§ 8-7-5 — FUELING, FLAMMABLE FLUIDS, AND SAFETY
City Code of Ogden City, Utah (2026 S-26: code current through Ord. 2026-7, passed May 5, 2026) · Ogden City Municipal Code § 8-7-5
Corpus is an independent public-information project, not the official City of Ogden website. Stable reference: corpuslaw.us/code/cd93f0ac-ae71-40db-a596-03d1ce401a00
8-7-5: FUELING, FLAMMABLE FLUIDS, AND SAFETY:
A. Fuel Safety: All transportation, storage and other handling of aircraft and vehicle fuel within the airpark shall comply with the current fire code, as adopted by Title16, Chapter 2, or its successor provisions, the National Fire Protection Association’s codes and standards, as amended, FAA advisory circular 150/5230.4, as amended, all requirements of these regulations, and all other applicable laws. B. Aircraft Fueling: All aircraft fueling shall be performed outdoors and no closer than 25 feet to a structure. Aircraft fueling in the airpark may only be conducted by: 1) an authorized FBO; or 2) an airpark aviation operator fueling its airpark based aircraft at its based location and pursuant to a city issued self-fueling permit. Fueling of nonbased aircraft or aircraft not at its based location by other than an authorized FBO is prohibited. C. Removal of Gas, Oil, Grease, Aircraft Washing Effluent, Etc.: In the event of spillage or dripping of gasoline, oil, grease, aircraft washing effluent or any material which may be unsightly or detrimental to an airpark taxilane safety area, the same shall be removed immediately. The responsibility for the immediate removal of such gasoline, oil, grease, aircraft washing effluent or other material shall be assumed by the operator or owner of the equipment causing the same or the property owner responsible for the deposit. In the event of such spillage, and the failure of the operator or owner to restore the area to its original safe and environmentally sound status, the city may clean up any material unlawfully spilled, placed or otherwise deposited in an airpark taxilane safety area and may charge the responsible person(s) for the cost of the cleanup, any required environmental remediation, and expenses incurred by, or fines or damages imposed on, the city as result thereof. Such an event may constitute grounds for denying access to the airport in accordance with the provisions of this title, as amended. D. Fire Extinguishers: 1. All airpark aviation operators shall supply and maintain such adequate and readily accessible fire extinguishers as may be required by the city or fire department. Each fire extinguisher shall carry a suitable tag showing the date of most recent inspection. 2. At least two fire extinguishers, each having a rating of at least 20-BC, shall be available for use in connection with the aircraft fuel handling operations. E. Unauthorized Fuel Possession and Storage: Except as expressly permitted by these regulations, no person shall possess aircraft fuel in the airpark. F. Fuel Facility Permit: Any airpark aviation operator shall meet, and at all times maintain compliance with, the following conditions before the city will issue a self-fueling permit and consider any such operator in good standing: 1. The fuel storage area from which the aircraft is to be fueled shall be on the same building site as the based location of the based aircraft owned or leased by the operator, except in the case of an authorized FBO. 2. The fuel storage area shall be equipped with a fuel flowage meter of a type approved by the city. 3. If the hangar facility at which the fuel storage area is located is approved to conduct hangar/shade leasing and fuel is dispensed into based aircraft, the fuel flowage meter shall be regularly calibrated and copies of such test results regularly provided to the city upon request; and 4. The identification number (“N” number) of the aircraft based in the airpark and applying for an airpark access permit shall be affixed to the fuel storage area in a form and manner approved by the city as well as displayed in a location that is visible at the pump, or the identification numbers shall be reported monthly to the airport in a written form and manner acceptable to the city. 5. Aircraft fuel dispensed from an approved airpark fuel storage area shall only be supplied an airpark based aircraft at its based location pursuant to a self-fueling permit, except fueling performed by an authorized FBO. No retail aircraft fuel sales shall take place in the airpark except those provided by an authorized FBO. G. Movable Aircraft Fuel Storage Tanks: Unless otherwise approved by the airport director and city fire marshal, movable aircraft fuel storage tanks are prohibited in the airpark except for: 1. Aircraft fueling/defueling trucks and trailers constructed, operated and maintained in all respects as required by law. Such aircraft fueling/defueling trucks and trailers shall be operated in the airpark solely by an authorized FBO, or in the case of defueling equipment only, by an aircraft accessory services operator, aircraft airframe and engine repair operator or technical specialist. 2. Permanent fuel tanks in an operable aircraft. 3. Tanks not exceeding one gallon capacity used solely for sampling and testing fuel, engines and fuel handling apparatus. 4. No more than one tank with a capacity of not more than 55 gallons used by a person to fuel his own aircraft pursuant to a self-fueling permit. Said tank must be stored outside and no closer than 50 feet to any structure. 5. Tanks in transit for the purpose of lawfully transporting fuel for immediate dispensing into a fuel storage area permitted by the city. H. Aircraft Owner Self-Fueling: Except as may be prohibited by other provisions of these regulations and any other applicable law, airpark aviation operators who desire to self-fuel their airpark based aircraft, shall apply for and receive a self-fueling permit from the city prior to conducting self-fueling. I. Inspection of Fuel Facilities and Records, Meter Readings and Reporting: 1. The city and its officials, representatives, and agents shall have a continuous right of access onto private property in the airpark for the purpose of inspecting fuel facilities and equipment. Fuel storage and dispensing records shall be regularly subject to inspection by the city upon reasonable notice. Such inspection may include, but not be limited to, taking meter readings, reviewing and inspecting fuel storage records, fueling apparatus, training records, emergency equipment, and any and all material for safe fuel handling. 2. Airpark aviation operators who conduct self-fueling shall submit to the airport in a manner acceptable to the city not later than the tenth day of the following month a written monthly fuel inventory reconciliation report. The reconciliation report shall include: a. The type and amount of fuel dispensed into all aircraft, fixed wing and helicopters. b. The type and amount of fuel received, spilled, leaked, defueled from aircraft or otherwise accounted for. 3. If required by state law, airpark aviation operators shall submit annual tightness testing reports to the city fire department no later than 20 calendar days after such testing is performed. J. General Insurance Requirements: Any person owning, operating or otherwise responsible for an airpark aircraft fuel storage facility shall at all times comply with federal, state and local law concerning insurance, liability and financial responsibility for fuel storage facilities including, but not limited to, 49 USC 100 1ff and 40 CFR 280 et seq. (Ord. 2005-45, 7-19-2005; amd. Ord. 2011-39, 6-28-2011; Ord. 2025-43, 12-16-2025)
Ask a question about Ogden law
Corpus searches the Ogden sections it holds and shows the ones that match, with their citations. Free, no sign-in.