§ 7-58 — Code Amendments
Code of Ordinances of the City of Sugar Land, Texas (Supp. No. 56: codified through Ordinance No. 2403, adopted June 16, 2026) · Sugar Land Development Code § 7-58
Corpus is an independent public-information project, not the official City of Sugar Land website. Stable reference: corpuslaw.us/code/e1808b6f-99c7-4458-ae4d-b0fba2743b5f
Sec. 7-58. - Code Amendments.
The following sections of the International Fire Code are amended: Subsection 101.1 is amended to read as follows: 101.1. Title. These regulations shall be known as the Fire Code of the City of Sugar Land, hereinafter referred to as "this code." Subsection 103.1 is amended to read as follows: 103.1. General. The department of fire prevention is established within the city under the direction of the fire marshal, hereafter referred to in this code as the fire code official. The function of the department shall be the implementation, administration and enforcement of the provisions of this code. Paragraph 105.3.5 is amended to read as follows: 105.3.5. Posting the permit. Issued permits shall be maintained in printed paper form on the premises designated therein at all times and shall be readily available for inspection by the fire code official. Subsection 105.5 is amended to read as follows: 105.5. Required operational permits. The fire code official is authorized to issue operational permits for the operations set forth in Sections 105.5.2 through 105.5.59. Subparagraph 105.5.58 is added to read as follows: 105.5.58. Places of Custodial Care. An operational permit is required for Group R-3 and R-4 Occupancies that provide custodial care. Occupancies include care facilities, congregate care, congregate living facilities, alcohol and drug centers, assisted living facilities, group homes, halfway houses, and community homes for persons with disabilities. Paragraph 105.5.59 is added to read as follows: 105.5.59. Kitchen suppression systems. An operational permit is required for any automatic fire-extinguishing system protecting cooking appliances in commercial food service operations. Paragraph 105.6.26 is added to read as follows: 105.6.26. Electronic Access Control Device. A construction permit is required for the installation of or modification to electronic access control device or related equipment. Maintenance performed in accordance with this code is not considered to be a modification and does not require a construction permit. Subsection 106.4 is amended to read as follows: 106.4. Construction documents on site. One set of approved construction documents, in printed paper form, shall be kept at the job site at all times while work is in progress and shall be available for all required inspections. The documents shall be of sufficient size and clarity to reflect the scope of the work and shall be readily accessible to the fire code official for verification and inspection. Subsection 113.4 is amended to read as follows: 113.4. Violation penalties. Persons who knowingly violate a provision of this code or fail to comply with any of the requirements thereof or who erect, install, alter, repair or do work in violation of the approved construction documents or directive of the fire code official, or of a permit or certificate used under the provisions of this code, shall be guilty of a misdemeanor and will be punished as authorized in section 1-9 of the Development Code, as amended therein and thereafter. Section 202 is amended by adding a definition for "electronic access control device" to read as follows: ELECTRONIC ACCESS CONTROL DEVICE. An electronic or computer-based device, including a telephone entry system, that allows access or controls egress in any occupancy classification. Subsection 307.2 is amended to read as follows: 307.2. Permit required. A permit must be obtained from the fire code official in accordance with Section 105.5 prior to kindling a fire for recognized silvicultural or range wildlife management practices, prevention or control of disease or pests, bonfire, recreational fire or controlled burning as allowed by the Texas Commission on Environmental Quality. Paragraph 307.6 is added to read as follows: 307.6. Rubbish burning. The burning of rubbish shall be prohibited. For the purposes of this section, rubbish includes plastic, rubber, and other materials defined as rubbish in section 202 of this code. Paragraph 308.1.7 is amended to read as follows: 308.1.7. Sky lanterns. Sky lanterns are prohibited. The Exceptions to Paragraph 503.1.1 is amended by adding Subparagraphs (1.4) and (1.5) to read as follows: (1.4) Group U and other accessory use buildings, five hundred (500) square feet or less, may be located more than fifty (50) feet but not more than five hundred (500) feet from an access roadway, provided the