§ 5-6-62 — Specifications
Code of the City of Alexandria, Virginia (Supp. No. 156: codified through Ordinance No. 5616, adopted January 24, 2026) · Alexandria City Code § 5-6-62
Corpus is an independent public-information project, not the official City of Alexandria website. Stable reference: corpuslaw.us/code/866d5065-f622-4627-ae6a-6165fd2daa73
Sec. 5-6-62 - Specifications.
(a) Generally. All septic tank systems installed or repaired in the city shall consist of sewer line from building to tank, septic tank, distribution box and drain tile disposal field. The sewer line shall be of cast-iron soil pipe, unless otherwise specified by the plumbing inspector. The entire system shall be built in accordance with the plans and specifications shown on the permit required. (b) Excavations. All excavations and trenches shall be of sufficient dimensions to permit sewers, tanks and other structures of the size shown, specified to be properly placed therein, according to the plans and specifications as required by this regulation, and to permit the removal of any obstructing material within the disposal field. (c) Re-excavations and the filling and refilling of trenches. (1) Where unsuitable foundation is encountered at the depth of any excavation shown on the drawing or specified by the director of public health, further excavation and refilling the excavated spots with such foundation material as may be directed by film, is hereby required. (2) A representative of the health department shall inspect septic tank construction after completion and before any part of the system shall be covered. Septic tank systems shall be back-filled immediately after inspection and approval by the director of public health and care shall be taken not to disturb the pipe, grades, joints or alignment by the backfilling, or otherwise. (d) Pipes and jointing materials; size and types of house sewer. (1) The house sewer for individual homes shall be constructed of four inch or larger cast-iron pipe or equivalent. (2) All house sewer pipes shall be laid complete with all jointing materials. All house sewer cast-iron pipe shall be jointed with lead and oakum or similar jointing material, and shall be approved by the plumbing inspector. (3) All house sewer pipe shall be laid accurately and shall have a grade of not less than one-fourth (¼) of an inch to the foot, or as otherwise specified by the director of public health, and approximately 30 inches from the outside of the house there shall be a standard cast-iron cleanout tie with screw cover, and all right angle bends in the house sewer shall be made with long sweep soil pipe ells. Where septic tanks are located more than 35 feet from the above cleanout, then additional cleanouts are to be provided. (e) Location, design, liquid capacity and material required in septic tank disposal systems. (1) Location and installation of the sewage disposal system and each part thereof shall be such that, with reasonable maintenance, it will function in a sanitary manner and will not create a nuisance nor endanger the safety of any domestic water supply. In determining a suitable location for the system consideration shall be given to the size and shape of the lot, slope of natural and finished grade, depth of ground water table, proximity to existing or future water supplies, and possible expansion of the system. a. No part of the system shall be located so that it is nearer to any water supply than 50 feet, or so that surface drainage from its location may reach any domestic water supply. b. The lot size shall be sufficient to permit proper location, installation and operation. The disposal field shall be located at least 10 feet from property line. c. Installations in low swampy area or areas with a high water table or which may be subject to flooding are prohibited. (2) Type of system shall be determined on a basis of location permeability and ground water level. a. The system shall be designed to receive all sanitary sewage from the dwelling. b. Basement floors, footings or roof drainage shall not enter any part of the septic tank system. (3) Design of the septic tank shall be rectangular in shape and the length shall not be less than twice nor more than three times the width. The liquid depth shall be not less than four feet and the freeboard or airspace shall not be less than one foot. (4) Liquid capacity of all septic tanks shall be based upon the number of bedrooms contemplated in the building served and shall conform to Table I, herein shown. TABLE I. CAPACITY OF SEPTIC TANK Potential | Minimum | Minimum Dimensions of Septic Capacity of Home No. of Bedrooms | Capacity of Septic Tanks Gallons | A Length | B Width | C Air Space | D Liquid Depth 3 or less | 720 | 7′0″ | 3′6″ | 1′0″ | 4′0″ 4 | 1000 | 8′0″ | 4′0″ | 1′0″ | 4′0″ 5 | 1250 | 9′0″ | 4′6″ | 1′0″ | 4′3″ 6 | 1480 | 9′6″ | 4′8″ | 1′3″ | 4′6″ 7 | 1720 | 10′0″ | 5′0″ | 1′3″ | 4′8″ (5) Construction of the septic tank shall be such as to assure its being watertight and prevent the entrance of rain water or surface drainage. a. The tank shall be constructed of sound and durable material not subject to excessive corrosion or decay. b. Adequate access to each compartment of the tank for inspection and sludge removal, shall be provided by a manhole or removable cover. 1. Where the top of the tank is located more than 18 inches below the surface of the ground, manholes shall be built up to within 12 to 18 inches of the surface. c. Inlet and outlet connections shall be submerged or baffled to assure the least possible disturbances in the tank. 1. The inlet pipe or baffle shall extend approximately six inches above the water surface and the outlet shall extend approximately two feet below and six inches above the water surface. 2. Venting of the tank shall be provided through the inlet and main building stack and shall be approved by the plumbing inspector. The outlet shall be similarly vented to provide proper ventilation of the disposal field or seepage pits back into the septic tank and thence through the main building stack. d. Septic tanks shall be poured-in-place concrete, or precast concrete, or brick wall, or cinder block wall, or properly coated metal. 1. Concrete septic tanks, poured in place, shall be poured with a standard concrete mixture of 1-2-3 or 1-24 mix. Where the excavation is subject to caving, or where the water table is objectionably high, outside forms and pumping will be required in order to assure a water-tight tank. The walls, top and bottom of the tank are to be not less than four feet thick, as shown on plans; top and manhole cover to be reinforced with reinforcing steel, as shown on plans. 