§ 9-4-2 — DEFINITIONS

City Code of Ogden City, Utah (2026 S-26: code current through Ord. 2026-7, passed May 5, 2026) · Ogden City Municipal Code § 9-4-2

Corpus is an independent public-information project, not the official City of Ogden website. Stable reference: corpuslaw.us/code/d7839599-9d07-40a4-8766-3477662b5f70

9-4-2: DEFINITIONS:

As used in this chapter: APPROVED: Having an approved application as provided by this chapter. APPROVED BACKFLOW PREVENTION ASSEMBLY: A testable backflow preventer authorized by the water director for its intended use that is installed in compliance with applicable plumbing codes. Backflow preventers must be included in the currently approved backflow prevention assemblies list developed by the University of Southern California, Foundation for Cross-Connection Control and Hydraulic Research, or other testing laboratories using equivalent testing methods. Such assemblies may include the following types: A. Double Check Valve Assembly (DC): An assembly consisting of two independently acting, approved check valves, including tightly closing resilient seated shut-off valves located at each end of the assembly and fitted with properly located resilient seated test ports. This assembly is approved for use against non-health hazards (i.e., pollutants). B. Double Check Detector Assembly (DCDA): A specially designed assembly consisting of a line-size approved double check valve assembly with a bypass containing a specific water meter and an approved double check valve assembly. The meter shall register accurately for rates of flow up to two Gallons Per Minute (GPM) and shall show a registration for all rates of flow. This assembly shall only be used to protect against a non-health hazard (i.e., pollutant). This DCDA is primarily used on fire sprinkler systems. C. Pressure Vacuum Breaker (PVB): An assembly containing an independently operating, internally loaded check and an independently operating loaded air inlet valve located on the discharge side of the check valve. The assembly is equipped with properly located resilient seated test ports and tightly closing resilient seated shut off valves attached at each end of the assembly. This assembly is designed to protect against a non-health hazard (i.e., pollutant) or a health hazard (i.e., contaminant) under a back siphonage condition only. D. Reduced Pressure Principle Assembly (RP): An assembly containing two independently acting approved check valves together with a hydraulicly operating, mechanically independent differential relief valve located between the check valves and situated below the first check valve. The unit shall include properly located resilient seated test ports and tightly closing resiliently seated shut off valves at each end of the assembly. This assembly is designed to protect against a non-health hazard (i.e., pollutant) or a health hazard (i.e., contaminant). This assembly shall not be used for backflow protection of sewage or reclaimed water. E. Spill Resistant Vacuum Breaker (SVB): Is the same as a PVB in application. However, this assembly is designed to minimize the discharge of water from the air inlet port. This enables the end user to use the SVB in situations where it would be undesirable to have water discharged into the surrounding areas. APPROVED BACKFLOW PREVENTION DEVICE: A non-testable backflow preventer authorized by the water director for its intended use that is installed in compliance with applicable plumbing codes. Such devices may include the following types: A. Air Gap: A device that creates physical separation between the free-flowing discharge end of a potable water supply pipeline and an open or non-pressure receiving vessel. An air gap shall be at least twice the diameter of the supply pipe measured vertically above the overflow rim of the receiving vessel; in no case less than one inch. B. Atmospheric Vacuum Breaker (AVB): A device consisting of an air inlet valve, a check seat and an air inlet port(s). Water flow into the AVB causes the air inlet valve to close. This allows water to flow through the assembly, and when the water flow stops, the air inlet valve drops down to the check valve seat. Additionally, as the air inlet opens, it allows air into the body of the assembly through the air inlet port, which compensates for any vacuum and separates the downstream non-potable water from the upstream potable water. This assembly is effective when used in the proper application. C. Dual Check Valve: A device consisting of two spring-loaded, independently acting check valves. Dual check valves may be used for back siphonage or back pressure. However, dual check valves shall only be used for pollutants/non health hazards and are considered secondary protection. AUXILIARY WATER SUPPLY: Water supply on or available to the premises other than the city's public potable water supply. These auxiliary waters may include used waters, industrial waters, or water from another