§ 28-880.7 — Building design specifications
Code of Ordinances of the City of Waco, Texas (Supp. No. 88: codified through Ordinance No. 2026-250, enacted April 21, 2026) · Waco City Code § 28-880.7
Corpus is an independent public-information project, not the official City of Waco website. Stable reference: corpuslaw.us/code/bd0cc1bf-ca39-49d9-b037-579479db9b3b
Sec. 28-880.7. - Building design specifications.
(a) Awnings. Awnings may encroach over the sidewalk to within four feet of the curb depending on the proximity to features such as traffic signals, lampposts, and street trees and must clear the sidewalk vertically by a minimum of eight feet, subject to approval from building official. (b) Boarded-up windows. Boarded-up windows on the first floor of a building façade that fronts on a street are prohibited, except as follows: (1) Buildings that have been determined to be unrepairable and tagged accordingly by inspection services. (2) Time of compliance: a. Existing buildings with boarded-up windows on the first floor will have six months from the effective date of this division to comply with the regulations herein. b. Existing buildings with boarded-up windows along Elm Avenue and Bridge Street will have 24 months from the effective date of this division to comply with the regulations herein. (3) Nothing in this section shall preempt enforcement of any city ordinance or state law with respect to the regulation of unsafe structures. (c) Building height. (1) The minimum height for a one-story building shall be 22 feet. (2) The maximum height for a building on an infill lot shall be no more than three stories above the tallest building on the block-face. (3) The interior height of the first floor of a commercial use structure shall be a minimum of 12 feet from finished floor to finished ceiling for any new buildings and/or buildings undergoing substantial renovation. (d) Building set back. (1) The build-to-line shall be zero for 80 percent of the width of the building's façade on a front street and for 30 percent of a building's façade on a side street. Exceptions to this requirement may be permitted where angle parking adjoining the street is constructed on private property, subject to the approval of the directors of planning and engineering services. (2) Structures on an infill lot shall match the build-to-line of the existing adjacent building that is built closest to the property line. (e) Building width. The maximum building width for an infill lot shall be no wider that the widest existing building on the block-face, except in circumstances where the enforcement of this provision may result in the creation of unusable land parcels. (f) Façade glazing. All façades shall be glazed with clear glass at a rate of no less than 30 percent on the ground floor for any new buildings and/or buildings undergoing substantial renovation. (g) Ground floor finish level. (1) The maximum ground floor finish level for a commercial use structure shall be six inches above the sidewalk, except that properties located in the floodplain are subject to the additional requirements of section 11-62. (2) The maximum ground floor finish level for a residential use structure shall be 36 inches above the sidewalk, except where topography of a lot requires lower/higher finish floor levels. (h) Loading and service entries. Loading and service entries may not face the street for any new buildings and/or buildings undergoing substantial renovation. (i) Metal buildings. Pre-engineered metal buildings shall not be permitted. (j) Primary entrance location. The primary entrance location shall be on the front building façade facing the street for any new buildings and/or buildings undergoing substantial renovation. (k) Private frontage. Private frontage may be in the form of a terrace or dooryard, forecourt, stoop, shopfront and awning, gallery or arcade.
(Ord. No. 2009-367, § 4, 7-7-09)
Ask a question about Waco law
Corpus searches the Waco sections it holds and shows the ones that match, with their citations. Free, no sign-in.