§ 4.04.092 — Adoption and amendments
Code of Ordinances of the City of San Angelo, Texas (Codified through Ordinance No. 2025-103, enacted November 4, 2025. (Supp. No. 10)) · San Angelo Code of Ordinances § 4.04.092
Corpus is an independent public-information project, not the official City of San Angelo website. Stable reference: corpuslaw.us/code/3aee5bdc-51c7-49a3-9c1f-03f365a43817
Sec. 4.04.092 - Adoption and amendments
The following code, as published by the International Code Council, Inc., is hereby adopted by reference as though it were copied herein fully, including all appendices, except where expressly excluded herein: International Residential Building Code, 2021 edition, in its entirety, save and except chapters 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, and appendices AA, AB, AC, AF, AI, AL, AM, AO and AP, and N1101.14 Certificate (Mandatory), and save and except: Section R101.1. Title., which is amended to read as follows: R101.1 Title. These provisions shall be known as the Residential Code for One- and Two-family Dwellings of the City of San Angelo, and shall be cited as such and will be referred to herein as "this code". Table 301.2(1), which is amended to read as follows: Ground Snow Load: five psf Wind Speed: Nominal Design = 90 mph Ultimate Design = 115 mph Seismic Design: Category 0 Weathering: Moderate Frost Line: 12 inches Termite: Slight to Moderate Winter Design Temp: 32 degrees F Ice Barrier Underlayment Required: No Flood Hazards: First Ordinance Adopted, July 27, 1976 Date of Current Map, June 19, 2012 Air Freezing Index: 50 Delete Section R313 Automatic Fire Sprinkler Systems in its entirety. Section R314.3 Location. Smoke alarms shall be installed in the following locations: 1. In each sleeping room. 2. Outside each separate sleeping area within 12 feet of the outside edge of the bedroom door. 3. On each additional story of the dwelling, including basements and habitable attics and not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. 4. Smoke alarms shall be installed not less than 3 feet (914 mm) horizontally from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent placement of a smoke alarm required by this section. 5. In the hallway and in the room open to the hallway in dwelling units where the ceiling height of a room open to a hallway serving bedrooms exceeds that of the hallway be 24 inches or more. Section R315.3 Carbon monoxide alarms - Location Carbon monoxide alarms in dwelling units shall be installed outside of each separate sleeping are within 12 feet of the outside edge of the bedroom door. Where a fuel burning appliance is located within a bedroom or its attached bathroom, a carbon monoxide alarm shall be installed within the bedroom. Section R403.1.6, entitled "Foundation anchorage," which shall instead read as follows: R403.1.6 Foundation anchorage. Wood sill plates and wood walls supported directly on continuous foundations shall be anchored to the foundation in accordance with this section. Cold-formed steel framing shall be anchored directly to the foundation or fastened to wood sill plates anchored to the foundation. Anchorage of cold- formed steel framing and sill plates supporting cold-formed steel framing shall be in accordance with this section and Section R505.3.1 or R603.3.1. Wood sole plates at all exterior walls on monolithic slabs, wood sole plates of braced wall panels at building interiors on monolithic slabs and all wood sill plates shall be anchored to the foundation with minimum ½-inch- diameter anchor bolts spaced a maximum of 6 feet on center or approved anchors or anchor straps spaced as required to provide equivalent anchorage to ½-inch- diameter anchor bolts. Bolts shall be a minimum of 8" long and shall extend a minimum of 5 inches into concrete or grouted cells of concrete masonry units. The bolts shall be located in the middle third of the width of the plate. A nut and washer shall be tightened on each anchor bolt. There shall be a minimum of two bolts per plate section with one bolt located not more than 12 inches or less than seven bolt diameter from each end of the plate section. Interior bearing wall sole plates on monolithic slab foundation that are not part of a braced wall panel shall be positively anchored with approved fasteners. Sill plates and sole plates shall be protected against decay and termites where required by Sections R317 and R318. Exceptions: 1. Walls 24 inches total length or shorter connecting offset braced wall panels shall be anchored to the foundation with a minimum of one anchor bolt located in the center third of the plate section and shall be attached to adjacent braced wall panels at corners as shown in Item 9 of Table R602.3(1). 