§ 3204 — Outdoor Lighting
Code of Ordinances of the City of Montpelier, Vermont (Codified through Ordinace No. 2026-0413, adopted April 8, 2026. (Supp. No. 2, Update 1)) · Montpelier Code of Ordinances § 3204
Corpus is an independent public-information project, not the official City of Montpelier website. Stable reference: corpuslaw.us/code/89ff1020-890c-4a27-8ecb-27622f7561c5
Section 3204. - Outdoor Lighting
3204.A Purpose. Outdoor lighting shall be regulated to reduce its obtrusive and disruptive aspects, and shall be limited to the minimum necessary for safety, security, and nighttime use of property. It is the intent of this section to maintain a dark night sky and reduce light trespass, glare, and energy use by encouraging lighting designs that direct appropriate amounts of light where and when it is needed, increasing the use of energy efficient lamps, and discouraging the use of poorly shielded or directed light fixtures. 3204.B Applicability. All outdoor lighting shall be installed in accordance with the provisions of this section except for: (1) Streetlights. (2) Decorative holiday lighting using low-wattage lamps that is illuminated for no more than 90 days in any calendar year. (3) Outdoor lighting incidental to permitted construction or the maintenance, repair or construction of public facilities or infrastructure, or to work conducted in the public interest such as law enforcement or emergency response. 3204.C Lighting Plans. Applications for major site plan approval shall include a lighting plan prepared by a qualified professional lighting designer or engineer. 3204.D Previously Developed Sites. When changes to existing outdoor lighting are proposed on a site with nonconforming lighting, the applicant shall bring all similar lighting (e.g. all parking lot lighting), including any previously installed and proposed new outdoor lighting, into conformance with this section. 3204.E Lighting Classes and Zones. This section regulates outdoor lighting based on the following classes and zones: (1) Class 1 Lighting includes all outdoor lighting used for outdoor dining or food service areas, outdoor assembly or maintenance facilities where regularly scheduled work activities occur after dark, display areas, assembly areas like amphitheaters, recreational facilities, signs or similar applications where color rendition is essential to the illuminated activity or purpose of the lighting. (2) Class 2 Lighting includes all outdoor lighting used for illumination of walkways, roadways, equipment yards, parking lots, outdoor security, or similar applications where general illumination for visibility, safety, or security of the grounds is the primary concern. (3) Class 3 Lighting includes all outdoor lighting used for decorative effects such as architectural illumination, flag and monument lighting, landscape lighting and similar applications. (4) Lighting Zone 1 encompasses the Mixed Use Residential, Residential 1500, Residential 3000, Residential 6000, Residential 9000, Rural and Municipal zoning districts. (5) Lighting Zone 2 encompasses the Urban Center 1, Urban Center 2, Urban Center 3, Urban Residential, Riverfront, Eastern Gateway, and Western Gateway zoning districts. 3204.F General Standards. All outdoor lighting shall be kept to the minimum required for safety, security, and the intended use in accordance with the following: (1) Shielding. All nonexempt outdoor light fixtures shall be shielded as specified in Figure 3-21. All fixtures that are required to be fully shielded shall be installed and maintained in such a manner that the shielding is effective. (2) Total Output. Total output from all nonexempt outdoor light fixtures on a site shall not exceed the limits specified in Figure 3-22. (3) Uniformity. Outdoor lighting shall be designed to provide a uniform distribution of light in areas regularly traversed by vehicles or pedestrians. Lower light levels with more uniformity provide safer and more efficient lighting than higher light levels with less uniformity. Lighting plans that produce a ratio of 3:1 or less between the highest light level and lowest light level within a trafficked area on the site are strongly encouraged and ratios in excess of 10:1 are strongly discouraged. (4) Allowed Lamp Types. All lamps shall conform to the types specified in Figure 3-21 and shall be LED lamps or Energy Star certified. (5) Spot Light Aiming. Light fixtures containing spot or flood lamps: (a) Shall be aimed no higher than 45° above straight down. (b) Shall be considered fully shielded when aimed straight down. (c) Shall be considered partially shielded when aimed above straight down. (d) With high-intensity light output are discouraged. (6) Light Trespass. Any outdoor light fixture containing a lamp with an initial output of more than 10,000 lumens that will be located within 50 feet of residential property or a public right-of-way shall use an internal or external "house side" shield. The light fixture and shield shall be oriented to minimize light trespass over the adjacent property or right-of-way. (7) Freestanding Lights. Freestanding light fixtures: (a) Shall not exceed 25 feet in height. (b) Should not be more than 12 feet in height when used to light walkways and other pedestrian-oriented spaces. (c) May be located within