§ 6-1602. - Development standards.
A. General site standards for multi-family development. (The Chesapeake health department may require larger lots, widths and setbacks where deemed necessary for adequate sewage disposal.) 1. Minimum lot size, 15,000 square feet. (Note: Multifamily dwellings having a height in excess of thirty-five (35) feet shall obtain a conditional use permit in accordance with article 17 of this Code.) 2. Minimum lot width, 90 feet. Minimum lot frontage, 72 feet. 3. Principal building setback (required yards). a. From public streets, 25 feet. From private streets, alleys, lanes or drive aisles, fifteen (15) feet from the edge of the pavement. (Setback from public streets shall be measured from the reservation line established in accordance with the city's adopted Master Transportation Plan. Where a reservation line cannot be established under the provisions of the adopted Master Transportation Plan, setbacks shall be measured as provided for in section 19-202.) b. From certain lot lines. From lot lines adjacent to property zoned or used for single-family detached development where the multifamily building contains more than four (4) dwelling units and/or exceeds two floors in height. i. Side yard, 15 feet plus 15 feet for each additional four dwelling units per building and/or additional floor. ii. Rear yard, 25 feet plus 15 feet for each additional four dwelling units per building and/or additional floor. c. From all other lot lines. i. Side yard, 15 feet. ii. Rear yard, 25 feet. d. Accessory building setbacks. Notwithstanding anything to the contrary in this Code, all accessory buildings and structures may be placed within 5 feet of a private alley, lane or drive aisle, not exceeding 24 feet in width, provided that the private alley, lane or drive aisle is designed to provide access to the side or rear yard of a dwelling unit in a multifamily district for use by the residents of such unit. The 5-foot setback shall be measured from the edge of pavement of said private alley, lane or drive aisle. All other setback requirements set out in article 14 of this Code for accessory buildings and structures in a multifamily district shall apply. e. Setbacks from parking areas. All buildings must be located a minimum of 15 feet from all parking bays and common parking areas. f. Setbacks between buildings. A minimum of 15 feet shall be provided between buildings. For those multifamily developments with buildings exceeding three stories, an additional 10 feet shall be provided between buildings. 4. Maximum lot coverage of all buildings and roofed structures, 35 percent. 5. Maximum building height, 35 feet. (Note: This maximum building height may be increased in accordance with section 19-800 et seq. Under section 19-205, this maximum building height may be exceeded upon approval of a conditional use permit.) B. Off-street parking. The minimum off-street parking requirements for each use in the R-MF-1 district shall be determined from the standards set forth for the applicable parking group as defined in section 19-411 and from the "parking" column on the use schedule established under section 6-2102. All off-street parking spaces shall be paved in accordance with the specifications established in section 19-406. C. Special standards for multifamily developments. 1. All dwelling units shall be served by public utility facilities. 2. The development project shall be designed to promote harmonious relationships with surrounding properties through attention to the type, orientation and spacing/setback of buildings, preservation and maintenance of natural vegetation, location of recreational areas, open space, parking areas, grading, landscaping and screening/buffering. 3. The density standards for multifamily development are set out in article 5 of this zoning ordinance. 4. Reserved. 5. All new utility lines, including electrical, telephone and cable television shall be placed below ground. 6. All streets within a multifamily development, including, but not limited to, those in R-MF-1 and R-MF-2 districts shall be designed and constructed in accordance with the following standards and specifications: a. Minimum street widths shall be 30 feet, except in the following circumstances: i. Where 40 or fewer attached multifamily dwelling units, or 24 or fewer detached condominium units, front or have direct access to a private street, the minimum width of such street shall be 24 feet. In calculating the number of units that front or have direct access to a private street, the term "street" shall be construed to include the full length of a continuous privately owned road, without regard to intersecting streets, alleys, drive aisles, lanes and other rights-of-way, whether public or privately owned. ii. Where a private alley, lane or drive aisle is designed to provide access to the side or rear of a dwelling unit in a multifamily district for use by the residents of such unit, the minimum width of such alley, lane or drive aisle shall be 20 feet. Greater minimum widths may be required in accordance with the Public Facilities Manual as necessary to accommodate parking or other needs of the development. iii. Notwithstanding the foregoing, any private street on which public school buses will travel shall have a minimum width of 30 feet. b. All streets shall have a minimum centerline radius of 75 feet for streets 30 feet in width, and 50 feet for streets 24 feet in width, with no minimum tangent line. The director of development and permits, or designee, may adjust these standards where deemed necessary to accommodate unique design conditions. c. Minimum pavement design shall meet the specifications applied to public streets as set forth in the Public Facilities Manual. d. Minimum lighting standards shall meet the specifications applied to public streets as set forth in the Public Facilities Manual, provided that the director of development and permits, or designee, may approve alternate standards of lighting where, due to placement and design of the lighting devices, the director determines that the lighting will be equivalent to that provided on public streets. In addition, all parking area lighting within a multifamily development shall conform to the standards of the director of development and permits, or designee. e. Curb and guttering shall be required on private streets in accordance with the specifications set out in the Public Facilities Manual, except that curb and guttering may be waived by the director of development and permits, or designee, for private alleys, lanes and drive aisles, not exceeding twenty-four (24) feet in width, where designed to provide access by residents to the side or rear of a dwelling unit in a multi-family zoning district. No rolled curbs shall be permitted on private streets, except as allowed by the director of development and permits, or designee, for such private alleys, lanes, and drive aisles described above. All parking area lighting within a multifamily development shall conform to the standards of the director of development and permits, or designee. 7. The primary access and any secondary connections to the development project shall maximize the safety and adequacy of adjoining property and streets, as determined by the director of development and permits or designee. 8. The storage of recreational vehicles and boats shall be prohibited unless a common storage/parking area is provided on the approved preliminary site plan scaled to the size of the development. Such area(s) shall be surfaced to provide all-weather access and shall be appropriately screened by landscaping and fencing. 9. Evidence of compliance with the above standards shall be demonstrated through the preparation of a preliminary site plan in accordance with article 18 of this Code. D. Development standards for single-family detached dwelling unit subdivisions in the multi-family zoning districts. All subdivisions for the development of single-family detached dwelling units on individual lots shall comply with the development standards set forth for the R-10s, single-family district in accordance with section 6-1200 et seq. of this Code. E. Other development standards. Other development standards pertaining to all residential districts are set out in section 6-2000 et seq.
(Ord. No. 95-O-216, 11-21-95; Ord. No. 96-O-072, 5-21-96; Ord. No. 98-O-055, 4-21-98; Ord. No. 00-O-009, 1-18-00; Ord. No. 04-O-176, 12-21-04; Ord. No. 05-O-015, 3-8-05; Ord. No. 09-O-051, 5-19-09; Ord. No. 17-O-081, 11-21-17; Ord. No. 21-O-142, 12-21-21)
Ask a question about Chesapeake law
Corpus searches the Chesapeake sections it holds and shows the ones that match, with their citations. Free, no sign-in.