2. Connection of walls 12 inches total length or shorter connecting offset braced wall panels to the foundation without anchor bolts shall be permitted. The wall shall be attached to adjacent braced wall panels at corners as shown in Item 9 of Table R602.3(1). Section R602.6.1, entitled "Drilling and notching of top plate," which shall instead read as follows: R602.6.1 Drilling and notching of top plate. Where piping or ductwork is placed in or partly in an exterior wall or interior loadbearing wall, necessitating cutting, drilling or notching of the top plate by more than 50 percent of its width, a galvanized metal tie not less than 0.054 inches thick (1.37 mm) (16ga) and 1-1/2 inches (38 mm) wide shall be fastened across and to the plate at each side of the opening with not less than four 8d nails at each side or equivalent. The metal tie must extend not less than 6 inches past the opening. See Figure R602.6.1. Exception: When the entire side of the wall with the notch or cut is covered by wood structural panel sheathing. Table N1102.1.2, and Table N1102.1.3, which shall be changed to read as follows: Table N1102.1.2 (R402.1.2) Equivalent U-Factors Climate Zone | Fenestration U-Factor | Skylight U-Factor | Glazed Fenestration SHGC | Ceiling U-Factor | Frame Wall U-Factor | Mass Wall U-Factor | Floor U-Factor | Basement Wall U-Factor | Slab Wall R-Value & Depth | Crawl Space Wall U-Factor 3 | 30 | 0.55 | 0.30 | .30 | 0.070 | 0.098 | 0.047 | 0.091 | 0 | 0.136 Table N1102.1.3(R402.1.3) Insulation and Fenestration Requirements by Component Climate Zone | Fenestration U-Factor | Skylight U-Factor | Glazed Fenestration SHGC | Ceiling R-Value | Wood Frame Wall R-Value | Mass Wall R-Value | Floor R-Value | Basement Wall R-Value | Slab R-Value & Depth | Crawl Space Wall R-Value 3 | 0.30 | 0.55 | 0.30 | 30 | 15 or 13 + 1 | 5/8 | 19 | 5/13 | 0 | 5/13 N1102.4.1.2 (R402.4.1.2) Testing, which is deleted in its entirety and replaced to read as follows: N1102.4.1.2 Testing - Visual Inspection option. Building envelope tightness and insulation installation shall be considered acceptable when the items listed in Table N1102.4.1.1, applicable to the method of construction, are field verified. Where required by the code official, an approved party independent from the installer of the insulation shall inspect the air barrier and insulation. Delete N1103.1.1 (403.1.1) Programmable thermostat in its entirety N1103.3.5 (R403.3.5) Duct testing, which is deleted in its entirety and replaced to read as follows: N1103.3.5 Duct testing. Duct testing and installation shall be considered acceptable when the prescriptive requirements of Section N1103.3, applicable to the method of construction, are field verified. Where required by the code official, an approved party independent from the installer of the duct system shall inspect the air barrier and insulation. Delete N1104.2 (R404.2) Interior lighting controls in its entirety. Section M1411.3.1.1, entitled "Water level monitoring devices," which shall instead read as follows: M1411.3.1.1 Water level monitoring devices. On down-flow units and all other coils that have no secondary drain and no means to install an auxiliary drain pan, a water-level monitoring device shall be installed inside the primary drain pan. This device shall shut off the equipment served in the event that the primary drain becomes restricted. Externally installed devices and devices installed in the drain line shall be permitted.
(Ord. No. 2018-128, § 2, 10-16-2018; Ord. No. 2023-017, § 1(Exh. A), 2-7-23)
Ask a question about San Angelo law
Corpus searches the San Angelo sections it holds and shows the ones that match, with their citations. Free, no sign-in.