front setbacks. (d) Shall be set back from side and rear property lines at least a distance equal to their height except if located within a shared parking or loading area, or if the adjoining properties are commonly owned. (8) Internally Illuminated Architecture. The initial lamp output of any architectural element (ex. wall, fascia or canopy edge) that is internally illuminated and that is not a sign shall be considered partially shielded, Class 3 lighting. (9) Luminous Tube Lighting. Luminous tube lighting does not require shielding but it shall be considered partially shielded lighting for the purposes of calculating total outdoor light output for the site. (10) Indoor Lighting. Any indoor light fixture within a non-residential structure containing a lamp with an initial output of 2,000 lumens or more that is mounted such that any part of the fixture is lower than the height of a window or door shall be fully shielded. (11) Time Limits. The Development Review Board may limit when outdoor lighting may be used as deemed necessary to achieve the purposes of this section and protect the character of the neighborhood. Use of timers, dimmers, and sensors is encouraged. 3204.G Special Use Lighting. There are special standards for the following uses: (1) Recreation Facilities. Lighting for outdoor recreation facilities: (a) Shall be considered Class 1 Lighting and shall be exempt from the lumens per acre limit specified in Figure 3-22. (b) Shall be designed to achieve no greater than the minimal levels for the activity as recommended by the Illuminating Engineering Society of North America (IESNA). (c) Shall use fixtures that are fully shielded or use internal or external louvers or shields to minimize off-site glare and light trespass. (d) Shall use fixtures that are installed and maintained with aiming angles that permit no greater than 5% of the light emitted by each fixture to project above the horizontal. (e) Shall be extinguished within 30 minutes of the cessation of play. (f) Shall not be illuminated after 11 p.m. Illumination of the facility shall be permitted after 11 p.m. only to conclude a scheduled event that did not conclude before the time limit due to unusual circumstances. (2) Frontage Row of Vehicle Display Areas. Lighting for the frontage row of vehicle display areas shall be considered Class 1 Lighting and shall conform to the following: (a) All frontage row vehicle display area lighting shall use properly installed and maintained fully shielded light fixtures. (b) The total outdoor light output for the frontage row of vehicle display areas shall be exempt from the lumens per acre limit specified in Figure 3-22, but shall not exceed 60 lumens per square foot. (c) Any frontage row of vehicle display light that exceeds the lumens per acre limit specified in Figure 3-22 shall be turned off after 9 p.m., or 30 minutes after the close of business if later. (d) Lighting for the frontage row of vehicle display areas remaining on after the time limit shall be considered Class 2 Lighting and shall conform to the standards of Subsection 3204.F. (3) Fueling Station Canopies. Lighting for fueling station canopies shall be considered Class 1 Lighting and shall conform to the following: (a) All light fixtures mounted on or recessed into the lower surface of fueling station canopies shall be fully shielded and use flat lenses. (b) The total light output used for illuminating fueling station canopies shall not exceed 60 lumens per square foot of canopy. (c) The total light output used for illuminating fueling station canopies shall be counted towards the site's lumens per acre limit as specified in Figure 3-22. 3204.H Security Lighting. The Development Review Board may approve security lighting in accordance with the following: (1) No provision of this section shall be interpreted to prohibit the minimum security lighting required to meet state or federal code. (2) The use of timers and sensors to automatically activate and deactivate security lighting is strongly encouraged. Figure 3-21. Light Fixture Shielding and Lamp Type ZONE 1 | ZONE 2 | LAMP TYPE CLASS 1 LIGHTING Initial output <2,000 lumens | Fully shielded | Partially shielded | All types Initial output 2,000 lumens or more | Fully shielded | Fully shielded | All types CLASS 2 LIGHTING Initial output <2,000 lumens | Fully shielded | Partially shielded | All types Initial output 2,000 lumens or more | Fully shielded | Fully shielded | "warm white" LED High-pressure sodium Low-pressure sodium CLASS 3 LIGHTING Initial output <2,000 lumens | Partially shielded | Partially shielded | All types Initial output 2,000 lumens or more | Prohibited | Prohibited | - Figure 3-22. Total Outdoor Light Outputs ZONE 1 | ZONE 2 Commercial, Industrial or Mixed Use Max of all fully shielded light fixtures | 50,000 lumens/acre | 100,000 lumens/acre Max of all partially shielded light fixtures | 5,000 lumens/acre | 10,000 lumens/acre Multi-Unit Residential Max of all fully shielded light fixtures | 10,000 lumens/dwelling | 10,000 lumens/dwelling Max of all partially shielded light fixtures | 3,000 lumens/dwelling | 3,000 lumens/dwelling
Ask a question about Montpelier law
Corpus searches the Montpelier sections it holds and shows the ones that match, with their citations. Free, no sign-in.
