§ 45-3115 — District provisions
Code of Ordinances, City of Newport News, Virginia (Supp. No. 82: codified through Ordinance No. 8209-26, enacted September 22, 2026) · Newport News City Code § 45-3115
Corpus is an independent public-information project, not the official City of Newport News website. Stable reference: corpuslaw.us/code/0ad7afe1-3118-4d59-9a96-6c420b7170fa
Sec. 45-3115. - District provisions.
(a) Permit and application requirements. (1) Permit requirement. All uses, activities, and development occurring within any floodplain district, including placement of manufactured homes, shall be undertaken only upon the issuance of a zoning permit. Such development shall be undertaken only in strict compliance with the provisions of this division and with other applicable codes and ordinances, as amended, such as the Virginia Uniform Statewide Building Code (VA USBC) and the City of Newport News Subdivision Regulations. Prior to the issuance of any such permit, the floodplain administrator shall require all applications to include compliance with all applicable state and federal laws and shall review all sites to assure they are reasonably safe from flooding. Under no circumstances shall any use, activity, and/or development adversely affect the capacity of the channels or floodways of any watercourse, drainage ditch, or any other drainage facility or system. (2) Site plans and permit applications. All applications for development within any floodplain district and all building permits issued for the floodplain shall incorporate the following information: a. The elevation of the base flood at the site. b. The elevation of the lowest floor (including basement) or, in V zones, the lowest horizontal structural member. c. For structures to be floodproofed (non-residential only), the elevation to which the structure will be floodproofed. d. Topographic information showing existing and proposed ground elevations. e. For Zones V, VE, and Coastal A, where there is enclosure space below the lowest floor and it is less than three hundred (300) square feet, a signed Nonconversion Agreement must be submitted with the deed. The agreement states that the owner will not convert or alter what has been constructed and approved. Violation of the agreement is considered a violation of this district and, therefore, subject to the same enforcement procedures and penalties. The Nonconversion Agreement is to be signed when the building is completed and the owner applies for a certificate of occupancy or a use permit. This is done after the final inspection, when the Floodplain Administrator confirms that the building meets all building code and flood damage prevention ordinance requirements. (b) General standards. The following provisions shall apply to all permits: (1) New construction and substantial improvements shall be according to the this division and the Virginia Uniform Statewide Building Code (VA USBC), and anchored to prevent flotation, collapse or lateral movement of the structure. (2) Manufactured homes shall be anchored to prevent flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard shall be in addition to and consistent with applicable state anchoring requirements for resisting wind forces. (3) New construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage. (4) New construction or substantial improvements shall be constructed by methods and practices that minimize flood damage. (5) Electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities, including duct work, shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. All systems must meet the requirements of city and state building requirements. (6) Utility systems such as water, sewer, gas and electrical systems shall be located and constructed to minimize or eliminate flood damage and infiltration of flood waters into the systems and discharges from such systems into flood waters. On-site waste disposal systems shall be located and constructed to avoid their impairment or contamination during flooding. Manhole tops shall either be elevated to a minimum of two (2) feet above the level of the one (1) percent annual chance flood, or have installed water-tight frames and covers, or utilize manhole inserts to eliminate the entrance of flood water into the system. (7) In addition to provisions (1)—(6) above, in all special flood hazard areas, the additional provisions shall apply: a. Prior to any proposed alteration or relocation of any channels or of any watercourse, stream, etc., within this jurisdiction a permit shall be obtained from the U.S. Corps of Engineers, the Virginia Department of Environmental Quality, and the Virginia Marine Resources Commission (a joint permit application is available from any of these organizations.) Furthermore, in riverine areas, notification of the proposal shall be given by the applicant to all affected adjacent jurisdictions, the department of conservation and recreation (division of dam safety and floodplain management), other required agencies, and the Federal Emergency Management Agency. b. The flood-carrying capacity within an altered or relocated portion of any watercourse shall be maintained. (8) New or substantially improved Critical Facilities may not be located within the mapped one (1) percent annual chance floodplain, to include all of the above zones and also the zones designated as having a 0.2 percent annual chance of flooding on any flood map or flood insurance study. In this area no emergency service, medical service, or governmental records storage shall be allowed. (9) The use of fill for structural support of buildings is prohibited. When non-structural fill is proposed, appropriate engineering analyses shall be conducted to evaluate the impacts of the fill prior to issuance of a development permit. Compensatory storage may be utilized if engineering data shows the site is hydraulically equivalent and the Floodplain Administrator approves the plans for each compensatory storage area. The Floodplain Administrator may approve the permit for the placement of fill provided that the proposed fill within the floodplain: a. Shall be mitigated to result in no decrease in flood storage volume on the site; b. Shall be mitigated entirely on the same site that will incur the fill; c. Shall be contiguous to the existing floodplain that is being filled; and d. Shall be limited to the smallest amount of area and volume possible to correct irregularities within the boundary of the project. e. The combined areas of fill and mitigation shall not exceed five (5) percent of the total area within the floodplain located on the site that will incur the fill. (c) Elevation and construction standards. In all identified flood hazard areas where base flood elevations have been provided in the FIS or generated by a certified in accordance with accepted engineering practices the following provisions shall