code official determines that the conditions are such that firefighting operations will not be obstructed. (1.5) The width of access roadways accessing one- and two-family dwellings, which are located more than one hundred fifty (150) feet but less than five hundred (500) feet from a public street, shall not be less than twelve (12) feet wide. Subsection 503.3 is amended to read as follows: 503.3. Marking. Where required by the fire code official, approved signs or other approved notices shall be provided for fire apparatus access road to identify such roads or prohibit the obstruction thereof. Signs or notices shall be maintained in a clean and legible condition at all times and be replaced or repaired when necessary to provide adequate visibility. Fire lane markings shall be in accordance with Appendix D of this chapter. It is unlawful for any person to occupy, continue to occupy, or make use of any building until the requirements for fire lane markings applicable to the real property where the building is located have been met. Subsection 503.4 is amended to read as follows: 503.4. Obstruction of fire apparatus access roads. Fire apparatus access roads shall not be obstructed in any manner. The minimum widths and clearances established in Paragraphs 503.2.1 and 503.2.2 shall be maintained at all times. For any unattended motor vehicle that is stopped or parked in a fire apparatus access road, it is presumed that the registered owner of the vehicle is the person who stopped or parked the vehicle at the time and place the offense occurred. Paragraph 603.5.2 is amended by deleting the enumerated exceptions, to read as follows: 603.5.2. Application and use. Relocatable power taps and current taps shall be directly connected to a permanently installed receptacle. Subsection 903.2 is amended to read as follows: 903.2. Where required. Approved automatic fire sprinkler systems shall be provided in new buildings and structures and in existing buildings and structures in the locations listed below and where otherwise described in this code. 1. All new buildings where the fire area exceeds five thousand (5,000) square feet. For the purposes of this provision, a fire wall does not delineate a separate building. 2. In existing buildings, if any addition results in a gross fire area of more than five thousand (5,000) square feet or raises the building height beyond two stories. For the purposes of this provision, the addition of a fire wall does not delineate a separate building nor does it eliminate the requirement for fire sprinkler protection. 3. In existing buildings where the fire area exceeds five thousand (5,000) square feet, when thirty (30) percent or more of the building undergoes renovation in one or more phases. The addition of a fire wall does not delineate a separate building nor does it eliminate the requirement for fire sprinkler protection. Subparagraphs 903.2.1.1 through 903.2.1.4 are amended to read as follows: 903.2.1.1. Group A-1. An automatic sprinkler system shall be provided throughout stories containing Group A-1 occupancies and throughout all stories from the Group A-1 occupancy to and including the levels of exit discharge serving that occupancy where one of the following conditions exists: 1. The fire area exceeds 5,000 square feet (464.5 m2) or the building is greater than one story in height. 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. 4. The fire area contains a multiple-theater complex. 903.2.1.2. Group A-2. An automatic sprinkler system shall be provided throughout stories containing Group A-2 occupancies and throughout all stories from the Group A-2 occupancy to and including the levels of exit discharge serving that occupancy where one of the following conditions exists: 1. The fire area exceeds 5,000 square feet (464.5 m2) or the building is greater than one story in height. 2. The fire area has an occupant load of 100 or more. 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. 903.2.1.3. Group A-3. An automatic sprinkler system shall be provided throughout stories containing Group A-3 occupancies and throughout all stories from the Group A-3 occupancy to and including the levels of exit discharge serving that occupancy where one of the following conditions exists: 1. The fire area exceeds 5,000 square feet (464.5 m2) or the building is greater than two stories in height. 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. 903.2.1.4. Group A-4. An automatic sprinkler system shall be provided throughout stories containing Group A-4 occupancies and throughout all stories from the Group A-4 occupancy to and including the levels of exit discharge serving that occupancy where one of the following conditions exists: 1. The fire area exceeds 5,000 square feet (464.5 m2) or the building is greater than two stories in height. 