For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3401 — General Planned Unit Development

Code of Ordinances of the City of Montpelier, Vermont (Codified through Ordinace No. 2026-0413, adopted April 8, 2026. (Supp. No. 2, Update 1)) · Montpelier Code of Ordinances § 3401

Corpus is an independent public-information project, not the official City of Montpelier website. Stable reference: corpuslaw.us/code/b6941358-59b2-4c83-885c-bdc1fa791357

Section 3401. - General Planned Unit Development

3401.A Purpose. The purpose of this section is to allow flexibility in the site and parcel layout, placement and clustering of buildings, use of open space, and related site and design considerations that will best achieve the goals for the area as articulated in these regulations and the City Plan. Further this section is intended to facilitate the efficient and economical provision of public facilities and infrastructure as well as avoiding hazardous development areas and protecting natural resources. 3401.B Applicability. The provisions of this section apply to clustered parcel subdivisions, where certain parcel and structural dimensional standards are less than the minimum required but for which no density bonuses nor use considerations are needed. (1) General PUDs are allowed in any zoning district. (2) To be eligible for a General PUD the parcel must be a minimum of at least three times the minimum parcel size allowed in the zoning district. (3) General PUDs will typically individually provide most or all features of a standard parcel including private driveway, parking spaces, accessory structures, and private yards. 3401.C Application Rules. In addition to the materials presented for subdivision plat approval, the applicant shall submit the following information: (1) A statement setting forth all proposed modifications to dimensional standards. (2) A statement explaining how common land and any shared utilities and facilities will be managed. (a) If condominium association documents are provided then relevant provisions shall be identified and explained. (3) A statement explaining how any unused density is to be allocated between the parcels or if it will be owned in common under an association. (4) A statement explaining what mechanism will be used to prevent development of lands that are proposed for conservation or to otherwise remain undeveloped. (5) A site plan identifying the locations of any natural resources and hazardous areas that are shown on the Natural Resources Inventory Map, river hazards as defined by the River Hazard Area Regulations, and the location of steep slopes on the Slopes Map. 3401.D Administration Rules. General PUDs will follow the subdivision and PUD procedure rules outlined in Chapter 440. 3401.E Density. There are no density bonuses for a General PUD. The maximum number of parcels or units is the same as the maximum number of possible parcels or units as could be created in a standard subdivision. 3401.F Use Standards. The uses allowed within a General PUD shall be as established in the underlying zoning district. 3401.G Dimensional Standards. The following rules apply to any proposed modification to dimensional standards. (1) The following dimensional requirements may be varied by the Board for parcels within a General PUD with the following limitations: (a) Parcel size. The smallest parcel size cannot be less than 3000 square feet. (b) Frontage. Not less than 20 feet for parcels accessed by a shared driveway and not less than 40 feet for other parcels. (c) Coverage. While coverage requirements may be modified for individual parcels within the PUD, the coverage requirement must be met overall for the entire PUD. (d) Front, Side, and Rear setbacks (primary and accessory structures). While the identified setbacks may be modified for individual parcels within the PUD, setbacks shall be maintained at the periphery of the development. (e) Height requirements (primary and accessory). The maximum building height may be increased by up to 10 feet above the district or accessory standard. (2) All varied dimensional requirements shall run with the lifetime of the PUD. (3) Building footprint may be waived for buildings in a General PUD through Section 3002.J. 3401.H Management of residual density. The development shall establish a process by which unused development potential is owned and managed. For example, if a General PUD uses only 8 of 10 possible dwelling units, how will a future application to add an additional dwelling unit or parcel be addressed by the members of the PUD? Options could include: (1) If a Homeowners Association is present the Association could be assigned to manage any remaining development potential. (2) The units could be assigned to specific parcels within the subdivision. 3401.I Undeveloped parcels. When a General PUD creates a parcel where no development is allowed (e.g. for conservation purposes, common recreation land, etc.) a mechanism shall be in place to ensure no future development is allowed. Options could include: (1) A legal instrument such as a covenant, easement, or provisions of a Homeowners Association could outline the development limitations. (2) The parcel could be sold to a third party conservation organization. (3) The parcel could be clearly labeled such on the final plat. 3401.J Natural Resources and Hazardous Areas. The development shall be a safe and effective treatment of the site. (1) The clustering of parcels shall first avoid all features identified on the Natural Resources Inventory Map including rare natural communities, vernal pools, wetlands and streams. (2) The clustering of parcels shall identify a portion of every parcel that may safely be developed under the River Hazard Area regulations. (3) The clustering of parcels shall minimize the impacts on steep slopes when considering the reasonable future development of the parcels.

Ask a question about Montpelier law

Corpus searches the Montpelier sections it holds and shows the ones that match, with their citations. Free, no sign-in.