§ 4.04.151 — Adoption and amendments
Code of Ordinances of the City of San Angelo, Texas (Codified through Ordinance No. 2025-103, enacted November 4, 2025. (Supp. No. 10)) · San Angelo Code of Ordinances § 4.04.151
Corpus is an independent public-information project, not the official City of San Angelo website. Stable reference: corpuslaw.us/code/1a54291b-1c4e-4a83-b058-246242c66107
Sec. 4.04.151 - Adoption and amendments
The following code, as published by the International Code Council, Inc., is hereby adopted by reference as though it were copied herein fully, including all appendices, except where expressly excluded herein: International Plumbing Code, 2021 edition, in its entirety, save and except for Appendix A, and save and except: Section 109.3, entitled "Fee refunds," which shall instead read as follows: 109.3 Fee refunds. The code official shall authorize the refunding of fees as outlined in the fee schedule (Appendix A) of the City of San Angelo Code of Ordinances. Section 305.4.1, entitled "Sewer depth," which shall instead read as follows: 305.4.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be a minimum of 6 inches (101.6 mm) below finished grade at the point of septic tank connection. Building sewers shall be a minimum of 4 inches (101.6 mm) below grade. Section 308.7, entitled "Anchorage," which shall instead read as follows: 308.7 Anchorage. Anchorage shall be provided to restrain drainage piping and water stub-outs from excessive axial movement. Section 312.2, entitled "Drainage and vent water test", which shall instead read as follows: 312.2 Drainage and vent water test. A water test shall be applied to the drainage system either in its entirety or in sections. If applied to the entire system, all openings in the piping shall be tightly closed, except the highest opening, and the system shall be filled with water to the point of overflow. If the system is tested in sections, each opening shall be tightly plugged except the highest openings of the section under test, and each section shall be filled with water, but no section shall be tested with less than a 10-foot head of water. In testing successive sections, at least the upper 10 feet of the next preceding section shall be tested so that no joint or pipe in the building, except the uppermost 10 feet of the system, shall have been submitted to a test of less than a 10-foot head of water. This pressure shall be held for not less than 15 minutes. The system shall then be tight at all points. Exception: A water test shall not be required at the top out inspection. The Permits Division shall document a visual inspection or a water test was performed during the top out inspection, if performed. Section 407.2, entitled "Bathtub waste outlets and overflows", which shall instead read as follows: 407.2 Bathtub waste outlets and overflows. Bathtubs shall be equipped with a waste outlet. The outlets shall be connected to waste tubing or piping not less than one ½ inches in diameter. The waste outlet shall be equipped with a water-tight stopper. Section 410.4, entitled "Substitution", which shall instead read as follows: 410.4 Substitution. Where restaurants provide drinking water in a container free of charge, drinking fountains shall not be required in those restaurants. In other occupancies, where drinking fountains are required, water coolers or bottled water dispensers provided free of charge shall be permitted to be substituted for the first of such required drinking fountains and not more than 50 percent of the remaining required drinking fountains. Section 421.3, entitled "Shower waste outlet," which shall instead read as follows: 421.3 Shower waste outlet. Waste outlets serving showers shall be at least 2 inches (38 mm) in diameter and, for other than waste outlets in bathtubs, shall have removable strainers not less than 3 inches (76 mm) in diameter with strainer openings not less than 0.25 inch (6.4 mm) in minimum dimension. Where each shower space is not provided with an individual waste outlet, the waste outlet shall be located, and the floor pitched so that the waste from one shower does not flow over the floor area serving another shower. Waste outlets shall be fastened to the waste pipe in an approved manner. Section 607.2, entitled "Hot or tempered water supply to fixtures," which shall instead read as follows: 607.2 Hot water supply temperature maintenance. Where the developed length of hot water piping from the source of hot water supply to the farthest fixture exceeds 100 feet, the hot water supply system shall be provided with a method of maintaining the temperature in accordance with Chapter 11 of the International Residential Code. Section 903.1, entitled "Roof extension unprotected," which shall instead read as follows: 903.11 Roof Extension Unprotected. Open vent pipes that extend through a roof shall be terminated not less than 6 inches (152.4 mm) above the roof. Where a roof is to be used for assembly or as a promenade, observation deck, sunbathing deck, or similar purposes, open vent pipes shall terminate not less than 7 feet (2,134 mm) above the roof.
(Ord. No. 2018-128, § 2, 10-16-2018; Ord. No. 2023-017, § 1(Exh. A), 2-7-23)
Ask a question about San Angelo law
Corpus searches the San Angelo sections it holds and shows the ones that match, with their citations. Free, no sign-in.
