§ 14.1-11 — District provisions
Code of the City of Portsmouth, Virginia (Codified through Ordinance No. 2026-64, enacted June 23, 2026. (Supp. No. 66)) · Portsmouth City Code § 14.1-11
Corpus is an independent public-information project, not the official City of Portsmouth website. Stable reference: corpuslaw.us/code/8f8781c4-09e2-495f-8950-cf2c3b5051fe
Sec. 14.1-11. - District provisions.
(a) General standards. The following provisions shall apply to all permits: (1) New construction, substantial improvements, and repairs for substantial damage shall be according to the VA USBC and this chapter, and anchored to prevent flotation, collapse, or lateral movement of the structure. (2) New construction, substantial improvements. and repairs for substantial damage shall be constructed with materials and utility equipment resistant to flood damage below the design flood elevation (DFE) in cases when those elements are allowed below the DFE. (3) New construction, substantial improvements, and repairs for substantial damage shall be constructed by methods and practices that minimize flood damage. (4) Electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities, including duct work, shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. (5) New and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system. (6) New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters. (7) On-site waste disposal systems shall be designed to current City of Portsmouth standards and shall be located and constructed to avoid impairment to them or contamination from them during flooding. (b) Floodplain requirements. (1) The following provisions shall apply within the floodway district of an AE zone: a. Within any floodway area, no encroachments, including fill, new construction, substantial improvements, or other development shall be permitted unless it has been demonstrated through hydrologic and hydraulic analysis performed in accordance with standard engineering practice that the proposed encroachment will not result in any increase in flood levels within the community during the occurrence of the base flood discharge. Hydrologic and hydraulic analysis shall be undertaken only by professional engineers or others of demonstrated qualifications, who shall certify that the technical methods used correctly reflect currently-accepted technical concepts. Studies, analyses, computations, etc., shall be submitted in sufficient detail to allow a thorough review by the floodplain administrator. b. Development activities which increase the water surface elevation of the base flood may be allowed, provided that the applicant first applies — with the City of Portsmouth's endorsement — for a conditional letter of map revision (CLOMR), and receives the approval of the Federal Emergency Management Agency. c. If subsection 14.1-11(b)(1)a. is satisfied, all new construction and substantial Improvements shall comply with all applicable flood hazard reduction provisions in sections 14.1-10 and 14.1-11 of this Code. d. The placement of manufactured homes (mobile homes) is prohibited except in an existing manufactured home (mobile home) park or subdivision. A replacement manufactured home is prohibited. (2) The following provisions shall apply within an AE or AH zone [44 CFR 60.3(c)]. a. Until a regulatory floodway is designated, no new construction, substantial improvements, or other development (including fill) shall be permitted within the areas of special flood hazard, designated as Zones A1-30 and AE or AH on the FIRM, unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one foot at any point within the City of Portsmouth. b. Development activities in Zones A1-30 and AE or AH, on the City of Portsmouth's FIRM which increase the water surface elevation of the base flood by more than one foot may be allowed, provided that the applicant first applies — with the City of Portsmouth's endorsement — for a conditional letter of map revision, and receives the approval of the Federal Emergency Management Agency. (3) The following provisions shall apply within an A zone [44 CFR 60.3(b)]. a. The Approximated Floodplain District shall be that floodplain area for which no detailed flood profiles or elevations are provided, but where a 100-year floodplain boundary has been approximated. Such areas are shown as Zone A on the maps accompanying the FIS. For these areas, the base flood elevations and floodway information from federal, state, and other acceptable sources shall be used, when available. Where the specific one percent annual chance flood elevation cannot be determined for this area using other sources of data, such as the U.S. Army Corps of Engineers Floodplain Information Reports, U.S. Geological Survey Flood-Prone Quadrangles, etc., then the applicant for the proposed use, development and/or activity shall determine this base flood elevation. For development proposed in the approximate floodplain the applicant must use technical methods that correctly reflect currently accepted non-detailed technical concepts, such as point on boundary, high water marks, or detailed methodologies hydrologic and hydraulic analyses. Studies, analyses, computations, etc., shall be submitted in sufficient detail to allow a thorough review by the floodplain administrator. b. The floodplain administrator reserves the right to require a hydrologic and hydraulic analysis for any development. When such base flood elevation data is utilized, the lowest floor shall be elevated to the design flood elevation (DFE). c. During the permitting process, the floodplain administrator shall obtain: 1) The elevation of the lowest floor (including HVAC, all duct work, and the basement) of all new and substantially improved structures; and 2) If the structure is non-residential has been flood-proofed in accordance with the requirements of this article, the elevation (in relation to mean sea level) to which the structure has been flood-proofed. Residential structures shall not be flood-proofed. d. Base flood elevation