For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9-2-5 — WATER MAIN PIPES AND SERVICE LATERALS; STANDARDS

City Code of Ogden City, Utah (2026 S-26: code current through Ord. 2026-7, passed May 5, 2026) · Ogden City Municipal Code § 9-2-5

Corpus is an independent public-information project, not the official City of Ogden website. Stable reference: corpuslaw.us/code/056dbf15-980f-481c-a8fb-408c0b2a760e

9-2-5: WATER MAIN PIPES AND SERVICE LATERALS; STANDARDS:

The following standards shall be applicable to the installation, repairs or replacement of all main water pipes and service laterals: A. Installation, Repairs Or Replacement: All main water pipes three inches (3") and larger shall be of ductile iron pipe, class 51. All service laterals two inches (2") and smaller shall be of type K copper from the connection at the main to the water meter or control valve. Service laterals three inches (3") and larger shall be of ductile iron, class 51, except in certain or private developments under the following conditions: 1. Ownership of all water pipes and service laterals extending from the owner's side of the meter, together with all maintenance and repair responsibilities, shall be retained by the developer or association governing the operation and maintenance of the development; 2. Main water pipes and service laterals located solely within the private development that feed fire hydrants shall be either ductile iron pipe, class 51, or C-19900 PVC pipe, class 150, D.R. 18 or D.R. 14; 3. The private development shall be supplied by a single service lateral and a single master meter. If there are fire hydrants located within the development, the master meter shall be a detector type to allow full flow of water for firefighting purposes; 4. Service laterals supplying the development sizes three inches (3") and larger shall be of ductile iron, class 51, from the connection at the main to the water meter; 5. All water pipe regulated by this chapter shall be installed according to specifications and requirements of the public services department; 6. "Main water pipes" are defined as those water pipes that provide water service to customer service connections and fire hydrant service connections by means of service laterals; 7. "Service laterals" are defined as those water pipes that are connected to the main water pipe and provide customer service to a fire hydrant or a single customer that consists of one or more buildings or dwellings. B. Grade And Class: Both copper and ductile iron class 51 or higher shall be of a grade and class sufficient to stand working pressures of one hundred fifty (150) pounds per square inch. The pipe shall be laid not less than forty eight inches (48") below the surface of the ground. In running the service pipe underneath a curb and gutter, the forty eight inches (48") of cover shall be mandatory. C. Copper; Placement: In placing copper service pipe, the pipe at the connection to the corporation stop at the main must bend in "S" form approved by the water manager to allow for movement of pipe and/or to prevent rupture due to settlement. Where it is necessary for copper pipe to be connected to copper pipe, the connection must be made with a forty five degree (45°) flared three (3) part union or a compression coupling. No union of this type shall be permitted in any one inch (1") copper service line extending less than one hundred feet (100') in length, or in any larger copper service extending less than forty feet (40') in length. D. Ductile Iron; Placement: In placing ductile iron service pipe, a compression type coupling with metal tipped gaskets shall be placed in the line not more than thirty six inches (36") or less than twelve inches (12") from the face of the tapping valve. Sizes larger than three inches (3") shall be connected directly to the tapping valve. E. Stop And Drain Valves: A stop and drain valve must be relocated inside the foundation wall of every building connected to a service lateral. If it is necessary for the utility to shut off the service lateral at the curb for repairs within the building because there is not a shutoff valve, a reasonable charge as approved by the water manager will be made for the service and the line will not be turned on again until a shutoff valve inside the building wall is in operation. F. Angle Valves: When service pipe is run only at a point back of the curb for future use, meter box, ring and cover and an angle valve shall be placed not further than twelve inches (12") from the inside face of the curb. G. Fixtures: Fixtures for general use must not be attached to elevator, standpipe or motor connections, but must be entirely separate from other connections. Service pipes to houses which are built out to the street line and which include an area extending under the sidewalk must be run down the outside of the curb and under the wall around such area so as to be securely protected from frost. The stop and drain valve shall be located inside the building wall. H. Inspections: All runs of pipe outside of buildings, whether of original or extension work, and all disconnected services must be inspected and approved by the city before being covered up. Where a tap is to be made, pipes must be connected up on the trench ready for immediate attachment to the main, so that the pipes may be properly tested while connected. I. Nonconforming Pipe: 1. In putting in a service, no plumber will be permitted to make use of pipe previously run to curb which does not conform to the rules existing at the time such service is to be used. Before making such connections, the existing pipe must first be approved by the utility. If the existing pipe is not approved, the owner will be required to have it changed at his expense and if an entirely new service shall be put in, the old one shall be disconnected at the expense of the owner before the water is turned on to the new service. 2. This rule shall also apply to premises for which plumbing has already been installed, and if the plumbing does not conform with existing rules it must be overhauled at the owner's expense and approved by the utility before it is connected with the main. J. Existing Services; Disconnection: In all cases where one or more service pipes are connected, the main and new service is installed to replace the existing service or services, the existing service or services shall be disconnected at the main at the expense of the owner or consumer, before tap is made for the new service. K. Approval: All work upon and alterations or extension of water pipes and size of pipes shall be approved by the utility. (1979 Code § 14.10.060; amd. Ord. 86-49, 12-11-1986; 1999 Code; Ord. 2004-39, 6-15-2004, eff. 7-1-2004)

Ask a question about Ogden law

Corpus searches the Ogden sections it holds and shows the ones that match, with their citations. Free, no sign-in.