Sec. 44-466. - General.
(a) The city's public works department requires adherence to certain specifications and details for utility installation by microtrenching as set forth in this article. These standards for microtrench construction include width, depth, location, clearance from other existing utilities located in the city rights-of-way or easements, material cover, compaction requirements, backfill specifications and restoration. (b) The use of microtrenching in the roadways will be evaluated based on several key factors, including, but not limited to, roadway classifications (arterials, collectors, or local streets), traffic volumes, signalized intersections, condition/age of existing pavement, existing utility infrastructure and any other site-specific circumstances. The city will only approve the installation of microtrench abutting the lip of gutter on each side of the roadway with a minimum cover of ten inches to the top of existing pavement on local streets and 12 inches on arterial roadways. (c) All fiber must be conduit. There shall be no stacking of conduits or secondary trenches allowed once this space has already been occupied. Perpendicular roadway trench crossings are prohibited without permission from the executive director of the public works department or designee.
(Ord. No. O-2025-255, § I, 10-9-2025)