§ 35.2-59.8.3 — Elevation and construction standards [44 CFR 60.3]

Code of Ordinances of the City of Lynchburg, Virginia (Codified through Ordinance No. O-25-021, adopted March 11, 2025. (Supp. No. 10)) · Lynchburg Code of Ordinances § 35.2-59.8.3

Corpus is an independent public-information project, not the official City of Lynchburg website. Stable reference: corpuslaw.us/code/c5f8f555-9a5d-48cc-8ece-5643ffc60c83

Sec. 35.2-59.8.3. - Elevation and construction standards [44 CFR 60.3].

In all identified special flood hazard areas where base flood elevations have been provided in the FIS or generated by a certified professional in accordance with section 35.2-59.7.4, the following provisions shall apply: (a) Residential construction. New construction or substantial improvement of any residential structure (including replacement manufactured homes) in the AE and A Zones with detailed base flood elevations shall have the lowest floor, including basement, elevated to or above the base flood level plus 12 inches. (b) Non-residential construction. (1) New construction or substantial improvement of any commercial, industrial, or non-residential building (or manufactured home) shall have the lowest floor, including basement, elevated to or above the base flood level plus 12 inches. (2) Non-residential buildings located in the AE Zone may be floodproofed in lieu of being elevated provided that all areas of the building components below the elevation corresponding to the BFE plus 12 inches are water tight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification, including the specific elevation (in relation to mean sea level) to which such structures are floodproofed, shall be maintained by the floodplain administrator. (c) Space below the lowest floor. In AE and A Zones, fully enclosed areas, of new construction or substantially improved structures, which are below the regulatory flood protection elevation shall: (1) Not be designed or used for human habitation, but shall be used solely for parking of vehicles, building access, or limited storage of maintenance equipment used in connection with the premises. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment (standard exterior door), or entry to the living area (stairway or elevator). (2) Be constructed entirely of flood resistant materials below the regulatory flood protection elevation: (3) Include measures to automatically equalize hydrostatic flood forces on walls by allowing for the entry and exist of floodwaters. To meet this requirement, the openings must either be certified by a professional engineer or architect or meet the following minimum design criteria: i. Provide a minimum of two openings on different sides of each enclosed area subject to flooding. ii. The total net area of all openings must be at least one square inch for each square foot of enclosed area subject to flooding. iii. If a building has more than one enclosed area, each area must have openings to allow floodwaters to automatically enter and exit. iv. The bottom of all required openings shall be no higher than one foot above the adjacent grade. v. Openings may be equipped with screens louvers, or other opening coverings or devices, provided they permit the automatic flow of floodwaters in both directions. vi. Foundation enclosures made of flexible skirting are not considered enclosures for regulatory purposes, and, therefore, do not require openings. Masonry or wood underpinning, regardless of structural status, is considered an enclosure and requires openings as outlined above. (c) Accessory structures. Accessory structures of any size shall be prohibited within the SFHA and no variance shall be granted for accessory structures. (d) Standards for replacement manufactured homes and recreational vehicles. (1) In the AE and A Zones, all replacement manufactured homes placed must meet all the requirements for new construction, including the elevation and anchoring requirements in section 35.2-59.8.2 and section 35.2-59.8.3. Such anchoring shall be completed to resist flotation, collapse, or lateral movement by providing over-the-top and frame ties to ground anchors in either of the following arrangements: (i) over-the-top ties at each corner plus one frame tie at the middle of each side; or (ii) frame ties at each corner plus no less than five evenly spaced additional frame ties per side. All ties to the ground shall be able to carry a force of 4,800 pounds. This standard shall be in addition to and consistent with applicable state anchoring requirements for resisting wind forces. (2) All recreational vehicles placed on sites must either: i. Be on the site for fewer than 180 consecutive days, be fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices and has no permanently attached additions); or ii. Meet all the requirements for manufactured homes in section 35.2-59.8.3(d)(1) above.

(Ord. No. O-25-021, 3-11-25)

Ask a question about Lynchburg law

Corpus searches the Lynchburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.