Sec. 3-88. - Mobile food unit fire safety requirements.
Mobile food units will be inspected annually by the city's fire marshal's office. Mobile food units that only prepare and serve ice cream, Italian ice, or similar foods that do not use gas, diesel, or electric generators, or produce smoke or grease-laden vapors, will be exempted from the annual fire inspection and applicable fee. To receive a city-issued medallion or participate in a special event, mobile food units must comply with the following fire regulations: (a) Storage of flammable and combustible liquids must occur in a UL or FM approved flammable liquid safety container and at a city-approved location. (b) MFUs must be equipped with the following: (1) Portable fire extinguishers selected and installed in accordance with NFPA 10 with a minimum 2A:10BC rating. An approved Class K fire extinguisher must be provided for protection of grease cooking fires. All fire extinguishers must have a current inspection/service tag from a licensed fire extinguishing company. (2) A Type 1 hood installed where cooking appliances produce grease or smoke as a result of the cooking process. (3) Beginning on October 1, 2019, an automatic fire extinguishing system installed to protect cooking equipment. (c) Compressed Gas LPG/CNG: (1) LP-Gas systems for MFUs must comply with NFPA 58. (2) LP-Gas containers installed on vehicles must not exceed 200-gallon aggregate water capacity and each container cannot exceed 100 gallons. (3) Disconnected LP-Gas cylinders may not be transported or stored inside the vehicle. (4) The LP-Gas supply system must be installed on the outside of the vehicle or in a recess or cabinet that is vapor tight to the inside of the vehicle but accessible from and vented to the outside with vents located near the top and bottom of the enclosure. (5) LP-Gas containers must be mounted to prevent jarring loose and slipping or rotating, and the fastenings must be designed and constructed to withstand static loading in any direction equal to four times the weight of the container when filled with fuel. (6) The LP-Gas containers must be installed above the height of the bumper and positioned in an upright position and in a manner that will reduce the exposure from vehicle impact. (7) Only containers designed, constructed, tested, and marked in accordance with the U.S. Department of Transportation specifications, Title 49, Code of Federal Regulations can be used. (8) Main shutoff valves on LP-Gas containers must be readily accessible. There must be a quarter-turn manual gas ball valve installed within the LP-Gas piping for emergency shutoff use and must be installed on the exterior of the vehicle and readily accessible. The quarter-turn valve must be labeled with signage stating "EMERGENCY SHUT-OFF" or similar approved signage with minimum 1-inch lettering. The signage can either be white letters with red background or red letters with white background. (9) Regulators must be installed in accordance with NFPA 58 as well as the manufactures instructions. (10) Piping must be installed in accordance with NFPA 58. The fixed piping system must be designed, installed, supported, and secured to minimize the possibility of damage due to vibrations, strains, or wear and to preclude any loosening while in transit. (11) A flexible connector must be installed between the regulator outlet and the fixed piping system as well as between the cylinder and the gas regulator to protect against expansion, contraction, jarring and vibration. (12) Piping systems, including hose, must be pressure tested and proven free of leaks in accordance with NFPA 58. (13) The operator of the MFU must perform a manual leak test after making connection to a cylinder. (14) A listed LP-gas alarm must be installed, in accordance with manufacturer's instructions, within the mobile food unit in the vicinity of the LP gas system components. (15) Where CNG systems are provided for cooking purposes, the maximum aggregate capacity of CNG containers transported on the vehicle must not exceed 1,300 pounds (590 kg) water capacity. (16) CNG containers must be securely mounted and restrained to prevent movement. Containers must not be installed in locations subject to a direct vehicle impact. (17) CNG system piping, including valves and fittings, must be adequately protected to prevent tampering, impact damage, and damage from vibration. (18) Where CNG containers and systems are used to supply fuel for cooking purposes in addition to being used for transportation, the containers and systems must be installed in accordance with NFPA 52. (19) A listed methane gas alarm must be installed, in accordance with the manufacturer's instructions within the mobile food unit. (20) "No Smoking" signs must be visible near gas cylinders. (d) Cooking appliances: (1) Cooking appliances must be constructed and secured in place. (2) Grease must be regularly removed from all cooking equipment, including the ventilation system. (3) Gas-fired cooking appliances must be equipped with shutoffs in accordance with NFPA 58. (e) Generator/electrical: (1) Refueling of fuel tanks for generators may only occur during non-operating hours. (2) Portable generators must be separated from the public by barriers. (3) All electrical appliances, fixtures, equipment, and wiring must comply with NFPA 70. Improper use of electrical accessories and overloading of circuits is prohibited.
(Ord. No. 2136, § 1, 9-18-2018; Ord. No. 2258, § 9, 7-5-2022)
Ask a question about Sugar Land law
Corpus searches the Sugar Land sections it holds and shows the ones that match, with their citations. Free, no sign-in.