Sec. 22-52. - Noise attenuation.
(a) Any structure or addition classified as "Use Group R" of the International Building Code, as amended, built or placed within the Noise Contour District on or after October 1, 1992 shall be constructed to provide acoustical treatment measures which achieve a maximum interior noise level of 45 dB DNL. Acoustical treatment measures shall not be required of garages, storage areas, or any other structure whose primary function is not the habitation of people. (1) Within the 75 or greater dB DNL contour line, the use of roof and exterior wall assemblies which have a laboratory sound transmission class (STC) of at least 49, and doors and windows which have a laboratory STC of at least 38 shall be required. (2) Within the 70—74 dB DNL contour line, the use of roof and exterior wall assemblies which have a laboratory sound transmission class (STC) of at least 44, and doors and windows which have a laboratory STC of at least 33 shall be required. (3) Within the 65—69 dB DNL contour line the use of roof and exterior wall assemblies which have a laboratory sound transmission class (STC) of at least 39, and doors and windows which have a laboratory STC of at least 28 shall be required. (b) In lieu of the materials specified in section 22-52(a), certification by an acoustical engineer that the construction practices and/or materials of the structure shall achieve the required interior noise level shall be submitted to the building official for approval prior to the release of any building permits. (c) For purposes of this article, the term "day-night average sound level (DNL)" is a twenty-four (24) hour energy average sound level expressed in dBA, with a ten-decibel penalty applied to noise occurring between 10:00 p.m. and 7:00 a.m., and the term "sound transmission class (STC) rating" is a single number rating characterizing the sound reduction performance of a material tested in accordance with ASTM E 90-90, "Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions".
(Ord. No. 1063, 8-27-92; Ord. No. 1071, 12-9-92; Ord. No. 1449, 12-14-06; Ord. No. 11-0006, 6-8-11)
Ask a question about Hampton law
Corpus searches the Hampton sections it holds and shows the ones that match, with their citations. Free, no sign-in.