§ 36-85 — Disinfection equipment; chlorinator room
Code of the City of Hampton, Virginia (Supp. No. 32: codified through Ordinance No. 26-0009, adopted June 10, 2026) · Hampton City Code § 36-85
Corpus is an independent public-information project, not the official City of Hampton website. Stable reference: corpuslaw.us/code/431a4b21-50c8-4796-8c36-90f1bdc94f3c
Sec. 36-85. - Disinfection equipment; chlorinator room.
All public swimming pools, spas and/or hot tubs shall be provided with disinfectant-feeding equipment. The disinfection equipment shall be capable of applying a dose sufficient to maintain minimum free disinfectant residuals as required by section 36-86. Chlorine gas feeding equipment and chlorine gas cylinders shall be installed in an enclosed space or room, separate from the filter room, equipped with a door capable of being locked. Such room shall be equipped with a forced draft fan exhausting to the outside from the floor level and a fresh air inlet shall be provided near the ceiling. The exhaust fan discharge shall terminate at least twelve (12) feet above any area that may be occupied by any person. Forced draft apparatus shall have sufficient capacity to exhaust the contents of the room in not more than three (3) minutes. The chlorine gas tanks shall be protected from direct sunlight and fastened in place during storage and use. A laboratory approved type gas mask shall be provided where chlorine gas is being utilized. This shall be located accessible to, but outside of, the chlorinator room.
(Ord. No. 1397, 4-13-05; Ord. No. 1458, 1-24-07)