§ 8-2 — Compatibility buffers
Code of Ordinances, City of Round Rock, Texas (Supp. 27: codified through Ordinance of August 13, 2026 (online updated November 5, 2026)) · Round Rock Zoning and Development Code, art. I, § 8-2
Corpus is an independent public-information project, not the official City of Round Rock website. Stable reference URL
Sec. 8-2. - Compatibility buffers.
(a) Purpose and intent. The purpose of this section is to set forth requirements regarding the design, installation, construction and maintenance of compatibility buffers for all property other than those specifically exempted below. A compatibility buffer shall be composed of a landscape buffer and a compatibility fence as provided below. Compatibility buffering is intended to minimize the effects of SR (Senior), MF-1 (Multifamily - low density), MF-2 (Multifamily - medium density), MF-3 (Multifamily - urban), C-1 (General commercial), C-1a (General commercial-limited), C-2 (Local commercial), OF-1 (Office - Low Rise), BP (Business park), LI (Light industrial), I (Industrial), PF-1 (Public facilities), PF-2 (Public facilities - medium intensity), and PF-3 (Public facilities - high intensity), land uses which share a common lot line with existing or planned single-family or two-family uses, while maintaining the flexibility of allowing such more intense land uses in appropriate circumstances. (b) Applicability. This section shall apply to all land within the city limits and in areas where this section is in effect by contractual agreement. (1) Except as provided in subsection (c) below, the requirements of this section shall apply to: a. Any new development or construction requiring a permit; b. Any change of land use from a residential use to a nonresidential use; or c. Any change, conversion, or addition of commercial land uses that result in an increase in the parking requirements. (c) Exemptions. The following shall be exempt from the requirements of this section: (1) Restoration of a building or structure which has been damaged, destroyed or demolished to an extent less than 50 percent of its fair market value (as determined by the most recent appraisal of land value of the appraisal district in which the building or structure is located); (2) Exterior or interior renovation of a structure; (3) Land located within the central business district; or (4) Lots where the adjacent single-family or two-family property is occupied by a place of worship, civic building such as fire or police station, park, pond, or designated open space. (d) Special exceptions. A landowner may apply for a special exception to be granted by the ZBA to exempt the proposed use from the requirements of this section based on one or more of the following factors: distance to existing residential structures on the abutting single-family or two-family property, likelihood that the abutting single-family or two-family property will be developed into single-family dwelling units if presently vacant, change in elevation, or presence of natural features such as creeks or trees. In order for an exemption to be granted, the ZBA must conduct a public hearing and find that the presence of such factors substantially meets the intent of the compatibility buffer requirement by providing adequate separation or buffering between the proposed use and the single-family or two-family property. (e) Landscape buffer. A landscape buffer at least eight (8) feet wide shall be provided for all sites subject to this section. Based on the linear footage that extends along the length of the property line between higher and lower intensity land uses, the minimum quantity of landscaping shall be determined by the following requirements: (1) One large tree per 50 linear feet with a minimum caliper of three (3) inches, selected from the list of approved evergreen tree species in Appendix B of the Tree Technical Manual; and (2) One medium tree per 50 linear feet with a minimum caliper of two (2) inches, selected from the list of approved evergreen tree species in Appendix B of the Tree Technical Manual; and (3) All trees utilized shall be of an evergreen species. Other than the required landscaping and associated irrigation, nothing shall be placed within the landscape buffer, including without limitation, accessory buildings, parking lots, storage of materials and refuse containers. The landscape buffer may not be used as a utility easement. (f) Compatibility fence. In addition to the above landscaping requirement, a compatibility buffer shall also have a compatibility fence installed and maintained on the applicable property boundaries. Materials and installation of the compatibility fence shall comply with the most recent edition of "Selected ASTM Standards for Fence Materials and Products", a copy of which shall be maintained by the zoning administrator. Structural plans and specifications for fences shall be submitted at the same time as other construction plans required by this section. In approving said plans and specifications, the development services manager shall consider the site's soil characteristics, wind loadings, and other environmental considerations. A landowner may select from two options for complying with the requirements for a compatibility fence required by this section. The options are set forth below: (1) Pre-cast concrete panel or architectural concrete masonry unit (CMU) fence option. a. Fence materials, construction standards, and miscellaneous requirements shall be as follows: 1. Pre-cast concrete panels shall be installed per manufacturer's specifications; 2. Construction details or shop drawings must be sealed by a civil engineer, structural engineer, or landscape architect and provided prior to the issuance of a building permit; 3. Both sides of the fence shall have a finished face; and 4. The fence shall have a minimum height of six (6) feet. (2) Masonry fence option. a. For the purposes of this subsection (e)(2), "masonry fence" shall mean a fence constructed of brick or natural stone. The term shall not include cement-based siding such as HardiePlank, Fencecrete, or similar construction materials. b. Masonry materials, construction standards, and miscellaneous requirements shall be as follows: 1. Brick or natural stone; 2. A cast-in-place structural footing; 3. Top capped; 4. Both sides of the fence shall have a finished face; 5. The fence shall have a minimum height of six (6) feet; and 6. Construction details or shop drawings must be sealed by a civil engineer, structural engineer, or landscape architect, shall include wind load calculations certified by an engineer qualified by experience and/or training in structural evaluation in accordance with the most recently adopted International Building Code, and be provided prior to the issuance of a building permit. c. If a landowner selects the masonry fence option, he shall be entitled to take advantage of reduced setback requirements as set forth in the lot and building dimensional standards table for the applicable zoning district.
