shall be protected by fire assemblies having minimum ¾-hour fire-resistance ratings. Exception: Opening protection shall not be required in buildings equipped throughout with an approved automatic sprinkler system. 5. In all buildings of Group E occupancy up to and including the 12 th grade, buildings of Group I occupancy, boarding houses, and childcare centers, ladders of any type are prohibited on fire escapes used as a required means of egress. Sec. 804.7.2; change to read as follows: Sec. 804.7.2 Transoms. In all buildings of Group B, E, I-1, I-2, R-1, and R-2 occupancies, all transoms in corridor walls in work areas shall be either glazed with ¼-inch (6.4 mm) wired glass set in metal frames or other glazing assemblies having a fire protection rating as required for the door and permanently secured in the closed position or seated with materials consistent with the corridor construction. Sec. 904.1; change to read as follows: Sec. 904.1 Automatic sprinkler systems. An automatic sprinkler system shall be provided in a work area where required by Section 803.2 of this section. For the purpose of fire sprinkler protection and fire alarm requirements included in this section, the work area shall be extended to include at least the entire tenant space or spaces bounded by walls containing the subject work area, and if the work area includes a corridor, hallway, or other exit access, then such corridor, hallway, or other exit access shall be protected in its entirety on that particular floor level. Sec. 904.1.1; change to read as follows: Sec. 904.1.1 High-rise buildings. An automatic sprinkler system shall be provided in work areas of high-rise buildings. Sec. 1011.2.1; change to read as follows: Sec. 1011.2.1 Automatic sprinkler system. The installation of an automatic sprinkler system shall be required where there is a change of occupancy classification and Chapter 9 of the current International Building Code requires an automatic sprinkler system based on the new occupancy or where there is a change of occupancy within the space where there is a different fire protection system threshold requirement in Chapter 9 of the current International Building Code than exists in the current building or space. The installation of the automatic sprinkler system shall be required within the area of the change of occupancy and areas of the building not separated horizontally and vertically from the change of occupancy by a fire barrier or fire wall. Sec. 1103.3 Flood hazard areas; delete the section in its entirety. Sec. 1201.4 Flood hazard areas; delete the section in its entirety. Sec. 1303.1.3 Compliance with flood hazard provisions; delete the section in its entirety. Sec. 1402.6 Flood hazard areas; delete the section in its entirety. Sec. 1502.1; change to read as follows: Sec. 1502.1 Site safety plan. The owner or owner's authorized agent shall be responsible for the development, implementation, and maintenance of an approved, written site safety plan establishing a fire prevention program at the project site applicable throughout all phases of the construction, repair, alteration or demolition work. Any changes to the plan shall address the requirements of this chapter and other applicable portions of the International Fire Code, the duties of staff, and the staff training requirements. The plan shall be submitted for approval in accordance with the International Fire Code, and be approved by the Fire Department before a building permit is issued. Sec. 1502.3.1; change to read as follows: Sec. 1502.3.1 Violations. Failure to properly conduct, document and maintain documentation required by this section shall constitute an unlawful act in accordance with Section 113.1 and shall result in the issuance of a notice of violation by the Fire code official to the site safety director. Upon the third offense, the Fire code official, based on their findings, shall request a stop work order enforcement be implemented to the code official in accordance with Section 114, and work shall not resume until satisfactory assurances of future compliance have been presented to and approved by the code official. Sec. 1512.1 change to read as follows: Sec. 1512.1 When required. An approved water supply for fire protection, either temporary or permanent, shall be made available as soon as combustible material arrives on the site or as determined by the code official. The water supply design and the timing of the water supply installation relative to building construction shall comply with the adopted Fire Code. Sec. 1512.2 Combustible building materials; delete section in its entirety. Sec. 1512.3 Vertical construction of Types III, IV, and V construction; delete section in its entirety. Sec. 1512.3.1 Fire separation up to 30 feet; delete section in its entirety. Sec. 1512.3.2 Fire separation of 30 feet up to 60 feet; delete section in its entirety. Sec. 1512.3.3 Fire separation of 60 feet or greater; delete section in its entirety. Sec. 1512.4 Vertical construction, Types I and II construction; delete section in its entirety. Sec. 1512.5 Standpipe supply; delete section in its entirety.
(Ord. No. 2016-3-6, § I, 3-14-16; Ord. No. 2018-11-17, § II, 11-26-18, eff. 1-2-19; Ord. No. 2022-1-18, § II, 1-24-22; Ord. No. 2025-6-11, § II, 6-9-25)
Ask a question about Plano law
Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.