apply: (1) Residential construction. New construction or substantial improvement of any residential structure (including manufactured homes) in SFHA zones AE, AO, and A with detailed base flood elevations shall at a minimum have the lowest floor, including basement, elevated to two (2) feet above the base flood level. See section 45-3114(b)(5) for requirements in the Coastal A, VE, and V zones. (2) Non-residential construction. New construction or substantial improvement of any commercial, industrial, or non-residential building (or manufactured home): a. Shall at a minimum have the lowest floor, including basement, elevated to two (2) feet above the base flood level. See section 45-3114(b)(5) for requirements in the Coastal A, VE, and V zones. b. Buildings located in all AE zones may be floodproofed in lieu of being elevated provided that all areas of the building components below the elevation corresponding to the BFE plus two (2) feet are watertight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification, including the specific elevation (in relation to mean sea level) to which such structures are floodproofed, shall be maintained by the floodplain administrator. (3) Space below the lowest floor. In zones A, AO, and AE, fully enclosed areas, of new construction or substantially improved structures, which are below the regulatory flood protection elevation shall: a. Not be designed or used for human habitation, but shall only be used for parking, building access and storage in connection with the premises. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment (standard exterior door), or entry to the living area (stairway or elevator). b. Be constructed entirely of flood resistant materials below the regulatory flood protection elevation. c. Include measures to automatically equalize hydrostatic flood forces on walls by allowing for the entry and exit of floodwaters. To meet this requirement, the openings must either be certified by a professional engineer or architect or meet the following minimum design criteria: 1. Provide a minimum of two (2) openings on different sides of each enclosed area subject to flooding. 2. The total net area of all openings must be at least one (1) square inch for each square foot of enclosed area subject to flooding. 3. If a building has more than one (1) enclosed area, each area must have openings to allow floodwaters to automatically enter and exit. 4. The bottom of all required openings shall be no higher than one (1) foot above the adjacent grade. 5. Openings may be equipped with screens, louvers, or other opening coverings or devices, provided they permit the automatic flow of floodwaters in both directions. 6. Foundation enclosures made of flexible skirting are not considered enclosures for regulatory purposes, and, therefore, do not require openings. Masonry or wood underpinning, regardless of structural status, is considered an enclosure and requires openings as outlined above. (d) Accessory Structures. (1) Accessory structures in the SFHA shall comply with the elevation requirements and other requirements of this division or, if not elevated or dry floodproofed, shall: a. Not be used for human habitation; b. Be limited to no more than six hundred (600) square feet in total floor area; c. Be useable only for parking of vehicles or limited storage; d. Be constructed with flood damage-resistant materials below the base flood elevation plus required freeboard; e. Be constructed and placed to offer the minimum resistance to the flow of floodwaters; f. Be anchored to prevent flotation; g. Have electrical service and mechanical equipment elevated to or above the base flood elevation plus required freeboard; and h. Shall be provided with flood openings which shall meet the following criteria: 1. There shall be a minimum of two (2) flood openings on different sides of each enclosed area; if a building has more than one (1) below the lowest floor, each such enclosure shall have flood openings on exterior walls. 2. The total net area of all flood openings shall be at least one (1) square inch for each square foot of enclosed area (non-engineered flood openings), or the flood openings shall be engineered flood openings that are designed and certified by a licensed professional engineer to automatically allow entry and exit of floodwaters. 3. The bottom of each flood opening shall be one (1) foot or less above the higher of the interior floor or grade, or the exterior grade, immediately below the opening. 4. Any louvers, screens or other covers for the flood openings shall allow the automatic flow of floodwaters into and out of the enclosed area. 5. A signed Non-Conversion Agreement shall be recorded on the property deed. (e) Standards for manufactured homes and recreational vehicles. (1) All manufactured homes placed, or substantially improved, on individual lots or parcels, must meet all the requirements for new construction, including the elevation and anchoring requirements in section 45-3115(b) and (c). (2) All recreational vehicles placed on sites must either: a. Be on the site for fewer than one hundred eighty (180) consecutive days, be fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices and has no permanently attached additions); or b. Meet all the requirements for manufactured homes in section 45-3115(d)(1). (f) Historic Structures. Variances for repair or rehabilitation of historic structures may be granted upon a determination that the proposed repair or rehabilitation will not preclude the structure's continued designation as a historic structure and the variance is the minimum necessary to preserve the historic character and design of the structure. Structures must meet the requirements in the definition in section 45-3112. (g) Standards for subdivision proposals. (1) All subdivision proposals shall be consistent with the need to minimize flood damage; (2) All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage; (3) All subdivision proposals shall have adequate drainage provided to reduce exposure to flood hazards; and (4) Base flood elevation data shall be obtained from other sources or developed using detailed methodologies, hydraulic and hydrologic analysis, comparable to those contained in a flood insurance study for subdivision proposals and other proposed development proposals (including manufactured home parks and subdivisions) that exceed five (5) lots or five (5) acres, whichever is the lesser. (h) Obtaining permits prior to work. Within any flood hazard district, the property owner or corporation having fee simple title or rights of construction to a property, shall obtain a permit for all proposed development prior to the initiation of work.
(Ord. No. 8195-26)
Ask a question about Newport News law
Corpus searches the Newport News sections it holds and shows the ones that match, with their citations. Free, no sign-in.