15-41-4: SITE DESIGN STANDARDS:
New construction of a building on a portion of a lot or new construction on a cleared site, reuse of an existing building, including change to the parking area or expansion of an existing building and parking area are to be developed according to the following requirements: A. RBL And Setbacks For New Construction In NC-1 And NC-2 Zones: The street facing facade shall have a minimum of sixty percent (60%) of the building built to the required build to line (RBL). Parking areas shall be set back from the property lines based on the following minimum setbacks. Interior side yard setbacks shall be the same width for both interior side yards. | Building | Parking Facing a street | 0' RBL | 20' setback Interior side | 0' setback except when next to residential use then 10' | 10' setback unless has shared access then 0' Rear | 0' setback except when next to residential use then 10' | 5' setback [image omitted; see the official code] B. RBL And Setbacks For Existing Buildings, Additions, Parking Lots And Vehicle Accessways: 1. Existing buildings that are being used or proposed for reuse are exempt from the setbacks and RBL requirements for new construction. 2. Additions to an existing building shall comply with setback requirements for new construction listed above. Expansions of the existing building to the street face of the building shall meet the RBL requirement distance as close as possible given the total size of the proposed addition. The longest axis of the building addition shall be directed toward the street property line. This provision is met when the expansion is toward the street in either direction on a corner lot development. [image omitted; see the official code] 3. When either an expansion or reuse of the building occurs, an existing on site parking lot which does not meet the minimum parking setback requirements for new construction shall comply with the required setback and landscaping of unused access areas and parking lot landscaping requirements of this chapter. The planning commission may approve a lesser landscaped setback if it is determined the landscaping would eliminate required parking because it removes the parking or the backup area needed to make the parking function. In these situations the planning commission may require a maximum three foot (3') tall screen brick wall or a hedge to be installed in lieu of the full landscaped setback. C. Maximum Building Height: 1. NC-1 zone: Twenty feet (20'). 2. NC-2 zone: Thirty five feet (35'). D. Minimum Lot Area: There is no minimum lot area requirement. Appropriate lot size is based on the ability to meet all development requirements of this chapter to determine if the lot is of sufficient size for the proposed use. E. Vehicle Access: 1. One vehicle access into or out of any single lot development shall be permitted per street frontage. A second access on a street frontage for a lot shall be allowed if there is a shared access with an adjoining NC zoned property or if the lot has sufficient frontage for a second accessway separated by at least two hundred fifty feet (250') from the first accessway. 2. The driveway width shall be a minimum of twenty four feet (24') wide for two-way access and a maximum of twenty eight feet (28') wide. A one-way driveway shall be a minimum of fourteen feet (14') wide and a maximum of eighteen feet (18') wide. 3. Adjacent lots in an NC zone shall have a shared access when possible. The developer must contact the adjacent property owner closest to the proposed driveway and supply a letter that the owner is willing or not willing to enter into a shared access easement. If the adjacent owner is not willing to share access their reason should be stated on the letter. If a shared accessway occurs it shall be secured by a shared reciprocal access easement recorded on both properties which share the access prior to issuing a building permit. 4. If parking lots do not share an access, the accessway shall be set back a minimum of ten feet (10') from any side or rear yard property line extended to the street and shall not be closer than fifty feet (50') to any street corner. F. Parking Lot Locations: 1. Parking areas shall be located to the side or rear of the building. 2. For the purpose of this regulation the street facing facade is considered the front of the building and parking cannot be located between the front of the building and the street. Existing parking lots that are between the front of the building and the street are allowed to continue after reuse of the building or expansion of the building provided the landscape setbacks are installed according to subsection B3 of this section and the parking lot design standards of subsection G of this section are met. [image omitted; see the official code] G. Parking Lot Designs: 1. Parking areas shall have concrete edging installed to separate landscaping from parking areas. When landscaping is required it shall not be placed over asphalt or concrete. Whenever a landscaped island under this provision is required it shall be a minimum width of nine feet (9') and shall extend the length of the parking stalls it abuts. Landscaped islands shall be required for each of the following conditions: a. The end of each row of stalls. b. One island shall be placed to divide a longer row of stalls so there are no more than twenty (20) stalls between islands. c. To define parking lot entrances. [image omitted; see the official code] 2. When landscaped islands are required, a minimum of one deciduous tree shall be planted for each eighteen foot (18') length of island. This tree requirement is in addition to the number of trees required on the remainder of the lot. The surface of the islands shall be planted and maintained with low water demand plants. The plants shall be of such size and spacing that they shall cover the surface of the island within three (3) years. Plantings shall be maintained at a height not to exceed three feet (3') except for the trees which shall have a clear area up to six feet (6') above the parking lot surface. 3. A minimum five foot (5') wide walkway shall be installed which connects the parking lot to the main entrance of the building and also leads to the public sidewalk parallel to the street. This walk shall be of a different material from the parking lot surface so it is easily identified and separates pedestrian traffic routes from the vehicle movement patterns. 