SECTION II: - MONUMENTATION
A. Corner Points. All corner points in any subdivision shall either be set or referenced, or if found so indicated, by or under the supervision of the Registered Public Surveyor preparing the final or record plat. If such corners/monuments are not set or found prior to the submission of the final or record plat for approval by the governing body, then a contract evidencing the agreement must be submitted with said final or record plat. Monuments set or called for, whether artificial or natural, shall represent the footsteps of the surveyor and his professional opinion as to the proper location of the point or corner. B. Artificial Monuments. An artificial monument considered permanent shall be construed as any mark or marker of relative performance that, if left undisturbed, will remain in place for a period of at least twenty-five (25) years. Monuments must be set at sufficient depth to retain a stable and distinctive location and be of sufficient depth to withstand deteriorating forces of nature. All monuments should be set in such fashion as to remain stable against an applied force from any direction of approximately ten (10) pounds for a duration in time of at least ten (10) seconds. C. Monument Material. Material for monuments should be chosen in regard to the terrain and situation that exist at the site of the survey. Consideration must be given the natural erosive forces that will work against the monument for decades to come. The following requirements shall be met: 1. Iron or steel bars or rods for monuments should be a minimum size of one-half inch (½") in diameter by eighteen inches (18") long. Longer bars or rods should be used in soft soil to insure stability of the monument. Where rocky or caliche soils prevent specified length, the rods should be driven to refusal at such depths where it will remain stable against the prescribed force and for the prescribed duration. 2. Iron pipes for monuments should be a minimum of one-half inch (½") inside diameter and eighteen inches (18") long. Longer pipes should be used in soft soil to insure stability of the monument. All iron pipes shall be sized by the inside diameter. Where rocky or caliche soils prevent specified length, the pipe should be driven to refusal at such depths where it will remain stable against the prescribed force and for the prescribed duration. 3. Nonferrous metal monuments should be equal to requirements for iron rods or iron pipes. 4. A cast concrete monument shall be a minimum size of four inches in diameter by eighteen inches in length, with a precise station mark such as a center punch or cross embedded in the cap. Larger concrete monuments should be set in soft or wet soil to insure prescribed stability. 5. Poured-in-place concrete monuments should contain a precise station mark, as in 4. above, and be reinforced with at least one-half inch (½"), or larger, iron rods or pipes and be comprised of no less than one-quarter (¼) cubic foot of concrete. 6. Other monumentation, such as drilled holes, chiseled marks in stone, concrete or steel, punch marks, precast bronze disk, etc., should be of sufficient size, diameter or depth to be definitive, stable and readily identified as a survey marker. Objects upon which such marks or markers are placed should be or a stable and permanent nature, greater than those of iron pipes or iron rods. D. Monument Placement. All lot corners, block corners, beginnings and ending of curves, etc., must be marked or referenced. Monuments of this type, or equivalent thereof, may be chosen by the surveyor responsible for the subdivision; however, the same must be described so that each corner may be identified with certainty from such description. E. Monument Identification. Where possible, all monuments should be identified by marked guard stakes set within twenty-four inches (24") of the corner/monument. Appropriate identifying data should be plainly lettered on the stake and the stake painted or flagged. Stakes should be a minimum of three-quarters of an inch by one and one-half inch by 18 inches (¾" x 1½" x 18") in size and driven firmly into the soil. When guard stakes are impractical, the surveyor should identify the monument with an equivalent method. Monuments may be identified by code numbers or letters for brevity and easy recognition or they may be identified by names of specific corners. F. Control Monuments. There should be control monuments set in each subdivision or section thereof at the ratio of at least two (2) such monuments per block. These monuments shall be situated so that at least one (1) other monument is visible from each monument. 1. The material and placement of these monuments should be carefully chosen by the surveyor, keeping in mind the purpose of same, as provided herein. 2. Each such control monument shall be stamped with identifying information that shall be clearly stated on the final or record map. Sufficient data shall be shown so that these control monuments may be used to reset any lot, block, curve point or corner in the subdivision.
(1959 Code, title 9, ch. 4, ex. A)
Ask a question about San Angelo law
Corpus searches the San Angelo sections it holds and shows the ones that match, with their citations. Free, no sign-in.