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. Paragraph 903.2.4 is amended to read as follows: 903.2.4. Group F-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group F-1 occupancy where the fire area exceeds 5,000 square feet (464.5 m2). Paragraph 903.2.7 is amended to read as follows: 903.2.7. Group M. An automatic sprinkler system shall be provided throughout buildings containing a Group M occupancy where the Group M fire area exceeds 5,000 square feet (464.5 m2). Paragraph 903.2.9 is amended to read as follows: 903.2.9. Group S-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group S-1 occupancy where the fire area exceeds 5,000 square feet (464.5 m2). Subparagraph 903.2.9.1 is amended to read as follows: 903.2.9.1. Repair garages. An automatic sprinkler system shall be provided throughout all buildings used as repair garages where the fire area exceeds 5,000 square feet (464.5 m2), in accordance with Section 406.8 of the Building Code. Paragraph 903.2.10 is amended to read as follows: 903.2.10. Group S-2 enclosed parking garages. An automatic sprinkler system shall be provided throughout buildings classified as enclosed parking garages in accordance with Section 406.6 of the Building Code whether either of the following conditions exist: 1. Where the fire area of the enclosed parking garage, subject to Section 406.6 of the Building Code, exceeds 5,000 square feet (464.5 m2). 2. Where the enclosed parking garage is located beneath and/or attached to other occupancy groups. 3. Where the open parking garage, subject to Section 406.5 of the Building Code, exceeds 48,000 square feet (4460m2). Subparagraph 903.2.11.3 is amended to read as follows: 903.2.11.3 Buildings 35 feet or more in height. An automatic sprinkler system shall be installed throughout buildings that have one or more stories located 35 feet (10668 mm) or more above the lowest level of fire department vehicle access, measured to the finished floor. Clause 903.3.1.2.3 is amended to read as follows: 903.3.1.2.3 Attics. Attic protection shall be provided as follows: 1. Attics that are used or intended for living purposes or storage shall be protected by an automatic sprinkler system. 2. Where fuel-fired equipment is installed in an unsprinklered attic, not fewer than one quick-response intermediate temperature sprinkler shall be installed above the equipment. 3. Where located in a building of Type III, Type IV or Type V construction designed in accordance with Section 510.2 or 510.4 of the International Building Code, attics not required by Item 1 to have sprinklers shall comply with one of the following if the roof assembly is located more than 55 feet (16 764 mm) above the lowest level of fire department vehicle access needed to meet the provisions in Section 503: 3.1. Provide automatic sprinkler system protection. 3.2. Provide a heat detection system throughout the attic that is arranged to activate the building fire alarm system. 4. Groups R-3 and R-4, Condition 2 occupancy attics not required by Item 1 to have sprinklers shall comply with one of the following: 4.1. Provide automatic sprinkler system protection. 4.2. Provide a heat detection system throughout the attic that is arranged to activate the building fire alarm system. 5. Group R-2 occupancy attics not required by Item 1 to have sprinklers shall comply with one of the following: 5.1. Provide automatic sprinkler system protection. 5.2. Provide a heat detection system throughout the attic that is arranged to activate the building fire alarm system. Paragraph 903.4.3 is amended to read as follows: 903.4.3. Alarms. Approved audible devices shall be connected to every automatic sprinkler system. Such sprinkler water flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. An electric/water bell shall be provided on the exterior of the building, in an approved location. When water flow supervision is provided, alarm devices shall be located within the interior of the building to provide an internal evacuation signal throughout the building in all common areas and areas accessible to the public. Group R-1, R-2 and condominiums shall be provided with an alarm signal device in each unit to provide an internal evacuation signal separate and distinct from the security system. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm system. Paragraph 904.15 is amended to read as follows: 904.15. Domestic cooking facilities. Cooktops and ranges installed in the following occupancies shall be in accordance with section 904.15.1. 