§ 9-46 — Plumbing system

Code of Ordinances, City of Plano, Texas (Supp. No. 153: codified through Ordinance No. 2025-10-2, adopted October 13, 2025) · Plano City Code § 9-46

Corpus is an independent public-information project, not the official City of Plano website. Stable reference: corpuslaw.us/code/62aecaef-5095-4c77-8ae7-90a7a1fc8dbc

Sec. 9-46. - Plumbing system.

(a) Materials. (1) Approved. a. A plumbing system and hoses conveying water must be constructed and repaired with approved materials according to law. P b. A water filter must be made of safe materials. P (b) Design, construction, and installation. (1) Approved system and cleanable fixtures. a. A plumbing system must be designed, constructed, and installed according to law. P b. A plumbing fixture such as a handwashing sink, toilet, or urinal must be easily cleanable. (2) Handwashing sink, installation. a. A handwashing sink must be equipped to provide water at a temperature of at least 38°C (100°F) through a mixing valve or combination faucet. Pf b. A steam mixing valve may not be used at a handwashing sink. c. A self-closing, slow-closing, or metering faucet must provide a flow of water for at least fifteen (15) seconds without the need to reactivate the faucet. d. An automatic handwashing facility must be installed in accordance with manufacturer's instructions. (3) Backflow prevention, air gap. An air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment, or nonfood equipment must be at least twice the diameter of the water supply inlet and may not be less than 25 mm (1 inch). P (4) Backflow prevention device, design standard. A backflow or backsiphonage prevention device installed on a water supply system must meet American Society of Sanitary Engineering (A.S.S.E.) standards for construction, installation, maintenance, inspection, and testing for that specific application and type of device. P (5) Conditioning device, design. A water filter, screen, and other water conditioning device installed on water lines must be designed to facilitate disassembly for periodic servicing and cleaning. A water filter element must be of the replaceable type. (6) Water heaters. a. Water heaters must be installed and maintained in accordance with the Plumbing Code. P b. Water heaters must be listed as a commercial unit by an ANSI accredited testing and certification organization and approved by the regulatory authority. c. Residential water heaters are prohibited in retail establishments, except for those facilities providing only commercially pre-packaged food. Pf (c) Numbers and capacities. (1) Handwashing sinks. a. Except as specified in subparagraph b. of this paragraph, at least one (1) handwashing sink, a number of handwashing sinks necessary for their convenient use by employees in areas specified under section 9-46(d)(1), and not fewer than the number of handwashing sinks required by law must be provided. Pf b. If approved and capable of removing the types of soils encountered in the food operations involved, automatic handwashing facilities may be substituted for handwashing sinks in a food establishment that has at least one (1) handwashing sink. (2) Toilets and urinals. At least one (1) toilet and not fewer than the toilets required by law must be provided. If authorized by law and urinals are substituted for toilets, the substitution must be done as specified in law. (3) Service sink. a. At least one (1) service sink or one (1) curbed cleaning facility equipped with a floor drain must be provided and conveniently located for the cleaning of mops or similar wet floor cleaning tools and for the disposal of mop water and similar liquid waste. b. Lavatories, utensil-washing sinks, equipment-washing sinks, food preparation sinks, toilets, urinals, and showers may not be used as a service sink for the disposal of mop water and similar liquid waste. (4) Backflow prevention device, when required. A plumbing system must be installed to preclude backflow of a solid, liquid, or gas contaminant into the water supply system at each point of use at the food establishment, including on a hose bibb if a hose is attached or on a hose bibb if a hose is not attached and backflow prevention is required by law, by: a. Providing an air gap as specified under subsection (b)(3) of this section; P or b. Installing an approved backflow prevention device as specified under subsection (b)(4) of this section. P (5) Backflow prevention device, carbonator. a. If not provided with an air gap as specified under subsection (b)(3) of this section, a dual check valve with an intermediate vent preceded by a screen of not less than 100 mesh to 25.4 mm (100 mesh to 1 inch) must be installed upstream from a carbonating device and downstream from any copper in the water supply line. P b. A dual check valve attached to the carbonator need not be of the vented type if an air gap or vented backflow prevention device has been otherwise provided as specified under subparagraph a. of this paragraph. (6) Food preparation sink. A food preparation sink is required for washing of food if the menu or method of preparation requires soaking, rinsing, culling, or cleaning of raw ingredients or produce. Pf (7) Dump sink. a. At least one (1) waste sink must be provided where bar service or counter service is offered, including but not limited to where blender, coffee, or tea service is performed. b. When a facility is observed using a hand sink as a dump sink in a bar or counter service area at three (3) or more routine inspections in a two-year period, the department may require the facility to install a dump sink in the bar or counter service area. (d) Location and placement. (1) Handwashing sinks. a. A handwashing sink must be located within twenty-five (25) linear feet of food preparation, food dispensing, and warewashing areas convenient for use by employees, and in, or immediately adjacent to, toilet rooms. Pf b. Hand sinks located adjacent to food preparation, food preparation equipment, wares, or food storage areas must be protected with splash guards that are at least as high as the top of the faucet supplying water to the hand sink. Pf c. Any area in which a hand wash sink is located must be unobstructed by doors or equipment, and access must be kept clear to enable its use as required by this Code. Pf (2) Backflow prevention device, location. A backflow prevention device must be located so that it may be serviced and maintained. (3) Conditioning device, location. A water filter, screen, and other water conditioning device installed on water lines must be located to facilitate disassembly for periodic servicing and cleaning. (e) Operation and maintenance. (1) Using a handwashing sink. a. A handwashing sink must be maintained so that it is accessible at all times for employee use. Pf b. A handwashing sink may not be used for purposes other than handwashing. Pf c. An automatic handwashing facility must be used in accordance with manufacturer's instructions. Pf (2) Prohibiting a cross connection. a. A person may not create a cross connection by connecting a pipe or conduit between the drinking water system and a nondrinking water system or a water system of unknown quality. P b. The piping of a nondrinking water system must be durably identified so that it is readily distinguishable from piping that carries drinking water. Pf (3) Scheduling inspection and service for a water system device. A device such as a water treatment device or backflow preventer must be scheduled for inspection and service, in accordance with manufacturer's instructions and as necessary to prevent device failure based on local water conditions, and records demonstrating inspection and service must be maintained by the person in charge. Pf (4) Water reservoir of fogging devices, cleaning. a. A reservoir that is used to supply water to a device such as a produce fogger must be: (1) Maintained in accordance with manufacturer's specifications; P and (2) Cleaned in accordance with manufacturer's specifications or according to the procedures specified under subparagraph b. of this paragraph, whichever is more stringent. P b. Cleaning procedures must include at least the following steps and must be conducted at least once a week: (1) Draining and complete disassembly of the water and aerosol contact parts; P (2) Brush-cleaning the reservoir, aerosol tubing, and discharge nozzles with a suitable detergent solution; P (3) Flushing the complete system with water to remove the detergent solution and particulate accumulation; P and (4) Rinsing by immersing, spraying, or swabbing the reservoir, aerosol tubing, and discharge nozzles with at least 50 MG/L hypochlorite solution. P c. A cleaning log of the procedures identified in this paragraph must be maintained onsite and made available to the department upon request. (5) System maintained in good repair. A plumbing system must be: a. Repaired according to law; P and b. Maintained in good repair.

(Ord. No. 2025-4-2, § 1, 4-14-25)

Ask a question about Plano law

Corpus searches the Plano sections it holds and shows the ones that match, with their citations. Free, no sign-in.