§ 2-336 — Interior Parking Garage Lighting Shielding
Code of Ordinances of the City of Sugar Land, Texas (Supp. No. 56: codified through Ordinance No. 2403, adopted June 16, 2026) · Sugar Land Development Code § 2-336
Corpus is an independent public-information project, not the official City of Sugar Land website. Stable reference: corpuslaw.us/code/abf895eb-9727-4333-a3c9-de503a49c163
Sec. 2-336. - Interior Parking Garage Lighting Shielding.
Due to the typical partially-open nature of a parking garage structure, in order to reduce unwanted light glare from interior lights that could project outside the structure (see Diagram 1), interior light placement within the parking garage structure shall be shielded to reduce glare in 1 or a combination of the following ways: A. Garage Structural Shielding. If flush-mounted or pendant lighting fixtures are utilized, which extend the light lens down from the ceiling, the lowest portion of the lens shall not be mounted lower than adjacent structural beams of the parking garage ceiling. The purpose of the placement being not lower than the beams is to reduce lighting glare that would otherwise project out from each side of the light lens. (See Diagram 2) B. Full Cut-Off Style Shielding. If pendant lighting fixtures are utilized, which extend the light lens down from the ceiling, and the lowest portion of the lens is mounted lower than adjacent structural beams of the parking garage ceiling, shielding shall be required on all sides of the light lens to make the lighting full cut-off. The purpose of the shielding is to reduce lighting glare that would otherwise project out from each side of the light lens (Diagram 3). Diagram 1—Lighting Glare Example—Parking Garage Interior Lighting (No shielding) [image omitted; see the official code] Diagram 2—Garage Structural Shielding—Parking Garage Interior Lighting (With light recessed above garage ceiling beam depth for reduced glare) [image omitted; see the official code] Diagram 3—Full Cut-Off Style Shielding—Parking Garage Interior Lighting (full cut-off fixture, with light shielded on all sides of fixture for reduced glare if extending below garage ceiling beams, or if parking garage does not have the exposed beam depth to adequately shield light fixture.) [image omitted; see the official code] C. For wall-mounted lighting within the interior of a parking garage structure, the wall-mounted lighting is required to consist of a full cut-off fixture, in which the light lens does not project lower than the shielding, to reduce glare. D. The requirements of Section 2-336 A, B, and C are not applicable for interior garage lighting located within a completely enclosed parking garage level.
(Ord. No. 2185, § 1, 1-21-2020)
Ask a question about Sugar Land law
Corpus searches the Sugar Land sections it holds and shows the ones that match, with their citations. Free, no sign-in.