purveyor's public potable water supply or any natural source(s) such as a well, spring, river, stream, irrigation canal, or secondary water system, etc. when the waters are polluted, contaminated, or objectionable and constitute an unacceptable water source over which the city does not have sanitary control. BACKFLOW: The undesirable reversal of flow of water or other liquids, mixtures, or substances into the distributing pipes of a potable water supply system from any source or sources other than its intended source. Backflow occurs due to backpressure or back siphonage. BACK PRESSURE: Any elevation of pressure in the downstream piping system (by pump, elevation of piping, steam pressure, air pressure, etc.) above the supply pressure at the point of consideration, which would cause or tend to cause a reversal of the intended direction of flow. BACK SIPHONAGE: A form of backflow due to a reduction in the system pressure, which causes a sub-atmospheric pressure to exist in the water system. CERTIFIED BACKFLOW TESTER: An individual that has successfully completed a Utah Division of Drinking Water approved backflow certification course with a written and practical examination and has maintained this certification in accordance with Utah Administrative Rule R309-305-8. CONSUMER: The owner or operator responsible for the purchase of water service from Ogden City Water system and who is responsible for the internal plumbing of the private water system to which Ogden City Water provides water service. CONTAINMENT: The installation of an approved backflow prevention assembly or backflow prevention device to prevent backflow. Containment occurs downstream of water meters and prior to any tees or connections. Containment occurs to protect the water purveyor's water system from the consumer's private plumbing system as required by plumbing code. CROSS CONNECTION: Any actual or potential connection between a potable water system and any other source or system through which it is possible to introduce into the public drinking water system pollutants or contaminants from sources such as used water, industrial fluid, gas, or substances other than the intended potable water. DEGREE OF HAZARD: A determination of either a pollutant (non-health hazard) or contaminant (health hazard) derived from the assessment of the materials used within the consumer's private plumbing system, which may enter the city's water distribution system through an actual cross-connection. HAZARD ASSESSMENT: The process by which the water director will accompany the owner or agent of the owner during an on-site survey to determine water usage degrees of hazard wherein the identification of a cross-connection may occur and require installation of an approved backflow prevention assembly or backflow prevention device. HEALTH HAZARD: Any contaminant that shall impair the quality of water, in such a way as to create an actual hazard to the public health through poisoning, the spread of disease, etc. ISOLATION: The installation of an approved backflow prevention assembly or backflow prevention device within the water consumer's private plumbing system to prevent backflow at each point of cross-connection or system outlet as required by the plumbing code. NON-HEALTH HAZARD/POLLUTANT: An impairment of the quality of the water to a degree which does not create a hazard to public health, but adversely and unreasonably affects the aesthetic qualities of potable water for domestic use. NON-POTABLE WATER: Water which is not safe for human consumption or is of questionable quality. PLUMBING CODE: The currently adopted Utah State plumbing codes. POTABLE WATER or DRINKING WATER: Comes from surface water and groundwater sources. This water is treated to levels that meet state and federal standards for consumption. USED WATER: Any water supplied by a water purveyor from a public potable water distribution system to a consumer's private plumbing system after it has passed through the point of delivery and is no longer under the sanitary control of the water purveyor. WATER DIRECTOR: The water director or water director's designee. WATER SERVICE CONNECTION: The terminal end of a service connection from the city's water distribution system, i.e., where the water purveyor loses sanitary control over the water at its point of delivery to the consumer's private plumbing system. When a meter is installed at the end of the public water supplier's service connection, then the service connection shall mean the downstream consumer's side of the meter and where used water is then defined at the point of delivery. "Water service connection" also includes water service connections from a fire hydrant and all other temporary or emergency water service connections from the public potable water system. (Ord. 2025-32, 10-21-2025)

Ask a question about Ogden law

Corpus searches the Ogden sections it holds and shows the ones that match, with their citations. Free, no sign-in.