§ 10-21 — Exceptions, amendments and deletions to the International Fire Code, 2024 Edition, including appendices B, C, D, F, I, K, N, and O; adopted in section 10-20

Code of Ordinances of the City of Waco, Texas (Supp. No. 88: codified through Ordinance No. 2026-250, enacted April 21, 2026) · Waco City Code § 10-21

Corpus is an independent public-information project, not the official City of Waco website. Stable reference: corpuslaw.us/code/bc17bbf1-2bc6-4670-bb7a-749ec8a76a2f

Sec. 10-21. - Exceptions, amendments and deletions to the International Fire Code, 2024 Edition, including appendices B, C, D, F, I, K, N, and O; adopted in section 10-20

The following exceptions, amendments and deletions are hereby made to the International Fire Code adopted in section 10-20: (1) IFC Section 112 Means of Appeals shall be replaced with: An appeal shall be pursuant to Section 10-24 of Article II "Fire Codes" of Chapter 10 "Fire Protection and Prevention" of the Code of Ordinances of the City of Waco, Texas. (2) Section 310.3.1 is added to state: Section 310.3.1. "No Smoking" signs shall be of cardboard, metal or cloth, and not less than six inches by 16 inches in size. Lettered upon such signs shall be the words "No Smoking" which shall be not less than four inches in vertical length, and the words "By Order of the Fire Marshal" shall be in letters at least one-half inch in vertical length. No owner, manager, operator, supervisor or other person having charge of any building or premises listed in subsection (a) of this section shall fail to have posted "No Smoking" signs at the places designated by the fire marshal after having received three days' notification to erect such signs. (3) IFC Section 322.4 Battery charging areas shall be changed to read: Where approved, powered micromobility devices are permitted to be charged in a room or area that complies with all of the following: 1. Only listed devices utilizing listed charging equipment shall be permitted to be charged. 2. Is provided with sufficient electrical receptacles to allow the charging equipment for each device to be directly connected to a receptacle. Extension cords and relocatable power taps shall not be used. 3. Storage of combustible materials, combustible waste or hazardous materials shall not be permitted. 4. The charging operation shall not be conducted in or obstruct any required means of egress. 5. Removable storage batteries shall not be stacked or charged in an enclosed cabinet unless the cabinet is specially designed and approved for such purpose. 6. A minimum distance of 36 inches shall be maintained between each removable storage battery during charging operations unless each battery is isolated from neighboring batteries by an approved fire-resistant material. 7. A minimum of 36 inches shall be maintained between the location of the battery on each powered micromobility device during charging operations. 8. The indoor room or area shall be protected by a fire alarm system utilizing air-aspirating smoke detectors or radiant energy-sensing fire detection. (4) IFC Section 323 Electric Vehicles is added to state: 323 Electric Vehicles (EVs). 323.1 EV Charging Stations Located Inside. Electric vehicle (EV) charging stations shall not be located inside buildings and/or structures, except where approved for parking garage locations as per the National Electrical Code and this code. 323.1.1 EV Charging Stations Inside Parking Garage. A parking space within a parking garage that is provided with an EV charging port must comply with at least one of the following: 1. Sprinkler system. Install a fire sprinkler system designed per NFPA 13 Extra Hazard Group II (EH2) with 0.40 GPM/SF over the parking space(s) associated with EV charging station(s). The EH2 design area(s) are required to extend minimum 3-feet beyond the perimeter of the parking space(s). 2. Fire-rated wall. The parking space(s) associated with EV charging station(s) must be separated from all other areas within the garage/building by a minimum of two-hour fire-rated wall separation on the driver side and passenger side, the length of the parking space, and to within 24 inches below the bottom of the structure. The access must maintain the minimum code required access distances required by Chapter 10 of the IBC. 3. Distance. The parking space(s) associated with EV charging station(s) must be located at least 10 feet from any building, fire pumps, generators, transformers, utility rooms containing critical equipment, means of egress, or parking space. 323.1.2 Location of Charging Stations Inside Parking Garage. EV charging stations located in parking garages must be located at grade level along the exterior perimeter walls and within 150 feet of fire apparatus access roadway, or located on the top level of the garage with no roof or structure above. 