§ 4.04.211 — Adoption and amendments

Code of Ordinances of the City of San Angelo, Texas (Codified through Ordinance No. 2025-103, enacted November 4, 2025. (Supp. No. 10)) · San Angelo Code of Ordinances § 4.04.211

Corpus is an independent public-information project, not the official City of San Angelo website. Stable reference: corpuslaw.us/code/89f04a38-59d2-4774-a22c-9efd04f3424f

Sec. 4.04.211 - Adoption and amendments

The following code, as published by the International Code Council, Inc., is hereby adopted by reference as though it were copied herein fully, including all appendices, except where expressly excluded herein: National Electrical Code, 2020 edition, in its entirety, and save and except: Section 210.8(A), Dwelling Units All 125-Volt, single-phase, 15- and 20-ampere which is amended to read as follows: Under 210.8, part A, item (2), add the following exceptions: Exception No. 1: Receptacles that are not readily accessible. Exception No. 2: A single receptacle or a duplex receptacle each for two appliances located within dedicated space for each appliance that, in normal use, is not easily moved from one place to another and that is cord-and-plug connected in accordance with 400.7(A). Receptacles installed under the exceptions to 210.8(A)(2) shall not be considered as meeting the requirements of 210.52(G). Section 210.8(A)(5) "Basements" which is to be deleted. Section 210.8(A)(7) "Sinks" which is which is amended to read as follows: (7) Sinks - where receptacles are installed within 6 feet of the outside edge of the sink. Exceptions: 1. Dishwashers and Disposals Section 210.8(A)(10) "Laundry Areas" which is to be deleted. Section 210.8(D) "Kitchen Dishwasher Branch Circuit" which is to be deleted. Section 210.8(F) "Outdoor Outlets" which is to be deleted. Section 210.12(A) "Dwelling Units" which is amended to read as follows: (A) Dwelling Units. All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets or devices installed in dwelling unit bedroom and bedroom closet shall be protected by any of the means described in 210.12(A)(1) through (6): Section 210.12(D) "Branch circuit extensions or modifications" which is amended to read as follows: Dwelling unit Bedroom and bedroom closet, dormitory units and guest suites. Section 210.52(G)(1) "Garages" which is amended to read as follows: (1) Garages. In each attached garage and in each detached garage with electric power. Section 230.67 Delete this section - Surge Protection Section 300.5, Subsection (D)(3), which is amended to read as follows: (3) Service Conductors. All underground electrical installation shall be marked with red electrical warning ribbon, except for low voltage and communication wiring. Warning ribbon shall be installed under the NEC 2020 Sec. 300.5 subsection D3. Section 406.9(A), "Damp Locations", which is amended to read as follows: (A) Damp Locations. A receptacle installed outdoors in a location protected from the weather or in other damp locations shall have an enclosure for the receptacle that is weatherproof when the receptacle is covered (attachment plug cap not inserted and receptacle covers closed). An installation suitable for wet locations shall also be considered suitable for damp locations. A receptacle shall be considered to be in a location protected from the weather where located under roofed open porches, canopies, marquees, and the like, and will not be subjected to a beating rain or water runoff. Section 406.12, Tamper-Resistant Receptacles, which is amended to read as follows: All 15- and 20-ampere, 125-volt non-locking type receptacles in the areas specified in 406.12(3), (4), (8) shall be listed tamper-resistant receptacles.

(Ord. No. 2018-128, § 2, 10-16-2018; Ord. No. 2023-017, § 1(Exh. A), 2-7-23)

Ask a question about San Angelo law

Corpus searches the San Angelo sections it holds and shows the ones that match, with their citations. Free, no sign-in.