For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-24 — Utility Easements and Services

Code of Ordinances of the City of Sugar Land, Texas (Supp. No. 56: codified through Ordinance No. 2403, adopted June 16, 2026) · Sugar Land Development Code § 5-24

Corpus is an independent public-information project, not the official City of Sugar Land website. Stable reference: corpuslaw.us/code/6a2d24bf-461b-4703-8286-c287b07efcb9

Sec. 5-24. - Utility Easements and Services.

A. All utility easements for water, sanitary sewer, and storm sewer must be shown on the Final Plat. B. Where a subdivision is traversed by a watercourse, ditch, drainage way, or channel, the subdivider must provide a storm sewer easement or drainage Right-of-Way conforming substantially with the course and of such additional width as may be designated by the City or Fort Bend County Drainage District, subject to determination using proper engineering considerations. Maintenance easements must be specified. C. All lots, tracts and reserves shall be served by public water, sanitary sewer and storm sewer. These public improvements shall be designed, constructed, inspected, and accepted according to the latest edition of the Design Standards, Comprehensive Plan, Water and Wastewater Master Plan, and any other applicable plans approved for the area by the City, or the utility district's utility plans, whichever is applicable. D. All utility service lines for residential distribution for electricity, telephone, gas, cable television and any other such service shall be underground with the exception of electric major transmission (three-phase lines) or feeder lines. These lines shall be located on the perimeter of a subdivision whenever possible, but not along street Rights-of-Way. It is recommended that commercial developments have an underground feed from the nearest power line for individual service. The standards for easement requirements for utility service lines are stated in this Section. E. Easements must conform to the following regulations: 1. Water Related Easements. a. Fire hydrants located outside of a street Right-of-Way or water line easement must be placed in a 10-foot by 10-foot easement. Water lines leading and connecting to fire hydrants that are not adjacent to a Right-of-Way must be public and placed within a minimum 10-foot easement. b. Water lines leading and connecting to fire hydrants shall be placed within Landscaped areas in order to provide maintenance access. The City Engineer may consider a Specific Approval to deviate from this standard where unique, site-specific constraints exist. c. Water meters 2 inches and smaller in diameter may be set in a street Right-of-Way or water line easement. d. Water meters larger than 2 inches in diameter must be set in a 10-foot by 20-foot water meter easement. Variations for the placement of multiple meters require specific approval. e. Water mains located in easements not adjacent to street Rights-of-Way must be centered in a 16-foot wide easement. f. Water lines located between 2 single-family homes may be centered in a 10-foot wide easement if the line is cased in C900 casing from the front building line to within 15 feet of the rear lot line, leaving non-cased pipe at the rear lot line, and having gate valves on both ends of the line in order to isolate the section. g. Water lines, except at a flush valve, located in a street Right-of-Way less than 5 feet from the street Right-of-Way line must have a water line easement adjoining the street Right-of-Way. Easements adjoining a street Right-of-Way for water lines smaller than 12 inches in diameter must have a minimum width of 5 feet. Easements adjoining a street Right-of-Way for water lines 12 inches or greater in diameter must have a minimum width of 10 feet. 2. Sanitary Sewer Easements. a. Rear lot sanitary sewer lines are not permitted in new residential developments. b. The minimum width of a sanitary sewer easement is 16 feet. c. The preferred location for sanitary sewers is in the street Right-of-Way. Sanitary sewers placed at a depth of less than 10 feet below grade and within 5 feet of the edge of a street Right-of-Way must have an exclusive 5-foot sanitary sewer easement adjoining the street Right-of-Way or easement. Sanitary sewers placed at a depth equal to or greater than 10 feet below grade and within 5 feet of the edge of street Right-of-Way must have an exclusive 10-foot sanitary sewer easement adjoining the street Right-of-Way or easement. d. Easements for force mains of all sizes must have a minimum width of 16 feet for a single force main when the force main is not located adjacent to a street Right-of-Way. When the force main is located in an easement adjacent to a street Right-of-Way, the force main must be located at the center of a 10-foot wide easement. When the force main is located less than 5 feet from the street Right-of-Way line within the street Right-of-Way, the force main must have an easement adjacent to the street Right-of-Way with a minimum width of 5 feet. e. Sanitary sewer mains, trunk or force mains must be located so that the centerline of the pipe is at least 7½ feet from the edge of the easement. f. Where sanitary sewers or force mains are installed in easements separated from street Rights-of-Way by other private or utility company easements, the sanitary sewer easement must be extended along or across the private utility company easement to provide access for maintenance of the sewer or force main. g. Combined storm and sanitary sewer easements must have the minimum widths as required for storm sewer easements below. When placed in a combined storm and sanitary sewer easement, sanitary sewer mains, trunk or force mains must be located so that the centerline of the pipe is not less than 7½ feet from the edge of the easement. h. For combined storm and sanitary sewer easements located adjacent to public Rights-of-Way where the sanitary sewer is located along the outside of the easement, the centerline of the sanitary sewer pipe must be located at least 7½ feet from the edge of the easement. 3. Storm Sewer Easement. a. Storm sewers located in an easement adjacent to a street Right-of-Way or other public easement must have a minimum easement width of 10 feet. b. Storm sewers not located in an easement adjacent to a street Right-of-Way or other public easement must have a minimum easement width of 20 feet. All storm sewers must be constructed in the center of the easement. c. Storm sewers with a diameter or width greater than 10 feet but less than 15 feet have a minimum easement width of 25 feet. d. The City Engineer will determine the minimum easement width for a storm sewer greater than 15 feet in diameter or width. e. Storm sewers with a flow line depth between 15 feet and 20 feet must have a minimum easement width of 40 feet. f. Storm sewers with a flow line depth greater than 20 feet must have a minimum easement width of 50 feet and require a specific approval through the process outlined in the Design Standards. g. Storm sewers must be located so that there is at least 5 feet from the outside edge of the storm sewer to the edge of the easement. h. When approvals are granted for a special use or combination easement along a side or back lot line, the minimum easement width is 25 feet. 4. Drainage Maintenance Easements. a. All dry detention basins shall have a maintenance easement for drainage dedicated around the detention facility. The easement shall include a maintenance strip measured from top of bank to a width defined in the table below (see Table 5-24.1 and Figure 5-24.A). Table 5-24.1: Maintenance Easement Requirements for Dry Detention Ponds Depth of Detention Facility | Maintenance Strip Width Less than 7 ft. | 15 ft. 7 ft. or greater than | 30 ft. [image omitted; see the official code] Figure 5-24.A b. All wet ponds and amenity lakes shall have a maintenance easement for drainage dedicated around the drainage facility. The easement shall include a maintenance strip measured from top of bank to a width defined in the table below (see Table 5-24.2 and Figure 5-24.B). Table 5-24.2: Maintenance Easement Requirements for Wet Detention Ponds / Amenity Lakes Depth of Drainage Facility | Maintenance Strip Width Less than 6 ft. | 15 ft. 6 ft. to 9 ft. | 20 ft. Greater than 9 ft. | 25 ft. [image omitted; see the official code] Figure 5-24.B 5. Public Dry Utilities. a. Dry utility easements shall comply with requirements set forth by applicable utility companies. Easements may be split equally between 2 adjoining lots. Except as otherwise specified by the utility companies: 1) Electric, phone and cable services require a minimum easement of 14 feet, 2) Street lights require a minimum easement of 5 feet, and 3) Call boxes require a minimum easement of 5 feet.

Ask a question about Sugar Land law

Corpus searches the Sugar Land sections it holds and shows the ones that match, with their citations. Free, no sign-in.