Sec. 4.9. - V and VE Zone requirements.
The following provisions shall apply within Coastal A Zones and Coastal High Hazard Areas: A. All new construction and substantial improvements, including to manufactured homes, shall be elevated on pilings or columns so that: 1. The bottom of the lowest horizontal structural member of the lowest floor (excluding the pilings or columns) is elevated to a minimum of three (3) feet above the base flood elevation; and 2. The pile or column foundation and structure attached thereto is anchored to resist flotation, collapse, and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Wind and water loading values shall each have a one (1) percent chance of being equaled or exceeded in any given year. B. A professional engineer or architect licensed by the Commonwealth of Virginia shall develop or review the structural design, specifications, and plans for the construction and shall certify that the design and methods of construction to be used are in accordance with accepted standards of practice for meeting the provisions of article IV, section 4.6 A. A V Zone Design Certificate shall be submitted to Permits and Inspections with plans for a building permit. C. The floodplain administrator shall obtain the elevation (in relation to NAVD88) of the bottom of the lowest horizontal structural member of the lowest floor (excluding pilings and columns) of all new and substantially improved structures in Zones V and VE. The floodplain administrator shall maintain a record of all such information. D. All new construction shall be located landward of the reach of mean high tide. E. A professional engineer or architect licensed by the Commonwealth of Virginia shall develop and seal the structural design, specifications and plans for construction, and shall certify that the design and methods of construction to be used meet the following requirements: 1. All new construction and substantial improvements shall have the space below the lowest floor either free of obstruction or constructed with non-supporting breakaway walls, open wood-lattice work, or insect screening intended to collapse under wind and water loads without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system. 2. Breakaway walls shall have a design safe loading resistance of not less than ten (10) and no more than twenty (20) pounds per square foot. 3. The use of breakaway walls that exceed a design safe loading resistance of twenty (20) pounds per square foot may be permitted only if a professional engineer or architect licensed by the Commonwealth of Virginia certifies that the designs proposed meet the following conditions: a. Breakaway wall collapse shall result from water load less than that which would occur during the base flood; and b. The elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement, or other structural damage due to the effects of wind and water loads acting simultaneously on all building components (structural and nonstructural). Water loading values shall be those associated with the base flood elevation on the FIRMs. Wind loading values shall be those required by the Virginia Uniform Statewide Building Code (VA USBC). F. The enclosed space below the lowest floor shall be used solely for parking of vehicles, building access, or storage. Such space shall not be partitioned into multiple rooms, temperature-controlled, or used for human habitation. G. The use of fill for structural support of buildings is prohibited. When non-structural fill is proposed in a coastal high hazard area, appropriate engineering analyses shall be conducted to evaluate the impacts of the fill prior to issuance of a development permit. H. Existing nonconforming uses and structures located below the level of the base flood elevation, as shown in the FIS and accompanying FIRMs, shall not be expanded. I. Sand dunes, barrier beaches, and other natural protective barriers shall remain intact to provide protection against wind, waves, and erosion drainage. Any person who desires to use or alter any coastal primary sand dune or beaches, other than for the purpose of conducting the activities specified in Article 1600, Section 1602 of the Zoning Ordinance of the City of Virginia Beach, shall first obtain a permit, or authorization, from the USACE, VADEQ, the Virginia Marine Resources Commission, and the Wetlands Board through the joint permit application process. J. Manufactured homes are prohibited.
(Ord. No. 3309, 11-26-13; Ord. No. 3376, 10-7-14; Ord. No. 3417, 6-2-15; Ord. No. 3685, 2-1-22)
Ask a question about Virginia Beach law
Corpus searches the Virginia Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.