Sec. 7-59.7. - Code Amendments.

The following sections of the International Energy Conservation Code are amended as follows: Subsection 101.1 is amended to read as follows: 101.1. Title. These regulations shall be known as the International Energy Conservation Code of the City of Sugar Land, hereinafter referred to as "this code." Paragraph C104.1.2 is added to read as follows: C104.1.2. Alternative compliance. A building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance with the energy efficiency requirements of this section may, at the option of the code official, be considered in compliance. The United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. Paragraph R104.1.2 is added to read as follows: R104.1.2. Alternative compliance. A building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance with the energy efficiency requirements of this section may, at the option of the code official, be considered in compliance. The United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. Regardless of the program or the path to compliance, each 1- and 2-family dwelling shall be tested for air and duct leakage as prescribed in Section R402.4.1.2 and R403.3.3 respectively. Subsection R405.2 is amended by amending Table R405.2 to read as follows: TABLE R405.2 REQUIREMENTS FOR TOTAL BUILDING PERFORMANCE SECTION a | TITLE General R401.3 | Certificate Building Thermal Envelope R402.1.1 | Vapor retarder R402.1.6 | Rooms containing fuel-burning appliances R402.2.3 | Attic knee wall R402.2.4 | Eave baffle R402.2.5.1 | Access hatches and door insulation installation and retention R402.2.10 | Slab-on-grade floors R402.2.11 | Crawl space walls R402.5.1.1 | Installation R402.5.1.2 | Air leakage testing R402.5.1.3 | Maximum air leakage rate R402.5.2 | Fireplaces R402.5.3 | Fenestration air leakage R402.5.4 | Recessed lighting R402.5.5 | Air-sealed electrical and communication outlet boxes R402.6 | Maximum fenestration U-factor and SHGC Mechanical R403.1 | Controls R403.2 | Hot water boiler temperature reset R403.3 | Duct systems R403.4 | Mechanical system piping insulation R403.5 | Service hot water systems R403.6 | Mechanical ventilation R403.7, except Section R403.7.1 | Equipment sizing and efficiency rating R403.8 | Systems serving multiple dwelling units R403.9.2 | Snow melt and ice system controls R403.10 | Energy consumption of pools and spas R403.11 | Portable spas R403.12 | Residential pools and permanent residential spas R403.13 | Gas fireplaces Electrical Power and Lighting Systems R404.1 | Lighting equipment a. Reference to a code section includes all the relative subsections except as indicated in the table. Subsection 406.2 is amended by amending Table R406.2 to read as follows: TABLE R406.2 REQUIREMENTS FOR ENERGY RATING INDEX SECTION a | TITLE General R401.3 | Certificate Building thermal envelope R402.1.1 | Vapor retarder R402.1.6 | Rooms containing fuel-burning appliances R402.2.4 | Eave baffle R402.2.5.1 | Access hatches and door insulation installation and retention R402.2.10 | Slab-on-grade floors R402.2.11 | Crawl space walls R402.5.1.1 | Installation R402.5.1.2 | Air leakage testing R402.5.1.3 | Maximum air leakage rate R402.5.2 | Fireplaces R402.5.3 | Fenestration air leakage R402.5.4 | Recessed lighting R402.5.5 | Air-sealed electrical and communication outlet boxes R406.3 | Building thermal envelope Mechanical R403.1 | Controls R403.2 | Hot water boiler temperature reset R403.3 | Duct systems R403.4 | Mechanical system piping insulation R403.5 | Service hot water systems R403.6 | Mechanical ventilation R403., except Section R403.7.1 | Equipment sizing and efficiency rating R403.8 | Systems serving multiple dwelling units R403.9.2 | Snow melt and ice system controls R403.10 | Energy consumption of pools and spas R403.11 | Portable spas R403.12 | Residential pools and permanent residential spas R403.13 | Gas fireplaces Electrical Power and Lighting Systems R404.1 | Lighting equipment a. Reference to a code section includes all of the relative subsections except as indicated in the table. Paragraph R402.5.5 is amended to read as follows: R402.5.5. Electrical and communication outlet boxes (air-sealed boxes). Electrical and communication outlet boxes installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.

(Ord. No. 2395, § 11, 1-20-26)

Ask a question about Sugar Land law

Corpus searches the Sugar Land sections it holds and shows the ones that match, with their citations. Free, no sign-in.