For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 26-130 — Measurement procedure; maximum permitted levels

Code of the City of Chesapeake, Virginia (Supp. No. 148: codified through Ordinance No. 26-O-071, enacted August 11, 2026) · Chesapeake City Code § 26-130

Corpus is an independent public-information project, not the official City of Chesapeake website. Stable reference: corpuslaw.us/code/fb50e6e4-3af4-49d3-b332-32b00121d9db

Sec. 26-130. - Measurement procedure; maximum permitted levels.

(a) During the course of an investigation of a noise complaint under this division, the administrator shall employ the use of a type 1 or type 2 sound level meter that meets the specifications of the American National Standards Institute publications, Sections 1.4-1983 (R 2006) and 1.11-1986 (R 1998) thereof or such other equipment as may be prescribed by the Virginia Division of Purchases and Supply ("division") to determine the decibel level of sound. The chief of police shall be responsible for ensuring that all such equipment and devices meet or exceed the standards established by the division and shall maintain, inspect, calibrate, and test for accuracy all such equipment and devices on a schedule and in accordance with standards established by the division. The results obtained by any law-enforcement officer using a sound level meter deemed proper pursuant to the division standards shall be accepted as prima facie evidence of the decibel level of the sound in any court or legal proceeding where the decibel level of the sound is at issue. Unless otherwise required by the standards established by the division, the administrator shall make a sound level measurement utilizing the A weighting scale and the fast meter response. Decibels shall be measured and sound meters calibrated using the following reference value for dBAs and dBs: 2 × 10 (-5) N/m(2). In any court or legal proceeding in which a question arises about the calibration or accuracy of such equipment used to determine the decibel level of sound, a certificate, or a true copy thereof, showing the calibration or testing for accuracy of the equipment, and when and by whom the calibration or test was made, shall be admissible as evidence of the facts therein stated. No calibration or testing of such equipment shall be valid for longer than 12 months. Unless otherwise specifically stated herein, a measurement exceeding the noise spectra limit set forth in the maximum overall sound pressure level in the dBA column (Column 1) or the maximum octave band sound pressure level in the dB column of Table I below shall be deemed a violation of this article. The maximum octave band sound pressure levels in decibels (Column 3) shall be measured in conjunction with the octave band limits set out in the middle column of Table 1 (Column 2). (b) Notwithstanding anything to the contrary in subsection (a) of this section, no person shall operate or cause to be operated any source of sound at any location within the city or allow the creation of any noise on property he or she owns, leases, occupies or otherwise controls, which causes the sound level, measured on any other property, to exceed the maximum dBA (Column 1) or maximum dB (Column 3) sound pressure levels set out in Table 1 below. (c) Should the administrator determine the noise to be of an impulsive character (such as hammering, riveting or amplified bass music) or contain a steady, pure tone (such as a whine, screech or hum), the standard limits set forth in the maximum dB (Column 1) of Table 1 shall be reduced by five (5) dB. (d) Sound pressure levels shall be measured from the property at which a complaint is filed or from any property from which the noise can be heard, using the closest point of such property to the source of the noise. The area zoning classification used to determine a violation of the maximum sound pressure levels set out in Table 1 shall refer to the zoning classification or use, or in the case of mixed use areas and planned unit developments, the land use designation of the property from which the complaint is made or the sound is heard. (e) The city manager or designee shall develop and implement standard measurement procedures for use in operating a sound level meter, which procedures may be revised by the city manager or designee from time to time as deemed necessary. The procedures shall conform with the standards established by the division as provided in subsection (a) above. Unless incorporating a requirement of state law, the procedures shall serve as guidance and shall not be deemed a part of this article. Table 1. Maximum Sound Pressure Levels Column 1 | Column 2 | Column 3 Area Zoning Classification or Land Use Designation in Mixed Use and Planned Unit Developments | Maximum dBA or Measurement of Overall Sound Pressure Level | Octave Band Limit Center Frequency (Hertz (Hz)) | Maximum dB or Measurement of Maximum Sound Pressure Level in Each Octave Band Residential | 55 | 31.5 | 70 63 | 69 125 | 64 250 | 59 500 | 53 1,000 | 47 2,000 | 42 4,000 | 38 8,000 | 35 Commercial | 60 | 31.5 | 75 63 | 74 125 | 69 250 | 64 500 | 58 1,000 | 52 2,000 | 47 4,000 | 43 8,000 | 40 Agricultural | 60 | 31.5 | 75 63 | 74 125 | 69 250 | 64 500 | 58 1,000 | 52 2,000 | 47 4,000 | 43 8,000 | 40

(Ord. No. 09-O-129, 11-24-09; Ord. No. 10-O-064, 6-8-10)

Ask a question about Chesapeake law

Corpus searches the Chesapeake sections it holds and shows the ones that match, with their citations. Free, no sign-in.