1. In Group I-1 occupancies where domestic cooking facilities are installed in accordance with Section 420.9 of the International Building Code. 2. In Group I-2 occupancies where domestic cooking facilities are installed in accordance with Section 407.2.7 of the International Building Code. 3. In Group R-2 occupancies where domestic cooking facilities are installed in accordance with Section 420.11 of the International Building Code. 4. In Group R-3 and R-4 occupancies where domestic cooking operations are conducted for the residents. Subsection 5608.1 is amended to add Paragraph 5608.1.1 to read as follows: 5608.1.1. Fireworks. The possession, manufacture, storage, sale, handling and use of fireworks are prohibited within the city limits of Sugar Land, Texas. It shall be unlawful for any person to manufacture or sell fireworks within the City of Sugar Land corporate limits. Except as herein provided, it shall be unlawful for any person to assemble, possess, store, transport, receive, keep, sell, offer or have in his or her possession with the intent to sell, use, discharge, ignite, detonate, fire or otherwise put in action any fireworks of any description. Exception: The use of approved fireworks for display as permitted in Section 5608. Subsection 5608.2 is amended to read as follows: 5608.2. Permit application. Prior to issuing permits for fireworks display, plans for the display, inspections of the display site and demonstrations of the display operations shall be approved and all applicable state and federal permits shall have been obtained. The applicant for the display shall, at the time of making application, furnish proof that he or she carries compensation insurance for his employees as provided for by laws of this state and he or she shall file with the code official, for approval, a certificate of insurance evidencing the carrying of public liability insurance, including bodily injury liability, in limits of not less than one hundred thousand dollars ($100,000.00) for each person and one million dollars ($1,000,000.00) for each accident, issued by an insurance company authorized to conduct business in this state for the benefit of the person named therein as insured as evidence of ability to respond in damages in at least the above amounts. For each display of fireworks under this section, standby personnel and equipment from the Sugar Land Fire Department shall be required. The number of personnel and equipment to be in attendance shall be determined by the Fire Marshal. The expense of such personnel and equipment at the display shall be paid in advance by the applicant prior to the issuance of the permit. The fee charged for each standby fire engine and crew shall be as specified in the appropriate fee schedule of the City of Sugar Land. Fees for other required personnel shall be based on actual cost. Subsections D103.1, D103.5, D103.6, and D107.1 of Appendix D are amended to read as follows: D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 24 feet, exclusive of shoulders. Figure D103.1 Dead-End Fire Apparatus Access Road Turnaround [image omitted; see the official code] D103.6 Signs. Where required by the fire code official, fire apparatus access roads shall be marked in one of the following manners: 1. CURB PAINTING - Curbs along fire lanes shall be painted red with white letters stating "FIRE LANE TOW AWAY ZONE" and/or "FIRE LANE NO PARKING" painted at intervals not exceeding every 50' feet. The letters shall not be less than four inches tall. 2. FLAT SURFACE (NO CURB) - A red six (6) inch stripe, with markings indicated in Paragraph 1 above, shall be placed along the outer edges of the pavement along the fire lane. 3. Free standing signs placed along the fire lane. The design and placement of signs shall be in accordance with figure D 103.6. Signs shall have a minimum dimension of 12 inches wide by 18 inches high and have red letters on a white reflective background. Signs shall be posted on one or both sides of the fire apparatus road as required by Paragraphs D103.6.1 or D103.6.2. Figure D103.6 Fire Lane Marking Standard Signage [image omitted; see the official code] [image omitted; see the official code] [image omitted; see the official code] [image omitted; see the official code] D107.1 One- or two-family dwelling residential developments. Developments of one- or two- family dwellings where the number of dwelling units exceeds 75 shall be provided with separate and approved fire apparatus access roads and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 75 dwelling units on a single public or private fire apparatus access road and all dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Subparagraphs 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the International Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official.
(Ord. No. 2395, § 10, 1-20-26)
Ask a question about Sugar Land law
Corpus searches the Sugar Land sections it holds and shows the ones that match, with their citations. Free, no sign-in.