For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8 — Design criteria

Code of the City of Virginia Beach, Virginia (Supp. No. 170: codified through Ordinance No. 3872, adopted September 1, 2026) · Virginia Beach City Code, App. G, § 8

Corpus is an independent public-information project, not the official City of Virginia Beach website. Stable reference: corpuslaw.us/code/66446ac7-3482-484e-b451-37fee0b63aae

Sec. 8. - Design criteria.

In order to ensure that the objectives of this ordinance and the performance standards set forth hereinabove will be attained, development subject to the provisions of section 7(e) shall be in accordance with the following requirements, which shall be in addition to the requirements of subsections (a), (b), (c) and (d) of section 7: (a) Channeling runoff directly into water bodies shall be prohibited; and stormwater runoff shall be routed through systems designed to increase time of concentration, decrease velocity, increase infiltration, allow suspended solids to settle and remove pollutants; (b) Watercourses shall not be dredged, cleared of vegetation, deepened, widened, straightened, stabilized or otherwise altered, except for the purpose of governmental flood control or water quality projects or normal maintenance. Maintenance of such watercourses shall be in accordance with the erosion and sediment control requirements of sections 30-56 through 30-78 of the City Code; (c) Water shall be retained or detained before it enters any watercourse in order to prevent siltation or other pollution; (d) Streambank erosion control shall be designed so as to meet or exceed the minimum state stormwater management criteria, which require that stormwater runoff be discharged into a channel which conveys runoff from a two-year storm event without flooding or erosion; (e) The area of land disturbed by development shall be as small as practicable. Those areas which are not to be disturbed shall be protected from construction activity by adequate barriers. Whenever practicable, existing vegetation shall be retained and protected on the development site; (f) Wetlands and watercourses shall not be used as sediment traps; (g) Erosion and sedimentation facilities shall receive maintenance as prescribed by the approved management plan required by section 9 of this ordinance; (h) Artificial watercourses shall be designed to reflect the degree of erodibility of soil types through which such watercourses are constructed and to result in flow velocities sufficiently low to prevent erosion of the banks or bed of such watercourses; (i) Stormwater management ponds shall be used to detain or retain the increased and accelerated runoff generated by development and shall remove pollutants in stormwater to the maximum extent practicable. Water shall be released from detention pond into watercourse or wetlands at a rate and in a manner approximating the natural flow which would have occurred before development; (j) The use of wetlands for storing and purifying water may be used as the final treatment as part of a comprehensive stormwater management plan, provided their capacity is not overloaded, thereby harming the wetlands and transitional vegetation. Wetlands shall not be damaged by the construction of stormwater management systems; (k) Structural best management practice (BMP) facilities shall not be used as sediment traps during construction unless so designed and approved in accordance with the construction plans; (l) No structural best management practice (BMP) facility shall be constructed within a special flood hazard area; (m) The use of multiple best management practice (BMP) facilities, both structural and nonstructural, is encouraged; (n) Stormwater management facilities incorporating the following design criteria are encouraged: (1) Retention areas should be designed so that maintenance necessitated from siltation deposition is easily achieved. Forebay areas should be constructed at each stormwater inflow site, and an emergent wetlands bench should be established around the forebay perimeter; (2) Retention areas should include an emergent wetlands bench area around the perimeter of the facility. Shorelines shall be designed so that benched areas are winding rather than straight, thereby maximizing the length of shoreline and offering more space for the growth of emergent vegetation; (3) Retention areas and borrow pit operations should be designed to include a dewatering facility to capture all sediment; (4) Maintenance access routes should be provided to all structural best management practice (BMP) facilities; (5) Retention area facilities should include the planting of grasses and herbaceous and woody vegetation along the perimeter of such facilities to improve aesthetics and below the top of bank to promote water quality improvement; and (6) Infiltration facilities should not be located under areas of impervious cover without design provisions for their long term inspection and maintenance of the infiltrative function of the facility as approved by the director of planning, public works, or in the case of water and sewer facilities, public utilities, as the case may be; and (o) Stormwater, wastewater and potable water supply facilities and facilities used for the underground storage of petroleum products shall be designed and located so as to optimize water quality benefits while protecting potable water supplies.

(Ord. No. 2673, 10-23-01; Ord. No. 3315, 11-26-13; Ord. No. 3342, 4-22-14, eff. 7-1-14)

Ask a question about Virginia Beach law

Corpus searches the Virginia Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.