2.i. Precast concrete tanks shall be of a design and size as stated in specifications submitted in accordance with section 5-6-61 of this code, and made with a standard 1-2-3 mixture. The walls shall not be less than two and one-fourth (2¼) inches in thickness, reinforced with No. 9 steel placed as shown in specifications submitted in accordance with section 5-6-61 of this code. ii. The precast tank may be made in two sections or more with a horizontal half lap joint, cement grounded. The bottom or top and a portion of the side walls shall be poured monolithically. 3. Where metal septic tanks are used, they are to be of the same design and with the same fittings as required for concrete tanks, provided they are constructed of a material of sufficient thickness and properly coated to prevent rusting. (f) Subsurface disposal field. (1) Location of the disposal field should be in an unobstructed and unshaded area, and the distances given shall be the minimum which the disposal field can be located from the following: ;$; a. Any water supply (except as noted below) .....50 feet b. Streams .....25 feet c. Dwellings .....10 feet d. Large trees .....10 feet e. Property lines .....10 feet ; f. When existing wells are involved or exceptionally coarse soil formations are encountered, the 50-foot distance from any water supply shall be increased in accordance with the recommendations of the health department. (2) Distribution box of sufficient size to accommodate the necessary field lateral lines shall be constructed at the head of each disposal field. a. Each field lateral line shall be connected separately to the distribution box and shall not be subdivided. b. The invert of all outlets shall be level and the inlet invert shall be at least one inch above the outlets. (3) Minimum seepage area (total flat bottom of trenches) of the disposal field shall be determined by one of the following methods: a. Recommendation of the health department, based upon experience data, in which case requirements should be stated on a basis of square feet of absorptive area per bedroom rather than lineal feet of tile. b. Results of actual percolation tests conducted on the site of proposed disposal field. The tests shall be made by the owner and under the direct supervision of the health department and in the following manner: 1. Number of test holes. When a septic tank disposal field is to be constructed for a single dwelling unit with two bedrooms or less, a minimum of two test holes shall be used. One additional hole shall be provided for each additional bedroom to be served. When installations are planned for multiple units or buildings not used as dwellings at least one test hole shall be provided for each 400 square feet of area of the proposed disposal field site. 2. Location of test holes. The test holes shall be located on the site selected for the disposal field in a manner to be representative of the area under consideration. Tests shall not be made in filled ground unless it has been compacted for several years. All necessary surface drainage shall be completed before any percolation tests are made. 3. Preparation of test holes. The holes shall be six inches to 12 inches in size and may be either circular or square and shall be dug to the depth of the proposed disposal field trench. A fixed reference point shall be provided in each test hole to permit accurate measurements of water levels. A layer of sand or fine gravel one to two inches thick shall be placed in the bottom of each test hole before any water is placed in the hole. Earth shall be mounded around tops of holes to prevent entrance of surface water and suitable covers shall be placed over them when holes are left unattended. 4. Conducting tests. First place water in hole to depth of at least 12 inches and allow to seep away. Proceed with test by filling hole to a depth of six inches and record time required for the water to seep away. Then compute the average time required for the water level to lower one inch. If water does not disappear from hole within six hours, no further observations are necessary. 5. Determination of absorptive area from results of percolation tests. Average Time in Minutes for Water Level to Lower One Inch | Effective Absorption Area (Area in bottom of disposal trench) In Square Feet Per Bedroom or Per 100 Gal. Per Day of Estimated Water Use. 10 minutes or less | 130 11-20 minutes | 170 21-30 minutes | 210 31-40 minutes | 250 41-50 minutes | 290 51-60 minutes | 330 Over 60 minutes | Unsuitable for subsurface drainage Minimum installation shall be for a two bedroom house. (4) Construction shall be in accordance with recommendations of the health department. a. All trenches in a disposal field shall be the and length, and the following same width standards shall be required. 1. Minimum number of lines per field, two. 2. Maximum length of individual lines, 100 feet. 3. Minimum bottom width of trench, 18 inches. 4. Maximum depth of cover of tile lines, 24 inches. 5. Preferred depth of cover of tile lines, 16 inches. 6. Grade of tile lines, 2″ to 4″ per 100 ft. 7. Spacing of trenches, at least six feet apart. 8. Minimum filter material under tile, six inches. 9. Minimum filter material over tile, two inches. b. Pipe used for the lines between the septic tank and distribution box, on all lines within ten feet of dwelling, under paved areas and on all main laterals from distribution box in fields constructed on sloping ground, shall be bell and spigot type of vitrified clay or concrete with watertight joints. Pipe used under driveways or other areas subject to heavy loads shall be bell and spigot cast iron with leaded joints. The sections laid in the disposal field shall not be considered in determining the effective absorption area. c. Field tile used in the disposal field shall be not less than four inches in diameter and shall be laid with one-fourth of an inch open joints. 1. All open joints shall be protected, on top, by strips of asphalt-treated building paper at least 10 inches long and three to six inches wide. 2. All bends used in the disposal field shall have one tight joint at each end of the bend. d. Filter material shall be hard and durable, of crushed stone, gravel, slag, screened cinder or similar material having sufficient voids and shall be acceptable to the health department of the city. Such material may vary from one-fourth of an inch to three inches size. e. Grade boards, securely staked in the bottom of the trench, shall be provided for all lines except where bell and spigot pipe is used. The grade boards shall be one inch by four inches and nailed to stakes in center of the trench as shown on the plans, or grade stakes at intervals of not more than five feet. The grade boards shall be given a grade of from two inches to four inches per 100 feet. (Code 1963, Sec. 28-21)
Ask a question about Alexandria law
Corpus searches the Alexandria sections it holds and shows the ones that match, with their citations. Free, no sign-in.
