§ 7-48 — Code Amendments
Code of Ordinances of the City of Sugar Land, Texas (Supp. No. 56: codified through Ordinance No. 2403, adopted June 16, 2026) · Sugar Land Development Code § 7-48
Corpus is an independent public-information project, not the official City of Sugar Land website. Stable reference: corpuslaw.us/code/97d732ab-b542-4e8b-9547-00c70960430c
Sec. 7-48. - Code Amendments.
The following parts of the International Residential Code are amended: Subsection R101.1 is amended to read as follows: R101.1. Title. These regulations shall be known as the Residential Code for One and Two Family Dwellings of the City of Sugar Land, and shall be cited as such and will be referred to hereinafter as "this code." Subsection R103.1 is amended to read as follows: R103.1. Enforcement authority. The official in charge of the implementation, administration, and enforcement of this code will be known as the building official. Subsection R104.6 is amended to read as follows: R104.6. Notices and orders. The building official may issue necessary notices or orders to ensure compliance with this code. Subsection R105.1 is amended to read as follows: R105.1. Required. It shall be unlawful for any owner, owner's authorized agent, person, firm, or corporation to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure, or erect, install, enlarge, alter, repair, remove, convert, or replace any electrical, gas, mechanical, or plumbing system regulated by this code, or cause any such work to be performed, without obtaining the required permit prior to commencing such work. Each day the violation exists will constitute a separate and distinct violation. It is presumed that the record owner of the property caused the construction, enlargement, alteration, repair, movement, demolition, or change of the occupancy of the building or structure, or the erection, installation, enlargement, alteration, repair, removal, conversion, or replacement of any electrical, gas, mechanical, or plumbing system regulated by this code, or caused the same to be done, on the property. Subsection R105.2 is amended to read as follows: R105.2. Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of the city. Permits shall not be required for the following: Building: 1. Painting, papering, tiling, carpeting, cabinets, counter tops and similar finish work. 2. Prefabricated swimming pools that are less than 24 inches (610 mm) deep. 3. Swings and other playground equipment. 4. Decks not exceeding 200 square feet (18.58 m 2) in area, that are not more than 30 inches (762 mm) above grade at any point, are not attached to a dwelling do not serve the exit door required by Section R311.4. 5. Solar pergolas. Electrical: 1. Listed cord-and-plug connected temporary decorative lighting. 2. Reinstallation of attachment plug receptacles but not the outlets therefor. 3. Replacement of branch circuit overcurrent devices of the required capacity in the same location. 4. Electrical wiring, devices, appliances, apparatus or equipment operating at less than 25 volts and not capable of supplying more than 50 watts of energy. 5. Minor repair work, including the replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles. Gas: 1. Portable heating, cooking or clothes drying appliances. 2. Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe. 3. Portable-fuel-cell appliances that are not connected to a fixed piping system and are not interconnected to a power grid. Mechanical: 1. Portable heating appliances. 2. Portable ventilation appliances. 3. Portable cooling units. 4. Steam, hot- or chilled-water piping within any heating or cooling equipment regulated by this code. 5. Replacement of any minor part that does not alter approval of equipment or make such equipment unsafe. 6. Portable evaporative coolers. 7. Self-contained refrigeration systems containing 10 pounds (4.54 kg) or less of refrigerant or that are actuated by motors of 1 horsepower (746 W) or less. 8. Portable-fuel-cell appliances that are not connected to a fixed piping system and are not interconnected to a power grid. Plumbing: 1. The stopping of leaks in drains, water, soil, waste or vent pipe; provided, however, that if any concealed trap, drainpipe, water, soil, waste or vent pipe becomes defective and it becomes necessary to remove and replace the same with new material, such work shall be considered as new work and a permit shall be obtained and inspection made as provided in this code. 2. The clearing of stoppages or the repairing of leaks in pipes, valves or fixtures and the removal and reinstallation of water closets, provided such repairs do not involve or require the replacement or rearrangement of valves, pipes or fixtures. Section R105 is amended by adding Subsection R105.10 to read as follows: R105.10. Insurance Required. As a condition to the issuance of the permit, the contractor shall certify that the contractor has: Workers' Compensation insurance as required by law; general liability insurance of at least $100,000.00 for any one accident for property damage and $300,000.00 for any one person for injuries or death; and $5,000.00 for medical expenses for any one person. Subsection R113.1 is amended to read as follows: R113.1. Unlawful acts. It shall be unlawful for any person, firm or corporation to erect, construct, alter, extend, enlarge, repair, move, remove, demolish, occupy, or use any building, structure, or equipment regulated by this code, or cause the same to be done, in conflict with or in violation of any of the provisions of this code. Each day the violation exists will constitute a separate and distinct violation. It is presumed that the record owner caused the erection, construction, extension, enlargement, alteration, repair, movement, demolition, occupancy, or use of the building, structure, or equipment, or caused the same to be done, on the property. It is presumed that any building, structure, or equipment present on the property is being used by the record owner or occupant of the property. Subsection R302.2 is amended to read as follows: