§ 11-11-130 — Piping system

Code of the City of Alexandria, Virginia (Supp. No. 156: codified through Ordinance No. 5616, adopted January 24, 2026) · Alexandria City Code § 11-11-130

Corpus is an independent public-information project, not the official City of Alexandria website. Stable reference: corpuslaw.us/code/96886b13-f35f-4b4d-8328-c71f564e64d1

Sec. 11-11-130 - Piping system.

(a) The piping system for interactive water feature facilities shall be composed of NSF listed materials or their equivalent designed for the following operations: (1) circulating water to the interactive water feature; (2) collecting and re-circulating the water through the treatment equipment; (3) backwashing or washing each filter to waste; and (4) draining the system. (b) There shall be no direct connections between the recirculation system and the sewer or potable water supply. (c) The system shall have a means of discharging filter backwash or other water to waste as follows: (1) Waste from backwashing or draining shall be discharged in a manner approved by the director. When only a sanitary sewer is available, the rate of discharge is subject to the approval of the appropriate authority for sanitary sewers and treatment facilities. (2) An air gap to prevent a cross-connection between waste discharge piping and recirculation piping shall be provided. (3) Discharge receptor and piping of sufficient size to accept backwash water and prevent backflooding. (4) A sight glass in the backwash discharge line in a readily observable location. (5) In the event the backwash waste pipe will not accommodate the backwash flow, the design and installation of a holding tank shall be required. The holding tank shall be sized to contain 110 percent of the volume of water required to adequately clean the filter(s) at the backwash flow rate and length of time specified by the filter manufacturer. (d) The piping system shall be securely anchored, supported or braced, unless inherently self-supporting. Visible piping shall be marked with permanent tags, labels or markings to clearly identify the direction of flow and shall be color coded as follows: (1) freshwater blue (to check valve). (2) backwash black. (3) influent yellow. (4) effluent white. (e) All piping shall be designed to minimize friction losses and to carry the required quantity of water at a velocity not to exceed eight feet per second for copper discharge piping, and 10 feet per second for discharge piping other than copper. Suction velocity for all piping shall not exceed six feet per second. Pipe suction velocity may also be limited by the maximum flow rate specified by the manufacturer of the suction outlet covers installed. (f) All piping and appurtenances included in the recirculation and filtration system shall be inspected and approved by the director prior to covering. All piping shall be tested at the time of inspection to at least 25 psi of pressure. All subsurface piping shall be imbedded in and covered with sand or an approved equivalent. (g) All valves shall be clearly identified with permanent markings or tags which are referenced by a water recirculation system operation manual and/or placard. (Ord. No. 4649, 3/13/10, Sec. 1; Ord. No. 5010, 5/14/16, Sec. 1)

Ask a question about Alexandria law

Corpus searches the Alexandria sections it holds and shows the ones that match, with their citations. Free, no sign-in.