§ 6-307 — Special regulations

Code of the City of Alexandria, Virginia (Supp. No. 156: codified through Ordinance No. 5616, adopted January 24, 2026) · Alexandria Zoning Ordinance § 6-307

Corpus is an independent public-information project, not the official City of Alexandria website. Stable reference: corpuslaw.us/code/a8a4708e-59e4-45d7-bba5-28c850f3c70d

6-307 - Special regulations.

Within the boundaries of any A or AE zones in any floodplain district as shown on the flood insurance rate map, buildings or structures and their extensions and accessory buildings or structures maybe be constructed or substantially improved only in accordance with the following requirements of this section 6-300 and all other applicable provisions of law. In all identified flood hazard areas where base flood elevations have been provided in the FIS or generated by a certified professional in accordance with 6-304(A)(3) of the following provisions shall apply: (A) Residential construction. (1) New construction or substantial improvement or any residential building or structure and their extensions and accessory buildings or structures in Zones A, AE, and with detailed base flood elevations shall have the lowest floor, including basement, elevated to or above the base flood elevation plus 1-foot. (2) No building permit for the substantial improvement of an existing residential building shall be at least one foot issued unless the building has the lowest floor (including the basement) elevated to or above the base flood elevation plus 1-foot. (B) Non-residential construction. (1) New construction or substantial improvement for any commercial, industrial, or non-residential building and any extension or accessory to a non-residential building shall have the lowest floor, including basement, elevated to or above the base flood elevation plus 1-foot. (2) New construction or substantial improvement of any building designated as Flood Design Class 4 in the VA USBC shall have the lowest floor, including basement, elevated at least 1-foot above the base flood elevation or the 0.2-percent annual chance flood elevation, whichever is higher. (3) Non-residential buildings located in all A, AE, and AH zones may be dry-floodproofed in lieu of being elevated provided that all areas of the building components below the elevation corresponding to the base flood elevation plus 1-foot are watertight with walls substantially impermeable to the passage of water; and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. In no event shall any floor below the elevation corresponding to the base flood elevation plus 1-foot be used for human or animal habitation, food storage or food preparation. A registered professional engineer or architect shall certify the design and construction using the required FEMA floodproofing certification forms that the standards of this subsection are satisfied. Such certifications, including the specific elevation in relation to City Vertical Datum to which such structures are floodproofed, shall be maintained by the floodplain administrator. (4) No building permit for the substantial improvement of an existing nonresidential building shall be issued unless the building, together with attendant utility and sanitary facilities, has the lowest floor (including the basement) elevated to or above the base flood elevation plus 1-foot. Should this not be feasible, no such permit shall be issued unless the existing structure is dry-floodproofed as described in section 6-307 in all areas below the base flood elevation to the classification designated by the floodplain administrator. (5) Any mixed-use building may be considered a nonresidential building for purposes of this section 6-307 if all of the following conditions are met; otherwise, the building shall be considered a residential building: (a) No more than 20 percent of the development site is within the boundaries of any A or AE zones in any floodplain district as shown on the flood insurance rate map; (b) At least 20,000 square feet of finished floor area of the proposed mixed-use building is devoted to nonresidential use; (c) Basement areas (including below grade parking) must be located outside the boundaries of any A or AE zones in any floodplain district; and (d) All floodproofing requirements specified in this ordinance 6-300 and as specified in NFIP Technical Bulletin 3 (2021 or later) Requirements for the Design and Certification of Dry Floodproofed Non-Residential and Mixed-Use Buildings - Requirements and Certification must be met. (C) Space below the lowest floor. In zones A, AE, and AH, fully enclosed areas, of new construction or substantially improved structures, which are below the base flood elevation plus 1-foot shall: (1) Not be designed or used for human habitation, but shall be used solely for parking of vehicles, building access, or limited storage of maintenance equipment used in connection with the premises. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment (standard exterior door), or entry to the living area (stairway or elevator). (2) Be constructed entirely of flood damage-resistant materials below the base flood elevation plus 1-foot. (3) Include measures to automatically equalize hydrostatic flood forces on walls by allowing for the entry and exit of floodwaters. To meet this requirement, the openings must either be certified by a professional engineer or architect or meet the following minimum design criteria: (a) Provide a minimum of two openings on different side of each enclosed area subject to flooding. (b) The total net area of all openings must be at least one square inch for each square foot of enclosed area subject to flooding. (c) If a building has more than one enclosed area, each area must have openings to allow floodwaters to automatically enter and exit. (d) The bottom of all required openings shall be no higher than one foot above the adjacent grade. (e) Openings may be equipped with screens, louvers, or other opening coverings or devices, provided they permit the automatic flow of floodwaters in both directions. (f) Foundation enclosures made of flexible skirting are not considered enclosures for regulatory purposes, and, therefore, do not require openings. Masonry or wood underpinning, regardless of structural status, is considered an enclosure and requires openings as outlined above. (D) All new and replacement public utilities, water mains and sanitary sewers shall be designed to minimize or eliminate infiltration and