§ 7-38 — Code Amendments
Code of Ordinances of the City of Sugar Land, Texas (Supp. No. 56: codified through Ordinance No. 2403, adopted June 16, 2026) · Sugar Land Development Code § 7-38
Corpus is an independent public-information project, not the official City of Sugar Land website. Stable reference: corpuslaw.us/code/27f41e92-017c-40c8-89a6-7a6d40015091
Sec. 7-38. - Code Amendments.
The following sections of the International Plumbing Code are amended as follows: Section 101.1 is amended to read as follows: 101.1. Title. These regulations shall be known as the International Plumbing Code of the City of Sugar Land, hereinafter referred to as "this code". Subsection 103.1 is amended to read as follows: 103.1. Enforcement authority. The official in charge of the implementation, administration, and enforcement of this code will be known as the code official. Section 104.6 is amended to read as follows: 104.6. Notices and orders. The code official may issue all necessary notices or orders to ensure compliance with this code. Section 105 is amended by adding Subsection 105.6 to read as follows: 105.6. Insurance Required. As a condition to the issuance of the permit, the contractor shall certify that the contractor has: Workers' Compensation insurance as required by law; general liability insurance of at least $100,000.00 for any one accident for property damage and $300,000.00 for any one person for injuries or death; and $5,000.00 for medical expenses for any one person. Paragraph 114.6.1 is amended to read as follows: 114.6.1. Authority to condemn equipment. Where the code official determines that any plumbing, or portion thereof, regulated by this code has become hazardous to life, health or property or has become unsanitary, the code official may order in writing that such plumbing either be removed or restored to a safe or sanitary condition. A time limit for compliance with such order may be specified in the written notice. A person shall not use or maintain defective plumbing after receiving such notice. In cases of immediate danger to life or property, such disconnection shall be made immediately without such notice. Paragraph 114.6.3 is amended to read as follows: 114.6.3. Connection after order to disconnect. A person shall not make connections from any energy, fuel, power supply or water distribution system or supply energy, fuel or water to any equipment regulated by this code that has been disconnected or ordered to be disconnected by the code official or the use of which has been ordered to be discontinued by the code official until the code official authorizes the reconnection and use of such equipment. Where any plumbing is maintained in violation of this code, the code official may institute any appropriate action to prevent, restrain, correct or abate the violation. Paragraph 305.4.1 is amended to read as follows: 305.4.1. Sewer depth. Building sewers that connect to private sewage disposal systems shall be installed not less than 12 inches (mm) below finished grade at the point of septic tank connection. Building sewers shall be installed not less than 12 inches (mm) below grade. Paragraph 504.7.2 is amended to read as follows: 504.7.2. Pan drain termination. The pan drain shall extend full size and terminate over a suitably located indirect waste receptor or floor drain or extend to the exterior of the building and terminate not less than 6 inches (152 mm) and not more than 24 inches (610 mm) above the adjacent ground surface. Where a pan drain was not previously installed, a pan drain shall not be required for a replacement water heater installation if a water leak detection device with an audible alarm is installed inside the pan. Paragraph 605.2.1 is amended to read as follows: 605.2.1. Lead content of drinking water pipe and fittings. The use of pipes and pipe fittings that contain more than 0.25% lead or solders and flux that contain more than 0.2% lead is prohibited for installation or repair of any public water supply and for installation or repair of any plumbing in a residential or nonresidential facility providing water for human consumption and connected to a public drinking water supply system. This requirement may be waived for lead joints that are necessary for repairs to cast iron pipe. Subsection 705.10.2 is amended by deleting the enumerated exception, to read as follows: 705.10.2. Solvent cementing. Joint surfaces shall be clean and free from moisture. A purple primer that confirms to ASTM F656 shall be applied. Solvent cement not purple in color and conforming to ASTM D2564, CSA B137.3, CSA B181.2 or CSA B182.1 shall be applied to all joint surfaces. The joint shall be made while the cement is wet and shall be in accordance with ASTM D2855. Solvent-cement joints shall be permitted above or below ground. Paragraph 903.1.1 is amended to read as follows: 903.1.1 Roof extension unprotected. Open vent pipes that extend through a roof shall be terminated not less than 6 inches (mm) above the roof.
(Ord. No. 2395, § 7, 1-20-26)
Ask a question about Sugar Land law
Corpus searches the Sugar Land sections it holds and shows the ones that match, with their citations. Free, no sign-in.