323.2 Disconnect. Locations containing electric vehicle charging stations must have a clearly identified and readily accessible emergency disconnect installed in an approved location. The emergency disconnects for exterior electric vehicle charging stations must be within 100 feet (30 480 mm) of, but not less than 20 feet (6096 mm), from the charging stations, unless otherwise approved by the fire code official. 323.2.1 Height. The height of the emergency disconnect switch must be at least 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the activating button. 323.2.2 Emergency Disconnect Sign. Emergency disconnect devices must be distinctly labeled as: "EMERGENCY ELECTRIC VEHICLE CHARGER DISCONNECT." Signs must be placed in an approved location and include all of the following: 1. White reflective background with red letters. 2. Weather-resistant durable material. 3. Lettering not less than 2 inches (51 mm) high. 4. Permanently affixed to the building or structure in an approved manner. (5) Section 503.2.1 Dimensions, shall be changed to read: Fire apparatus access roads shall have an unobstructed width of not less than 26 feet (7925 mm), unless given approval from AHJ, exclusive of shoulders, except for approved security gates in accordance with Section 503.6, and an unobstructed vertical clearance of not less than 13 feet 6 inches (4115 mm). (6) Section 503.3.1 is added to state: On public property, the fire lane shall be marked with free standing signs that may be supplemented by curb or pavement markings; however, curb or pavement markings are not required. (7) Section 503.3.2 is added to state: On privately owned property, the proper markings to designate a fire lane shall be one of the following: (a) Signs: Shall read "NO PARKING FIRE LANE" and shall be 12 inches wide and 18 inches high. Signs shall be painted on a white background with letters and borders in red, using not less than two inch lettering. Signs shall be permanently affixed to a stationary post and the bottom of the sign shall be six feet six inches above finished grade. Signs shall be spaced not more than twenty-five (25) feet apart, or up to fifty (50) feet apart if pavement or curb markings are also used. Signs may be installed on permanent buildings or walls if approved by the fire marshal. Also, the fire marshal may allow a variance to sign marking styles where access to the property is limited or restricted by means of gates or barriers. A written request with full architectural details shall be submitted to the fire marshal for review. (b) Pavement markings: Shall be marked by painted lines of red traffic paint six inches in width to show the boundaries of the lane. The words "NO PARKING FIRE LANE" shall appear in four inch white letters at 20 foot intervals on the red border marking along both sides of the fire lanes. (c) Curb markings: Shall be painted in red traffic paint from the top seam of the curb to a point even with the driving service. The words "NO PARKING FIRE LANE" shall appear in four inch white letters at 20 foot intervals along the curb(s). (8) Section 503.3.3 is added to state: Existing signs and markings for fire lanes shall be brought into compliance with this section within 180 days of the adoption of this section, unless the fire marshal approves the existing signs and markings at the location or extends the time for compliance for the specific location. (9) Section 503.3.4 is added to state: All fire lanes shall be maintained and kept in a good state of repair at all times by the owner, and the City shall not be responsible for the maintenance of fire lanes, except those on property owned and controlled by the City. It shall further be the responsibility of the owner to ensure that all fire lane markings required by this section be kept so that the border of each and every portion of the fire lane is easily distinguishable by the public. (10) Section 503.3.5 is added to state: No owner or person in charge of any premises served by a fire lane shall abandon or close any fire lane without first obtaining the approval of the fire marshal. (11) Section 503.3.6 is added to state: It shall be unlawful for any person to stop, stand, or park a vehicle, or to allow a vehicle owned by him to stop, stand, or park, within any fire lane, on either public or private property. Persons who park a vehicle or allow a vehicle to be stopped, stood or parked in such area, be it on public or private property, may be cited for and charged with a violation by any person authorized to enforce the Code of Ordinances. Persons authorized to enforce this provision may include a private security guard as provided in section 25-198. Proof that a person owned a vehicle shall constitute prima facie proof that the person parked the vehicle or allowed the vehicle to be parked in such area. (12) Section 903.2.8. The following exception is added to this section: Exceptions: One and two family dwellings.

(Ord. No. 2001-55, § 2, 9-4-01; Ord. No. 2004-0543, § 3, 9-21-04; Ord. No. 2009-602, § 1, 10-20-09; Ord. No. 2013-571, § 1, 9-17-13; Ord. No. 2014-023, § 3, 1-7-14; Ord. No. 2016-437, § 1, 7-5-16; Ord. No. 2021-086, § 1, 2-2-21; Ord. No. 2025-813, § 1, 11-4-25)