exfiltration and to ensure their structural integrity under flood conditions to the satisfaction of the director of the department of transportation and environmental services or the floodplain administrator. (E) Water heaters, furnaces, electrical distribution panels and other critical mechanical or electrical installations shall not be installed below the base flood elevation. Separate electrical circuits shall serve areas below the base flood elevation and shall be dropped from above. (F) Any proposed use of land, development and any new construction or substantial improvement of a building or structure within an A or AE zone, in conjunction with all other uses, existing or possessing a valid permit for construction, shall not increase the water-surface elevation of the l-percent annual chance flood by more than 0.5 foot. Any party proposing a land use or development or such construction or improvement within an A or AE zone shall furnish specific engineering data and information as to the effect of the proposed action on future flood heights and obtain approval from the director of the department of transportation and environmental services or the floodplain administrator prior to undertaking the action. (G) No building permit shall be issued for the construction or substantial improvement of a building or structure unless the applicant submits to the department of code administration a certification from a duly registered architect or engineer that the proposed construction (including prefabricated homes) or improvement meets the following requirements: (1) The construction shall be protected against flood damage; (2) The construction shall be designed (or modified) and anchored to prevent flotation, collapse or lateral movement of the building and structure; (3) The construction shall be built using materials and utility equipment that are resistant to flood damage; and, (4) The construction shall be built using methods and practices that will minimize flood damage. The certification required in section 6-307(H)(1) and (2) shall be based on the 1-percent annual chance flood level as noted on the flood insurance rate map. (H) Wherever floodproofing is utilized within the scope of this section 6-300, such floodproofing shall be done by approved methods. A registered professional engineer or architect shall certify the adequacy of the floodproofing design to withstand the stresses of the base flood and such plan shall cite the elevation to which the structure is floodproofed. All certified floodproofing shall be designed as passive and without the need for human intervention. Certifications must be in accordance with the NFIP Technical Bulletin 3, latest version. Such certification shall be provided on Federal Emergency Management Agency, National Flood Insurance Program, elevation certificate and/or floodproofing certificate as deemed applicable by the floodplain administrator. The building or code official shall maintain a file of such certifications, including the elevation of the lowest floor for structures that are elevated in lieu of watertight floodproofing. (I) Wherever pilings or columns are used for new construction and substantial improvements the following provisions shall apply: (1) The bottom of the lowest horizontal structural member of the lowest floor (excluding the pilings or columns) is elevated to or above the base flood level plus 1-foot. If the lowest horizontal structural member is parallel to the direction of wave approach or elevated at least two feet above the base flood level if the lowest horizontal structural member is perpendicular to the direction of wave approach; and (2) The pile or column foundation and structure attached thereto is anchored to resist flotation, collapse, and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Wind and water loading values shall each have a one percent chance of being equaled or exceeded in any given year (one percent annual chance). (3) A registered professional engineer or architect shall develop or review the structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction to be used are in accordance with accepted standards of practice for meeting the provisions of 6-307(J). (4) The floodplain administrator shall obtain the elevation (in relation to City Vertical Datum) of the bottom of the lowest horizontal structural member of the lowest floor (excluding pilings and columns) of all new and substantially improved structures. The floodplain administrator shall maintain a record of all such information. (5) All new construction and substantial improvements shall have the space below the lowest floor either free of obstruction or constructed with non-supporting breakaway walls, open wood-lattice work, or insect screening intended to collapse under wind and water loads without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system. For the purpose of this section, a breakaway wall shall have a design safe loading resistance of not less than 10 and no more than 20 pounds per square foot. Use of breakaway walls which exceed a design safe loading resistance of 20 pounds per square foot (either by design or when so required by local codes) may be permitted only if a registered professional engineer or architect certifies that the designs proposed meet the following conditions: (a) Breakaway wall collapse shall result from water load les than that which would occur during the base flood: and (b) The elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement, or other structural damage due to the effects of wind and water loads acting simultaneously on all building components (structural and nonstructural). Maximum wind and water loading values to be used in this determination shall each have a one percent chance of being equaled or exceeded in any given year. (6) The enclosed space below the lowest floor shall be used solely for parking of vehicles, building access, or storage. Such space shall not be partitioned into multiple rooms, temperature-controlled, or used for human habitation. The enclosed space shall be less than 300 square feet. (7) The use of fill for structural support of buildings is prohibited. When nonstructural fill is proposed in a coastal high hazard area, appropriate engineering analyses shall be conducted to evaluate the impacts of the fill prior to issuance of a permit.

Ask a question about Alexandria law

Corpus searches the Alexandria sections it holds and shows the ones that match, with their citations. Free, no sign-in.