data shall be obtained from other sources or developed using detailed methodologies comparable to those contained in a FIS for subdivision proposals and other proposed development proposals (including manufactured home parks and subdivisions) that exceed 50 lots or five acres, whichever is the lesser. (4) The following provisions shall apply within an AO zone [44 CFR 60.3(c)]. a. All new construction and substantial improvement of residential structures shall have the lowest floor, including basement, elevated to or above the flood depth specified on the FIRM, above the highest adjacent grade at least as high as the depth number specified in feet on the FIRM. If no flood depth number is specified, the lowest floor, including basement, shall be elevated no less than two feet above the highest adjacent grade. b. All new construction and substantial improvements of non-residential structures shall: 1) Have the lowest floor, including basement, elevated to or above the flood depth specified on the FIRM, above the highest adjacent grade at least as high as the depth number specified in feet on the FIRM. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least two feet above the highest adjacent grade; or 2) Together with attendant utility and sanitary facilities be completely flood-proofed to the specified flood level so that any space below that level is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. c. Adequate drainage paths around structures on slopes shall be provided to guide floodwaters around and away from proposed structures. (5) The following provisions shall apply for the Coastal A Zone (limits of moderate wave action). Buildings and structures within this zone shall comply with V zone standards with the lowest supporting member elevated to or above the base flood elevation plus 3.0 feet of freeboard, and must comply with the provisions in paragraph b.2. in this section (14.1-11) (provisions for zones AE or AH) and paragraphs a. and d. in this section (14.1-11). (6) The following provisions shall apply for the VE or V Zones (Coastal High Hazard areas). a. All new construction and substantial improvements in Zones V and VE (V if no base flood elevation is available) shall be elevated on pilings or columns so that: 1) The bottom of the lowest horizontal structural member of the lowest floor (including all HVAC and duct work but excluding the pilings or columns) is elevated above the base flood level by at least three feet; and 2) The pile or column foundation and structure attached thereto is anchored to resist flotation, collapse, and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Wind and water loading values shall each have a one percent chance of being equaled or exceeded in any given year (one-percent annual chance). b. A registered professional engineer or architect shall develop or review the structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction to be used are in accordance with accepted standards of practice for meeting the provisions of Section 14.1-11(b)(6)(a)(2) of this code. c. The floodplain administrator shall obtain the elevation (in relation to mean sea level) of the bottom of the lowest horizontal structural member of the lowest floor (including all HVAC and duct work, but excluding pilings and columns) of all new and substantially improved structures in Zones V and VE. The floodplain management administrator shall maintain a record of all such information. d. All new construction shall be located at least 50 feet landward of the reach of mean high tide. e. All new construction and substantial improvements shall have the space below the lowest floor either free of obstruction or constructed with non-supporting breakaway walls, open wood-lattice work, or insect screening intended to collapse under wind and water loads without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system. For the purpose of this section, a breakaway wall shall have a design safe loading resistance of not less than ten and no more than 20 pounds per square foot. Use of breakaway walls which exceed a design safe loading resistance of 20 pounds per square foot (either by design or when so required by local codes) may be permitted only if a registered professional engineer or architect certifies that the designs proposed meet the following conditions: 1) Breakaway wall collapse shall result from water load less than that which would occur during the base flood; and 2) The elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement, or other structural damage due to the effects of wind and water loads acting simultaneously on all building components (structural and nonstructural). Maximum wind and water loading values to be used in this determination shall each have a one percent chance of being equaled or exceeded in any given year. f. The enclosed space below the lowest floor shall be used solely for parking of vehicles, building access, or storage. Such space shall not be partitioned into multiple rooms, temperature-controlled, or used for human habitation. g. The use of fill for structural support of buildings is prohibited. When non-structural fill is proposed in a coastal high hazard area, appropriate engineering analyses shall be conducted to evaluate the impacts of the fill prior to issuance of a development permit. h. The man-made alteration of sand dunes and mangrove stands, which would increase potential flood damage, is prohibited. i. All recreational vehicles placed in V-zones shall be on site for fewer than 180 consecutive days, be fully licensed and ready for highway use or meet the same standards as for conventional housing in V-zones. (c) Additional provisions for watercourse. (1) Prior to any proposed alteration or relocation of any channels or of any watercourse, stream, etc., within this jurisdiction, a permit shall be obtained from the U.S. Corps of Engineers, the Virginia Department of Environmental Quality, and the Virginia Marine Resource Commission (a joint permit application is available from any of