Sec. 6-29. - Exception, amendments, and deletions to the International Residential Code, 2024 Edition, including appendices BB, BD, BO, and NE.
(1) IRC Part VIII—Electrical Chapters 34-43 shall be deleted. (2) IRC Section R108.2. Schedule of Permit Fees shall read: On buildings, structures, electrical, gas, mechanical, and plumbing systems or alterations requiring a permit, a schedule of fees for building permits issued by the City of Waco shall be approved by the city council. A copy of the permit fee schedule shall be on file with the city secretary and building official. A permit shall not be issued nor any amendment made to a permit until the fees prescribed under this section have been paid. (3) IRC Section R112. Means of Appeals shall be replaced in its entirety with: An appeal shall be pursuant to Division 2, "Building Inspections Advisory and Appeals Board" of Article I "In General" of Chapter 6 "Buildings and Building Regulations" of the Code of Ordinances of the City of Waco. (4) IRC Section R309.2 One and two family dwellings automatic sprinkler systems shall be deleted. (5) IRC Chapter 11 [RE] Energy Efficiency shall be deleted and IRC Chapter 11 [RE] Energy Efficiency (2018 Edition) shall be added in its entirety. (6) IRC Section M1401.1.1 Air conditioning equipment shall be added to read: (a) All residential dwelling units shall be designed and installed with an air conditioning system with the ability to condition and maintain conditioned air at least 15 degrees cooler than the outside temperature, but in no event higher than 85°F in each habitable room. (b) The required room temperature shall be measured 3 feet (914mm) above the floor near the center of the room and 2 feet (610mm) inward from the center of each exterior wall. (c) Air conditioning system is not required to condition air below 70°F. (7) IRC G2417.7.3.1 (406.7.3.1), Abandoned fuel gas piping,shall read: Where fuel gas piping is removed from service for an indefinite time period, it shall be purged and capped (8) IRC Section P2603.5.1, Sewer depth, shall read: Building sewers shall be installed below grade and have a minimum of six inches of cover measured from finished grade to top of pipe. (9) IRC Section P2903.11 Hose Bibb shall be deleted. (10) IRC Appendix NE 101.2 (RE 101.2), Electric vehicle power transfer infrastructure, shall read: New residential automobile parking spaces for residential buildings may be provided with electric vehicle power transfer infrastructure in accordance with Sections NE 101.2.1 through NE 101.2.5.
(Ord. No. 2004-0714, 12-7-04; Ord. No. 2005-532, § 1, 9-20-05; Ord. No. 2009-602, § 1, 10-20-09; Ord. No. 2013-571, § 1, 9-17-13; Ord. No. 2014-023, § 1, 1-7-14; Ord. No. 2016-437, § 1, 7-5-16; Ord. No. 2021-086, § 1, 2-2-21; Ord. No. 2025-813, § 1, 11-4-25)
Ask a question about Waco law
Corpus searches the Waco sections it holds and shows the ones that match, with their citations. Free, no sign-in.