4. Sites formerly used as convenience stores or service stations where fueling pumps have been removed or are no longer in service shall landscape these areas which are no longer needed for required access or parking in order to become more compatible with the residential character of the surrounding area. Notwithstanding the provisions that specify when the required landscape setback is to be installed, the specific locations of 675 N. Monroe, 1390 E. 9th Street, 2605 Monroe and 2975-2985 Lincoln shall submit a landscape development plan to the planning commission by June 1, 2009, showing how the total paved area on the site will be reduced to comply with a modified parking requirement as provided in this paragraph, access areas and limited driveway approaches according to the requirements of this chapter. Based on the scale of the improvements, the planning commission shall establish a time frame from one to a maximum of three (3) years for the landscaping improvements to be completed and excess paving removed. The modified parking requirement to be met is based on the use of the property on January 13, 2009, and allows maximum parking of one stall per two hundred (200) square feet for a convenience store that is being reused, one stall per three hundred (300) square feet for a general retail use and one stall per one hundred (100) square feet for fast food use. H. Lighting: 1. The maximum height for freestanding parking lot lighting shall be fifteen feet (15') in the NC-1 zone and twenty feet (20') in the NC-2 zone. Lighting standards shall be installed along the street frontage of the property on the private property side at a spacing of ninety feet (90') on center. 2. All parking lot and security light sources shall direct the light downwards through the means of shields or light fixture designs. The maximum light angle from the light source shall be sixty degrees (60°) from vertical. 3. Notwithstanding the maximum light angle, no direct lighting shall be permitted to occur on adjacent residential properties. Direct view of the light source and the light they produce from the rear or side yard of residential properties including light from signs is prohibited. 4. A minimum of fifty percent (50%) of the parking lot lighting shall be extinguished one hour after the close of business but no later than ten o'clock (10:00) P.M. Security lighting shall also meet the standards of this section. I. Mechanical And Service Equipment: 1. All ground mounted equipment, including transformers and dumpsters, shall be located at the side or rear yard of the site and screened from the public view and adjacent property owners by use of a minimum six foot (6') tall masonry wall. a. Walls must be compatible in design and materials to the buildings within the development in regards to textures, colors and materials. b. Dumpsters should be confined to portions of the site least visible from public view. [image omitted; see the official code] 2. Roof mounted mechanical equipment, including satellite dishes with a diameter of four feet (4') or larger and antennas, shall be fully screened from public view and adjacent property owners by means of a penthouse structure or behind parapet walls. Screening materials should be compatible with the materials, textures, and colors of the building. Screening designs should be architecturally integrated with the building top and maintain balance in the building design. J. Fencing: 1. No fencing shall be allowed in the front parking setback area in either the NC-1 or NC-2 zone. A masonry wall no taller than three feet (3') in height may be allowed in the front setback area provided the wall has the same design characteristics of color, texture and materials as found on the main building on the site where the wall is constructed. 2. Screening fences or walls are required along the side or rear yard areas when an NC zone is next to a residential zone. The fence or freestanding wall shall be a minimum of six feet (6') and a maximum of seven feet (7') in height. The wall of the building may act as the required screening wall provided no service or delivery doors are on that wall face and there is no parking or access between the wall of the building and the property line. 3. Chainlink with vision slats or other covering material shall not be considered as appropriate screening fence material in the NC-1 and NC-2 zones. K. Required Parking: The number of on site parking stalls for NC zones shall be limited to a maximum number of stalls allowed in order to promote and retain the neighborhood character of the NC zones. On site parking shall comply with the parking design standards of chapters 4 and 12 of this title with the exception of design standards listed in this chapter and the number of required parking stalls as required in this section. The amount of parking allowed is based on the total building square footage of all buildings on the site (not including residential uses). Building expansion or new construction shall create the requirement for the site to come into compliance with the required maximum parking on the property. | | Maximum Number OfParking Stalls Permitted Commercial floor area: | | | 3,000 or less square feet | | No on site parking required except if parking already exists then 1 stall per 400 square feet of building maximum number of stalls | 3,001 to 5,000 square feet | | 1 stall per 400 square feet maximum number of stalls | 5,001 to 10,000 square feet | | Limited to 12 stalls plus 1 stall per 450 square feet of building over 5,000 square feet | 10,001 and greater | | Limited to 23 stalls plus 1 stall per 500 square feet of building over 10,000 square feet. The planning commission may approve additional parking up to a ratio of not less than 1 stall per 350 square feet of building provided that enhanced neighborhood amenities along the perimeter of the project are installed as part of the development such as sheltered mass transit stops, theme streetscape lighting, or public plaza. The number of additional parking stalls allowed will be based on the equivalent value of additional parking stalls to the value of the amenity proposed to be provided Residential | | 1 stall per dwelling unit minimum with a maximum of 2 stalls per unit (Ord. 2009-17, 1-13-2009; amd. Ord. 2009-60, 9-8-2009)
Ask a question about Ogden law
Corpus searches the Ogden sections it holds and shows the ones that match, with their citations. Free, no sign-in.