these organizations). Furthermore, in riverine areas, notification of the proposal shall be given by the applicant to all affected adjacent jurisdictions, the Department of Conservation and Recreation (Division of Dam Safety and Floodplain Management), other required agencies, and the Federal Emergency Management Agency. (2) The flood carrying capacity within an altered or relocated portion of any watercourse shall be maintained. (d) Elevation and construction standards. In all identified flood hazard areas where base flood elevations have been provided in the FIS or generated by a certified professional in accordance with subsection 14.1-11(b)(3) of this code the following provisions shall apply: (1) Residential construction. New construction or substantial improvement of any residential structure (including manufactured homes) in Zones A1-30, AE, AH and A with detailed base flood elevations shall have the lowest floor including HVAC, duct work, and basement, elevated to at least the design flood elevation which is the BFE plus 3.0 feet. No floodproofing below the design flood elevation (DFE) of residential construction is allowed. (2) Non-residential construction. New construction or substantial improvement of any commercial, industrial, or non-residential building (or manufactured home) shall have the lowest floor, including basement, elevated at least three feet above the base flood level. Buildings located in all A1-30, AE, and AH zones may be floodproofed in lieu of being elevated provided that all areas of the building components below the elevation corresponding to the BFE plus three feet are water tight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification, including the specific elevation (in relation to mean sea level) to which such structures are floodproofed, shall be maintained by the floodplain administrator. (3) Space below the lowest floor. In zones A, AE, AH, AO, and A1-A30, fully enclosed areas, of new construction or substantially improved structures, which are below the regulatory flood protection elevation shall: a. Not be designed or used for human habitation, but shall only be used for parking of vehicles. building access, or limited storage of maintenance equipment used in connection with the premises. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment (standard exterior door), or entry to the living area (stairway or elevator). b. Be constructed entirely of flood resistant materials below the design flood elevation which is the BFE plus three feet. c. Include measures to automatically equalize hydrostatic flood forces on walls by allowing for the entry and exit of floodwaters. To meet this requirement, the openings must either be certified by a professional engineer or architect or meet the following minimum design criteria; 1) Provide a minimum of two openings on different sides of each enclosed area subject to flooding. 2) The total net area of all openings must be at least one square inch for each square foot of enclosed area subject to flooding. 3) If a building has more than one enclosed area, each area must have openings to allow floodwaters to automatically enter and exit. 4) The bottom of all required openings shall be no higher than one foot above the adjacent grade. 5) Openings may be equipped with screens, louvers, or other opening coverings or devices, provided they permit the automatic flow of floodwaters in both directions. 6) Foundation enclosures made of flexible skirting are not considered enclosures for regulatory purposes, and, therefore, do not require openings. Masonry or wood underpinning, regardless of structural status, is considered an enclosure and requires openings as outlined above. (e) Prohibited uses. (1) The following uses shall be specifically prohibited within all "A", "AE", "V" and "VE" floodplain districts: a. Sanitary landfills, junkyards, outdoor storage of inoperative vehicles. b. Manufactured homes (except as a temporary use in accordance with subsection 14.1-10(c)). c. Surface mines and borrow pits. d. Manufacture, bulk storage, transformation or distribution of petroleum (except for retail sales), chemicalor asphalt products or any hazardous materials as defined in either or both of the following: 1) Superfund Amendment and Reauthorization Act of 1986. 2) Identification and Listing of Hazardous Wastes, 40 CFR section 261 (1987). a. Oil and oil products including petrochemicals. b. Radioactive materials. c. Any material transported or stored in large commercial quantities (such as 55-gallon drums) which is a very soluble acid or base, causes abnormal growth of an organ or organism, or is highly biodegradable, exerting a strong oxygen demand. d. Biologically accumulative poisons. e. Substances containing the active ingredients of poisons that are or were ever registered in accordance with the provisions of the Federal Insecticide, Fungicide, and Rodenticide Act, as amended (7 USC 135 et seq.). f. Substances highly lethal to mammalian or aquatic life. g. Storage or land application of industrial wastes. h. Outdoor storage of equipment, materials or supplies which are buoyant, flammable or explosive. (2) Nonconforming uses of this chapter notwithstanding, no expansion of any of the above uses located within the floodplain district shall be permitted. (f) Standards for subdivision proposals. (1) All subdivision proposals shall be consistent with the need to minimize flood damage; (2) All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage; (3) All subdivision proposals shall have adequate drainage provided to reduce exposure to flood hazards; and (4) Base flood elevation data shall be provided for subdivision proposals and other proposed development proposals (including manufactured home parks and subdivisions) that exceed 50 lots or five acres, whichever is the lesser.
(Ord. No. 2015-36, § 2(Exh. A), 6-9-2015)
Ask a question about Portsmouth law
Corpus searches the Portsmouth sections it holds and shows the ones that match, with their citations. Free, no sign-in.