R302.2. Townhouses. Common walls separating townhouses shall be assigned a fire-resistance rating in accordance with Section R302.2. The common wall shared by two townhouses shall be constructed without plumbing or mechanical equipment, ducts or vents in the cavity of the common wall. The wall shall be rated for fire exposure from both sides and shall extend on and be tight against exterior walls and the underside of the roof sheathing. Electrical installations shall be in accordance with Chapters 34 through 43. Penetrations of the membrane of common walls for electrical outlet boxes shall be in accordance with Section R302.4. Exception: Where a fire sprinkler system in accordance with NFPA 13D is required, the common wall shall not be less than 2-hour fire resistance rated wall assembly tested in accordance with ASM or UL. Paragraph R311.2.2 is amended to read as follows: R311.2.2 Alterations, repairs and additions. Where alterations, repairs or additions requiring a permit occur, the individual dwelling unit shall be equipped with carbon monoxide alarms located as required for new dwellings. Exceptions: 1. Work involving the exterior surfaces of dwellings, such as the replacement of roofing or siding, or the addition or replacement of windows or doors, or the addition of a porch or deck. 2. Installation, alteration or repairs of plumbing systems that are not fuel fired. 3. Installation, alteration or repairs of mechanical systems that are not fuel fired. Subsection G2417.4 is amended to read as follows: G2417.4(406.4) Test pressure measurement. Test pressure shall be measured with a manometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. Spring type test gauges are not permitted. The source of pressure shall be isolated before the pressure tests are made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the scale is not greater than five times the test pressure. Paragraph P2603.5.1 is amended to read as follows: P2603.5.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be not less than 12 inches (mm) below finished grade at the point of septic tank connection. Building sewers shall be not less than 12 inches (mm) below grade. Paragraph P2801.5.1 is amended to read as follows: P2801.5.1 Pan size and drain. The pan shall be not less than 11/2 inches (38 mm) deep and shall be of sufficient size and shape to receive dripping or condensate from the tank or water heater. The pan shall be drained by an indirect waste pipe of not less than 3/4-inch (19 mm) diameter. Piping for safety pan drains shall be of those materials indicated in Table P2906.5. Where a pan drain was not previously installed, a pan drain shall not be required for a replacement water heater installation if a water leak detection device with an audible alarm is installed inside the pan. Section E3803 is amended by amending Table E3803.1 to read as follows: TABLE E3803.1 (Table 300.5) MINIMUM COVER REQUIREMENTS, BURIAL IN INCHES a, b, c, d, e, LOCATION OF WIRING METHOD OR CIRCUIT | TYPE OF WIRING METHOD OR CIRCUIT 1 Direct Burial Cables or Conductors | 2 Rigid Metal Conduit or Intermediate Metal Conduit | 3 Nonmetallic Raceways Listed for Direct Burial Without Concrete Encasement or Other Approved Raceways | 4 Residential Branch Circuits Rated 120 Volts or Less With GFCI protection and Maximum Overcurrent Protection of 20 Amperes | 5 Circuits for Control of Irrigation and Landscape Lighting Limited to Not More Than 30 Volts and Installed with Type UF or in Other Identified Cable or Raceway All locations not specified below | 24 h | 6 | 18 | 12 | 6 f, g In trench below 2-inch-thick concrete or equivalent | 18 h | 6 | 12 | 6 | 6 Under a building | 0 (In raceway only or Type MC identified for direct burial) | 0 | 0 | 0 (In raceway only or Type MC identified for direct burial) | 0 (In raceway only or Type MC identified for direct burial) Under minimum of 4-inch-thick concrete exterior slab with no vehicular traffic and the slab extending not less than 6 inches beyond the underground installation | 18 h | 4 | 4 | 6 (Direct burial) 4 (In raceway) | 6 (Direct burial) 4 (In raceway) Under streets, highways, roads, alleys, driveways and parking lots | 24 h | 24 | 24 | 24 | 24 One- and two-family dwelling driveways and outdoor parking areas, and used only for dwelling-related purposes | 18 h | 18 | 18 | 12 | 18 In solid rock where covered by minimum of 2 inches concrete extending down to rock | 2 (In raceway only) | 2 | 2 | 2 (In raceway only) | 2 (In raceway only) For SI: 1 inch = 25.4 mm. a. Raceways approved for burial only where encased concrete shall require concrete envelope not less than 2 inches thick. b. Lesser depths shall be permitted where cables and conductors rise for terminations or splices or where access is otherwise required. c. Where one of the wiring method types listed in columns 1 to 3 is combined with one of the circuit types in columns 4 and 5, the shallower depth of burial shall be permitted. d. Where solid rock prevents compliance with the cover depths specified in this table, the wiring shall be installed in metal or nonmetallic raceway permitted for direct burial. The raceways shall be covered by a minimum of 2 inches of concrete extending down to the rock. e. Cover is defined as the shortest distance in inches (millimeters) measured between a point on the top surface of any direct-buried conductor, cable, conduit or other raceway and the top surface of finished grade, concrete, or similar cover. f. A lesser depth shall be permitted where specified in the installation instructions of a listed low-voltage lighting system. g. A depth of 6 inches shall be permitted for pool, spa, and fountain lighting that is installed in a nonmetallic raceway, limited to not more than 30 volts and part of a listed low-voltage lighting system. h. Direct buried cables and conductors shall be installed in an approved conduit or raceway.
(Ord. No. 2395, § 8, 1-20-26)
Ask a question about Sugar Land law
Corpus searches the Sugar Land sections it holds and shows the ones that match, with their citations. Free, no sign-in.
